HomeMy WebLinkAboutR-276507STORMWATER DRAINAGE PNOTES:1. BEFORE ANY CONSTRUCTION MENT ACTIVITY OCCURS, A PRECONSTRUCTION GRADING AND STORM DRAINAGE PLAN
MEETING MUST BE HELD WITH THE CITY OF RENTON DEPARTMENT OF PUBLIC WORKS,
DESIGN ENGINEER. A PORTION OF SOUTHWEST 1/4 OF SOUTHWEST1//4, SECTION 3, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M.
2. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE "1988RUCTI STANDARD CITY OF RENTION, KING COUNTY, WASHINGTON
SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION" PREPARED BY CITY �
WSDOT AND THE AMERICAN PUBLIC WORKS ASSOCIATIONS (APWA), AS AMENDED BY
THE CITY OF RENTON DEPARTMENT OF PUBLIC WORKS.
3. THE STORM DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO THE APPROVED
PLANS WHICH ARE ON FILE IN THE DEPARTMENT OF PUBLIC WORKS. ANY DEVIATION
FROM THE APPROVED PLANS WILL REQUIRE WRITTEN APPROVAL FROM THE CITY OF
RENTON DEPARTMENT OF PUBLIC WORKS, DESIGN ENGINEER OR STORM WATER UTILITY.
4. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER
CONSTRUCTION IS IN PROGRESS.
5. DATUM SHALL BE U.S.G.S UNLESS OTHERWISE APPROVED BY CITY OF RENTON
DEPARTMENT OF PUBLIC WORKS. REFERENCE BENCHMARK AND ELEVATION ARE NOTED
ON THE PLANS.
6. ALL SEDIMENTATION/EROSION FACILITIES MUST BE IN OPERATION PRIOR TO CLEARING
AND BUILDING CONSTRUCTION, AND THEY MUST BE SATISFACTORILY MAINTAINED UNTIL
CONSTRUCTION IS COMPLETED AND THE POTENTIAL FOR ON -SITE EROSION HAS PASSED.
7. ALL RETENTION/DETENTION FACILITIES MUST BE INSTALLED AND IN OPERATION PRIOR TO
OR IN CONJUNCTION WITH ALL CONSTRUCTION ACTIVITY UNLESS OTHERWISE APPROVED
BY THE DEPARTMENT OF PUBLIC WORKS, STORM WATER UTILITY.
8. GRASS SEED MAY BE APPLIED BY HYDROSEEDING. THE GRASS SEED MIXTURE, OTHER
THAN CITY OF RENTON APPROVED STANDARD MIXES, SHALL BE SUBMITTED BY A
LANDSCAPE ARCHITECT AND APPROVED BY THE DEPARTMENT OF PUBLIC WORKS, STORM
WATER UTILITY.
9 ALL PIPE AND APPURTENANCES SHALL
HA BE LAID ON A PR
OPERLY PREPARE FOUNDATION
IN ACCORDANCE WITH SECTION 7-02.3(1) OF THE CURRENT STATE OF WASHINGTON
STANDARD SPECIFICATION FOR ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE
NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION
MATERIAL AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL
TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON
A UNIFORMLY DENSE UNYIELDING BASE. ALL PIPE BEDDING SHALL BE APWA CLASS "C,"
WITH THE EXCEPTION OF PVC PIPE. ALL TRENCH BACKFILL SHALL BE COMPACTED TO
MINIMUM 95 PERCENT FOR PAVEMENT AND STRUCTURAL FILL AND 90 PERCENT
OTHERWISE PER ASTM D-1557-70. PEA GRAVEL BEDDING SHALL BE 6 INCHES AND OVER
AND UNDER PVC PIPE.
10. GALVANIZED STEEL PIPE AND ALUMINIZED STEEL PIPE FOR ALL DRAINAGE FACILITIES
SHALL HAVE ASPHALT TREATMENT #1 OR BETTER INSIDE AND OUTSIDE.
