Loading...
HomeMy WebLinkAboutW-295303A I B i C D _ E I F I G H I K RW '7 J � C i C7 N STATIC MIXER GS BYPASS FW L M N ' O P TW RW GAC BYPA FS N AIR C NC BACK PRESSURE I AIR T I SUSTAINING VALVE � FLO W CONTROL O M VALVES TW /BINS BOOSTER VENTURI PUMP M M 9 _ AIR EDUCTOR - ¢ FLUORIDE POLYPHOSPHRATE PUMP DEGASSER M M L v METERI CONTRO MG PUMPS METERIMG PUMPS VALVES ,( M M n (EXISTING) (EXISTING) M LJ T TW BS IN M M M M NO BLOWER fGAC -401 TM � (EXISTING) GS -411 `;J 7 8 M NC i M M I FW AERATION BOOSTS UMPS M M CCD TOWER (EXISTING) (EXISTING) TO 565 ZONE I �CE BINS FTW /FD ¢ M - AND 590 ZONE M z M Cn L7 7 U_ nGAC-402 m M Of m m —�� QM OVERFLOW AIR GAP P II M GS -412 4 M I FW ^ CLEARWELL M I M M OVERFLOW n (EXISTING) WELL 12 WELL 11 WELL 17 [ M TO SD 6 EXISTING BWS f FTW /FD CHLORINE CONTACT CHAMBER LOW—LIFT o ¢ PUMPS OCE RECHLORINATION o i '> NaOCI BREAKPOINT CHLORINATION n � _ M — GS -413 5 ST=DRAIN GAC -403 � � VENT 5 M FW —6 VENT HYPOCHLORITE o BWS FTW /FD DAY TANKS z O CE GREENSAND FILTERS GAC CONTACTORS 4 O AIR SCOUR SUPPLIER B WD BWW M M M BACKWASH HYPOCHLORITE 3 =2953A4 AIR GAP DISPOSAL PUMPS OVER CLE STORAGE T ANSOFERLPUIMPS METERING PUMPS BACKWASH HYPOCHLORITE SYSTEM RECYCLE PUMPS = AIR GAP EXISTING BOOSTER PUMP BUILDING NOTES: — CONSTRUCTION RECORD DRAWING NOTICE 1. THIS SCHEMATIC IS FOR ORIENTATION. FOR CLARITY, These record drawings have been prepared based upon 2 O n ^ information contained in addenda, change orders or 2 S OVERFLOW NOT ALL PIPING EQUIPMENT AND VALVES ARE SHOWN other ovailable construction information, and information - TO STORM DRAIN 2. SEE SHEET M1 FOR ABBREVIATIONS ON THIS DRAWING. provided by the Contractor, and by others. HDR has not BACKWASH BASIN verified the accuracy or completeness of the information SANITARY SEWER provided to it and does not warrant the accuracy or completeness of these record drawings. Users of this information shall be solely responsible to verify any and ` all information represented herein prior to any such use CITY L �i of the information. :� ,.� SURVEYED: — SCALE: — � CIT 1 OF REN ON DATE: JULY, 2003 ry DESIGNED: AF VERTICAL: NAVD 1988 =��' Planning /Building /Public Works Dept. ECONOMIC AND ENGINEERING e DRAWN: RB ONE INCH HORIZONTAL: NAD 1983/1991 Kennedy /Jenks PROJECT N0. SERVICES, INC. Or, 3-01-358 CHECKED: GP C6nsu tai tS MAPLE W..' —D - AT FULL SCALE 10900 NE 4TH STREET, SUITE 1110 WATER TREATMENT AND GOLF COURSE IMPROVEMENTS REVISION No. 32001 32nd Ave. S., Suite 100 BELLEVUE, WASHINGTON 98004 D APPROVED: IF NOT ONE INCH DATUM Federal Way, Washington 98001 C ISSUED FOR BID RB 7/03 GP SCALE ACCORDINGLY PORTLAND, OR / BELLEVUE, WA / KENNEWICK, WA / OLYMPIA, WA PROCESS FLOW SCHEMATIC DWG N0. DWG NQ. G2 N0. REVISION BY DATE APPR A B C D E F G H I J K L M N_ W- �C��3Af —i tb SCANNED OCT 2"2036 ROLL 21 0�_3- F-- 2�t'' -