Loading...
HomeMy WebLinkAboutD-333405M CALL 48 HOURS BEFORE YOU DIG �� \\ \ CV) �'. �' \ /�� WSD T BENCH RK 112 _ SEE SidE 2 - \ \ 1- 800 - 424 -5555 �y /'i O �\ \ v i EXISTING UTILITY LOCATIONS ARE APPROXIMATE, NOT ALL UTILTIES MAY BE SHOWN. CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL UTILITIES. SEE EROSION 2 DITCHES V Cj 0 < GENERAL NOTES: EX 8° DI WATER 0, \ A. MAIN STORM LINES MEASURED FROM CENTER OF STRUCTURES. SERVICE TO HYDRANT EX SDMH TYPE II ASBLT ,� `/ CBI 1, TYPE 1L i ,,a RIM EL = 10 RIM 110.61 b REMOVE EX CB B. CONTRACTOR SHALL INSTALL EROSION CONTROL, INCLUDING -67 ��� 1&REPLACE PLASTIC NE 20" IE= 0 NE 90,78 STOP LINE j EX` CB TYPE I �� d \ ?DISCHARGES FILTER FABRIC PROTECTION FOR DOWNSTREAM CATCHBASINS SW 21 IE= 8 _ S 9078 AS NEEDED SOMEWHERE RIM EL- 4.77 \ �, -� E 6" IE= 106. E 1b5.43 6° 111-k7 / ON SLOPE IN THE AREA. __,� __ -- ! �� RI -- 4. RIM 114.51 / --- '• -EjF�. (� - / r CA TION I 1 -A-- - 18'r_s`p - - -- r L 110.41 1 �- SSMH C. TRENCH PATCH SHALL BE PER CITY DETAIL HR -23 TYPICAL PATCH FOR FLEXIBLE PAVEMENT PERPENDICULAR TO ROAD CL. _ W 110.43 RIM 118.83 PR ECT / I _ - - -_ --_ I D. CONCRETE CURB, GUTTER, SIDEWALK SHALL BE PER CITY DETAILS, SHALL MATCH EXISTING. L °"-` _ CL CHAN104.74 /' ' AND SS MIT � ! SSMH / i ,,, ,�," �,, / / � '`- ��`7�° RIM EL= 84 // I -- / j 1 STOP \ // j' 10 SIGN / RESTORE CURB, SIDEWALK MP / GUTTER, SIDEWALK TYPE 2A GY�UTION POS B I ' / \ W THRUSBLOC _� ' _, ''� , ' = - / / 6 "u/ ❑ - �- -- - - - -- - - _ _ \ _ GRAVEL D 1�/EWAY -- -- -- -- -- - --- - -� -�- \ K � DO NOT LOCK \ - - - - - -- --- - - - - -- RIM 12"IE NE. S 12" IE =1 ' NORTH RIM 120.34 I 1 ; S 109.94-- - - - - -_ 120 / \ I --T15,38 W_ - -- r j S ABANDDN -C -17 - -- - - - - -- _ O 6' SIDE SEWER - �`JO 120 i - '- 2- Y _ /y / /N DRAWING NOTES: /•� Q I i I/� SCALE: 1 "= 1O� 1QRESTORE CURB, GUTTER, SIDEWALK AS NEEDED, MATCH EXISTING. i / PLUG EX SO IN CB ODl EX D H TYPE II -4$ \ o I RIM EL= 121.90 i 3 I ❑ N,S 1 ° IE =111.88 CORE DRILL CB FOR NEW SD PIPE. ® POTHOLE PRIOR TO START OF CONSTRUCTION. \ EXISTING STORM SYSTEM REFERENCE PLANS: R -1939 RENTON AVE S STREET IMPROVEMENT, APRIL 1983 I R -2239 WSDOR SR -405 TUKWILA TO SUNSET BLVD, AUG. 1990 TYPICAL TRENCH BEDDING AND BACKFILL (NTs) ........................_._. .........._......._............ . --- ---: --- --------- ---- ----- ----------------------------------- ------- ---- :- --------- -------_- - --- --- -------: -- ....... -------- :----------- --------- -------------------- --- ----- - ----- -- - -----..._............... ........:---------- ---- ---- -- ---...------------------------------------------------------------ ---------:-----------------:-..................:---.. ........----- ......--- --- --.... ----- -- ----- --- - -: ....................................... ....... ............................... SCALE = HORIZ: 1 "= 1V PROFILE ALONG NEW PIPE LINE = TRENCH: EXCAVATION VERT:= 1"= 5' POTHOLE GAS LOG ASBLT: GAS POTHOLED =1.5 Fr : PAY LIMIT 5' -0' MAXIMUM _ TO 1 FT BELOW NEW SO BELOW INVERT, NOT FOUND. - :SEE DETAIL:FOR PAVEMENT PATCH ..... ............... ...... -..... ..... ------------------ ---- ----------------- -- - --------------------------------------------- ---- ---- - -- - -- -- -- -- -- -- ------ ------- ---- ----- CONTACT PSE BEFORE .............. ......... --------------------------------------- --------------------------------------------------------- .. -- - -- - --- --- - ----- -- ------ - - - - -- ---- -------- - - ................................................ ............... .............. -- .. ?OTFi01JNG _ 8" GAS ® EX SDMH ASBLT; a a BACKFILL MATERIAL - - - UNK EL RIM EL =1 36 = RIM 130.34 - - = as NATIVE IF IT: MEETS SPECS, OR IMPORT. PER = NE S 12" 155 tU9.94 :SE^" 03 (BA K :RU EL). EX SDMH ASBLT ON 9- .19 N N GRAVEL). - W 15.38 is W 78 ".IE.114.- RIM EL- 10 -67 RIM 110.68 - a _ "SS: 12 rJ:' - NE 20" IE .0 NE 90.78 C 6 APPROX LOG SW 21" IE =: 8 0 S 90.78 _ _ B -1, TYPE 1L = CONFIRM ABANDONED FRAME AND: GRATE ASBLT a E s" IE =i 06.4 E 105.43 RIM EL= 4.77 RIM .114.51 _ _ a PIPE ZONE MATERIAL E 18° IE 1 00 E 110.43 REMOVE N 6" _ RI l S M - EL 8 NEW E 18" _IE =10 2 - : W 18" IE -310. W : 110.61 _ - - O PER 6 .1 n - WSJ 8 EDD ......... ........ ..._.720 - --- _...:. - --I- ....... .... ..- 12 ._ .. .. -... ... .. .------- 12 MIN. AVEL 6 L ZO B ING ------ ......._. - -- --_- _ ---- :- ------... -------RIM 1118.83 {} GR ACttFIL FORnPIPE NE "" REMOVE EX CB CL CHAN104.74: is AND 6" PIPE \ NEW UTILITY' PIPE _.... _ -. -. , _... - - i - 1 - - -- -- - - -- .. _..... 6 °MIN 115 _ a EXCAVATION'OF UNSUITABLE SOIL (IF NEEDED) a DEPTH AS APPROVED � 3 BACKFILL WITH FOUNDATION MATERIAL. M a I MEETING 9 13 UARRY SPA O LLS O -- - - -- - - - .6 - NOTES ............. ..... ------- - .. 8:55..... i ..... ... .'2..... (... _. ..: --------------------------------------- 110 _ .. - -..110 EST EL : _ - -- 1. PROVIDE UNIFORM SUPPORT UNDER BARREL. EsT: 2. HAND TAMP UNDER HAUNCHES. ? GAS 3. COMPACT PIPE ZONE MATERIAL TO 90 MINIMUM DENSITY EXCEPT DIRECTLY OVER PIPE WHERE COMPACTION WILL BE HAND TAMP ONLY. 4. PIPE MUST BE ANCHORED :IN SUCH A MANNER AS TO 3 O.. .. ...._....... (1.. ... ENSURE.. FLOW -.. MAIN . NED ..... :.105 - ... ................................... -- ... ...:................... :............................ .............................:. ------ - - - -- ........... ............... ............... ............... ..- --- --...---- --- ---- ---- - ---- --- -- ---...--- - -- ------- - -. - -- LINE IS TAI .. -------....--- -----...... -. .......................................... 5� LF 18 "CPEP ® -0'8648. FT /FT 54 LF A 0.0917 _ REMOVE EX 6 "SD ®� � LF 18 "CPEP ®� h93H FT /FT AS -BUILT SURVEY BY. I .......... ..._........ ... -- - --- ............ ....... - ............... 43. ...:.. ®0.120... ...... _... - _ - _ 100 11800 nB W NE fi th St 98091 -4156 I� 6 `A PHONE: 425 - 488 -4800 FAX 425- 483 -2315 ✓ Douglas �D(CPlooms es PILS PLS 974 12/19/07 /-%S-BUILT' ............ ................... ............. ----------------------------------------------------------- ................................................................................ ................... --------------------------------------- ................... ................ . .......... .............. ................................................................ .......... ........................ .............................. -------------------------------------------------- ................... ................... .............................................. CHECKED FOR COMPLIANCE of WASyi 1 ADDENDUM 1 -ADDED SIDEWALK RAMP STOP B R AReF4 9aV,m 8/23 2006 TO CITY STANDARDS RECOMMENDED ORIGINAL PLAN STAMPED GULLY RESTORATION DWC' 8/23 6 BAs Noted ��. ,� / ORIGINAL PLAN SIGNED BY: AND SIGNED 8/18/06 i GLF, DWC CITY OF RENTON AVE S / S 3rd ST FOR APPROVAL ADD ASBUILT ELEVATIONS REVISIONS PER SURVEY DWC 7 25 07 RONALD STRAKA 8/18/06pa }e BY: RONALD J. ST72AKA ° GLF. DWC RENTON STORM SYSTEM OUTFALL RELOCATION P� PE# 29727 LYS HORNSBY 8 /i8 /OC�ate BY DANIEL CAREY 8/186 MIKE STENHOUSE DATUM EXPIRES 10/16/07 Cl °R JS ar n� Planning /Building /Public Works Dept. Date BY NO. REVISION BY DATE APPR Rds - 1 -2 P3: x.3 4 ,ors emea D- 333401 ROLL 2U 1FR 13;5', to Y61 y Vl z z a °y N �0 -NC ' rHn w r r