11. STRUCTURES SHALL NOT BE PERMITTED WITHIN 10 FEET OF THE SPRING LINE OF ANY
STORM DRAINAGE PIPE, OR 15 FEET FROM THE TOP OF ANY CHANNEL BANK.
12. ALL CATCH BASIN GRATES SHALL BE DEPRESSED 0.10 FEET BELOW PAVEMENT LEVEL.
13. OPEN CUT ROAD CROSSINGS AND EXISTING PUBLIC RIGHT-OF-WAY WILL. NOT BE
ALLOWED UNLESS SPECIFICALLY APPROVED BY CITY OF RENTON DEPARTMENT OF PUBLIC
WORKS, DESIGN ENGINEER.
14. ROCK FOR EROSION PROTECTION OF ROADSIDE DITCHES, WHERE REQUIRED, SHALL BE
OF SOUND QUARRY ROCK PLACED TO A DEPTH OF 1 FOOT AND MUST MEET THE
FOLLOWING SPECIFICATIONS: 4 INCHES TO 8 INCHES/40 PERCENT TO 70 PERCENT
PASSING; 2 INCHES TO 4 INCHES ROCK/30 PERCENT TO 40 PERCENT PASSING; AND -2
INCHES ROCK/10 PERCENT TO 20 PERCENT PASSING.
15. ALL BUILDING DOWNSPOUTS AND FOOTING DRAINS SHALL BE CONNECTED TO THE
STORM DRAINAGE SYSTEM UNLESS APPROVED BY THE DEPARTMENT OF PUBLIC WORKS,
DESIGN ENGINEER OR STORMWATER UTILITY. AN ACCURATELY DIMENSIONED CERTIFIED
AS -BUILT DRAWING OF THIS DRAINAGE SYSTEM WILL BE SUBMITTED TO THE CITY OF
RENTON UPON COMPLETION.
16. ISSUANCE OF THE BUILDING OR CONSTRUCTION PERMIT BY THE CITY OF RENTON DOES
NOT RELIEVE THE OWNER OF THE CONTINUING LEGAL OBLIGATION AND/OR LIABILITY
CONNECTED WITH STORM SURFACE WATER DISPOSITION. FURTHER, THE CITY OF
RENTON DOES NOT ACCEPT ANY OBLIGATION FOR THE PROPER FUNCTIONING AND
MAINTENANCE OF THE SYSTEM PROVIDED DURING CONSTRUCTION.
17. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE SAFEGUARD,
SAFETY DEVICES, PROTECTIVE EQUIPMENT, FLAGGERS, AND ANY OTHER NEEDED
ACTIONS TO PROTECT THE LIFT, HEALTH, AND SAFETY OF THE PUBLIC, AND TO PROTECT
PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK COVERED BY THE
CONTRACT. ANY WORK WITHIN THE TRAVELED RIGHT-OF-WAY THAT MAY INTERRUPT ..
NORMAL TRAFFIC FLOW SHALL REQUIRE AN APPROVED TRAFFIC CONTROL PLAN BY THE
TRAFFIC ENGINEERING DIVISION OF THE DEPARTMENT OF PUBLIC WORKS. ALL SECTIONS
OF THE WSDOT STANDARD SPECIFICATIONS 1-07.23, TRAFFIC CONTROL, SHALL APPLY.
18. SPECIAL DRAINAGE MEASURES WILL BE REQUIRED IF THE PROJECT LOCATION IS WITHIN
THE AQUIFER PROTECTION AREA.
STORM DRAINAGE PIPE SPECIFICATIONS
ALL STORM DRAIN PIPE MAY BE CONSTRUCTED OF ONE OF THE FOLLOWING MATERIALS UNLESS
OTHERWISE SPECIFIED IN THE PLANS. ALL PIPE JOINTS MUST BE GASKETED WATERTIGHT AND
MUST BE OF THE SAME MATERIAL AS THE PIPE. ALL PIPE SHALL HAVE A MINIMUM COVER AS
SPECIFIED AND SHALL BE ADEQUATELY PROTECTED DURING CONSTRUCTION (REFER TO THE
MANUFACTURER'S RECOMMENDATIONS FOR MINIMUM COVER FOR HEAVY EQUIPMENT LOADINGS).
A. DUCTILE IRON - 4 INCH THROUGH 14 INCH DIAMETER PIPE SHALL BE CLASS 52 AND 16-INCH
THROUGH 24-INCH DIAMETER PIPE SHALL BE CLASS 50, ALL IN ACCORDANCE WITH USA
STANDARD A-21.1 (AWWA C-51). ALL JOINTS SHALL BE PUSH -ON, MECHANICAL, OR
FLANGED (6-INCH MINIMUM COVER).
B. CONCRETE - 4 INCH THROUGH 18 INCH DIAMETER PIPE SHALL BE NON -REINFORCED, BELL AND
SPIGOT WITH RUBBER GASKET JOINTS, CONFORMING TO ASTM C-4 (CLASS 11). 21 INCH
THROUGH 36 INCH DIAMETER PIPE SHALL BE REINFORCED, BELL AND SPIGOT WITH RUBBER
GASKET JOINTS, CONFORMING TO ASTM C-76 (2 FOOT MINIMUM COVER).
C. PVC - 4 INCH THROUGH 18 INCH DIAMETER PIPE, WITH 24-INCH TO 36-INCH OF COVER SHALL
BE IN ACCORDANCE WITH ASTM D3034 SDR 21. 4-INCH THROUGH 18-INCH DIAMETER PIPE,
WITH ASTM D3034 SDR 35 SHALL HAVE 36-INCH MINIMUM COVER. ALL JOINTS SHALL BE
PUSH -ON WITH RUBBER GASKETS. PVC STORM PIPE REQUIRES A.C. COLLARS (I.E., CATCH
BASIN CONNECTION) OR KOR-N-SEAL CONCRETE BOOTS.
D. HELICAL CORRUGATED PLAIN ALUMINUM PIPE (CMP) - 6 INCH THROUGH 18 INCH DIAMETER
PIPE SHALL BE 16 GAUGE WITH 2 2/3 INCH X 1/2 INCH CORRUGATIONS. 21 INCH THROUGH
36 INCH DIAMETER PIPE SHALL BE 14 GAUGE WITH 2 1/3 INCH X 1/2 INCH CORRUGATIONS.
REFER TO DETAILS IN THESE PLANS FOR ANY PIPES LARGER THAN 36 INCH DIAMETER. ALL
ALUMINIZED PIPE SHALL HAVE ASPHALT TREATMENT 1 COATING (2.0-FOOT MINIMUM COVER).
E. HELICAL CORRUGATED STEEL PIPE (HCMP) - 6 INCH THROUGH 36 INCH SHALL BE 16 GAUGE
WITH 2 2/3 INCH X 1/2 INCH CORRUGATIONS. ALL STEEL MATERIALS SHALL BE GALVANIZED
AND ASPHALT TREATMENT " COATED. REFER 10 DETAILS IN THESE PLANS FOR ANY PIPES
LARGER THAN 36 INCHES IN DIAMETER (2.0-FOOT MINIMUM COVER).
F. CORRUGATED POLYETHELENE MEETING THE REQUIREMENTS OF AASHTO M-294, TYPE S. MINIMUM
PIPE DIAMETER SHALL BE 8". MAXIMUM PIPE DIAMETER SHALL BE 36" OR THE DIAMETER FOR
WHICH THE SUPPLIER HAS A JOINT CONFORMING TO ASTM D 3212, WHICHEVER IS LESS. JOINTS
SHALL BE CLASSIFIED AS "WATERTIGHT". WATERTIGHT JOINTS SHALL BE MADE WITH A SLEEVE
OR WITH A BELL SPIGOT AND SHALL CONFORM TO ASTM D 3212 (10.8 PSI) USING ELASTOMERIC
GASKETS CONFORMING TO ASTM F 477. GASKETED JOINTS SHALL BE LUBRICATED AS RECOMMENDED
BY THE PRODUCER DURING INSTALLATION. SOILTIGHT" JOINTS SHALL NOT BE PERMITTED.
FITTINGS SHALL BE BLOW MOLDED, ROTATIONAL MOLDED, OR FACTORY WELDED. THERMOPLASTIC
PIPE FITTINGS SHALL MEET THE REQUIREMENTS SET FORTH IN AASHTO M 294.
7VD- fro -. ?&r
,TAT ION !NG 11- A'
HIX BF UIS B 4J
I
ME AND x unn N
o+uG I� I
Ili
Ii I) I
I ; ! 393.78.
I _ 7t l�- - at
IE=39C.17(8" PVC E) � I: 12 DD .` !��f
E. 389.57(8" CONC W) \ myi E
EXISTING CB °
�iIM 393 55 I
CONC E: , j
Lk2
I.--
EXIS-NG MON. WELL---_ I_.„�_
ll 1 it
EX611NG j' II ^I
POWER VAULT l-,
.HT � BOX
RE. HYDRANT
N0 WAT R VALVE
EXISTING CB-O--\ III
RIM=394.82 II
Ih=369,0908" CONC N)
E=331 7 \II
IE=384.06 -
"X S ING S:Aa-0
Pofid 3 77
le-SSo..,I 8 GJNC- -/
!E:=386.91W, PVC W) v 1
TVUNC BRASS NAIL -
W/PUNC.H SET' 'N
A 4 CONC. MOT7. `
A CASE
EX!S: SSMhi-i:
RIM=395.43
IE-366.82(8` CONC Sl
F 38c 96(8' VVC SE)
IE.4.,7 _S8 -VC SW')
� ,3653;8 CGNC ^I7
EXISTING -
TEL_PI10NE _„
MANHOLE ff
EXISTING ,.GHT J BOX -
ANE, LJM NA'RE
E'XIS N., WATER VALVE..
-Xis'ING DHH B
E=4,8 a 5
E 8H 89(7 CONC N)
IL-38999ti8" 14-
L-3904e(5 CM 1N)
Ex StN CS-1-
RIM 954-
E 39CMP E)
'E=38 6 2 CMP NW)
Chip'
IE=_9�..
j j9U
EXISTING SSMY,-A
R161 -395.' 7
IE=385.6I:(8..
1E=39-13i8" CGNC S,
EXISTING SDIIAH-A
RIM=394.93
,E= 89 G(18" CGNC S'
IE=389.00f18" CGNC
_
EXISTING CB-B
IE=390.46(24` CAP NW)
1
IE=393.G1 a" CMP)
iI
IE CB #5'TYPE 1" S)
1�I Exls�Nc
Jj PAVEMENT
1�5 938'55" E 704
L - M4.71 394.W�
5 70A
i
�A-z-.336--I •.. CB
.&rl_F 12' SO @ .9%-
5 LF 12'SO@1.0%
EXIST'f4G
CHAIN LINK
FENCE
-EX!S-NG 36- CA?
MEASURED 'di,iH TAPE !E=388.311 i!
EXISTING cONC WALL
IV! CHAIN LINK FOA.E
-EXISTING 35 CMIE 39'.84(TOP)
?A.ASUREJ WITH. TAPE =38B.8-`.E)
-EXISTING 2 ' DRAINAGE
EASEAENT (PER SHORT
PLAT)
- IE=389.25
CB P. TYPE 2-54"
SIDEWALK DRIVEWAY OR ALLEY
�g EXPANSION JOINTS
SEE NOTE 2
3/8"JOINTS SIDN 2b?o yp Lk @ 4' xw�k
SEE NOTE 2 3
SEE NOTE I A�i SIDEWALK Im, wwiii nn
ALTERNATE 1 CURB AND GUTTER
A`v SEE DETAIL "A
" SHOWN HOWEVER,
WHEN THERE IS A PLANTING STRIP OTHER CURBS MAY
10' EXPANSION JOINT SE USED (SEE SECTION A -A
STANDARD PLANS)
3/8" E%PANSION
JOINTS
SEE NOTE 2 DRIVEWAY OR ALLEY
�1 SCORE LINEx
A
3/6" EXPANSION �$ �^� DETAIL A
JIDNTS SEE NOTE 1
SEE NOTE APPROACH WITH
2
s SIDEWALK MONOLITHIC CURB
SEE NOTE 5
A
ALTERNATE 2
WEN SIDEWALK IS NEXT TO CURB
NOTFi CEMENT CONCRETE DRNEN'AY
L DUN- JOINTS SHALL HE PLACED NOT TO EXCEED 15' C/C NOR LESS THAN 10' C/C. THEY SHALL OR ALLEY APPROACH
NET BE LESS THAN 3/16" IN THICKNESS AND SHALL EXTEND 2-1/4" DEEP.
Z V/ THRU JOWTS SHALL BE PLACED AT HACK, SIDES AND FRONT (BEHIND CURB) OF APPROACH.
3. CEMENT NSHALL BE CLASS 30D0 AIR ENTRAINED airp JOINTS
SHALL
AD Leo
4. ALL JDTS SHALL CLEANED AND EDGED. oe n
5. APPROACH STALL NOTT BE POURED INTEGRAL WITH CURB AND GUTTER, BUT MAY BE POURED
SN GRAL WITH EM STANDARD CURB (SEE DETAIL "A") PROCTOR.
6. SUHGRADE [@PACTIDN SHALL HE 95% MODIFIED PROCTOR.
GATE REVI8i0N HY pppR DWG. NAME. M01N SP PAGE: FOOS
INSTALL 86 LF TRENCH
DRAIN PER DETAIL THIS
SHEET.
x
s➢
l
I
93 LF 6' DIA CMP
DETENTION PIPE
-
SEE SHEET C5
SLOPE FLOOF
p
TRENCH DRAI
TO 6" OUTLE
39t,
2, TYPE 2-54"
SEE SHT C5 FOR
DETAILS
13 LF 6" DI ® 0.50%
-
18.9 ,
LF 12" DI 0
I
CB 3, TYPE 1
E�97 12') 9.16 (N 8 W)
C56, ° O 9Q
TYPE 11`
34:38' 39�35
1-W 391.49 02"
E)
-EX'S N!G L-EXSTNG WOGD
LAJRE FENCE
FUND REBAR HEjGE
C E
DI., JRBE::)
EXISTNG
RAILROAi T!E
PLANTER
-EX-SUNG
C'RIVENAY
-EX STINC
mml_R VALVE
!L
FORMED IN PLACE
TRENCH DRAIN DETAIL
0
Q
J
W
LL
LL
Z
O
U
W
Z
O
Ir
^W
J
z
III
0 Z
UW°'
Cn ® U
I-- Z Z
W � `<
IL <Q C
R _ U
CL co
O > F_
li 0 J o
W
m
rn
= C7 U
OzLd
3�
a�
X O ~
Q zw
j N u- 3 Z
476507Q 0CD 0 N � Z >
z Q D Do rl Zz
3U0ir �z
sLnN N Z Zv
m N Z N N
f y//
>�7/Y9 ?0 LL,
� Jy� Sb
dam,
Z
4 r
1t� 2
r:,T19 P� P. G,, i, y� `
�I�I�e pF WAS �vp� o CONS)
y 23975 p �� cr)
_i/ u®L T
EXPIRES 6-10-99 U
SCANNED MAY - 5 1999 1=0; (Q-276J`a� /*/ AC- a?6-rL'7 SCANNED NIAR 3 0 2000