Loading...
HomeMy WebLinkAboutD-342638N 12" DIA CPEP SD - - IE 20.00' \ CONNECT EXISTING 12" CONC SD (W) 11 I.E. ±22.92' �_ CB #36 i j CB TYPE 1 12" CPEP SO IE = 22.92' 12" DIA CPEP SD — IE 19.28' i CB #3A 48" DIA CB TYPE 2 CONNECT EXISTING 12" CONC SO (W) I.E. ±20.07 I- � I �� J � II I L__J i� -/ - I CB2188 CATCH BASIN (REMOVE) ROSEWATER CLIENTS I PEOPLEI PERFORMANCE 1a01 TN1a0 AVENUE, SUITE 1500 6 SEA rnE. e+ASluNCruN 98101 - 3033 DMJM HARRIS I AECOM 10900 NE 8TH STREET, SUITE 750 BELLEVUE, WASHINGTON 98004 PHONE: (425) 454 -5600 FAX: (425) 454 -0220 12" CPEP SD IE = 20.07' i 1 - APPROX LOCATION ABANDONED SEWER MH PER RENTON AS -BUILT W -954 LJ 12" CPEP SD 48" CPEP SD j I I #5 ___ IE = 21.39' IE X116.28' 72" DIA CB I TYPE 2 I I CBS #31 18" DIA QI SD 1 84' DIiA CB TYPE 2 IE 18.28' I 1 / 1 I i i e I I _L MH2182 \ iI -h SANITARY SEWER t� ^fir - - - - 1_2'' SS - - ---- - -J -+- 18" PVC SS CROSSING, I I r _ - A (BELOW 18" DI SD) 1 3: 1 I I I�I j N j 18" DI SD IE = 18.22' PROVIDE 30" KNOCKOUT 4�" CEP SD FOR FUTURE. IE I= 16.28' CORE DRILL FOR 18" I I CONNECTION � � J APPROVED FOR CONSTRUCTION m DATE CB #3 & CB #5 DETAIL SCALE: 1"=4' Sk I I \ - ------ - - - - -- - 16" C.I. W CROSSING, (ABOVE 18" DI SD) zl� I_ ADDENDUM NO. 1 WRE 107/091 KRS NO. I REVISION i BY DATE I APPR 12" CPEP SO IE = 21.39' 18" CPEP SO ZA IE = 18.22' _1_2"_C iP SD IE = 21.39' 12" CPEP SD IE = 19.63' A SCALE ACCORDINGLY VARIES K SMITH R. EDRALIN NOTES: 1. METAL PARTS: CORROSION RESISTANT. NON- GALVANIZED PARTS PREFERRED. GALVANIZED PIPE PARTS TO HAVE ASPHALT TREATMENT 1. 2. FRAME AND LADDER OR STEPS OFFSET SO: A. CLEANOUT GATE IS VISIBLE FROM TOP. B. CLIMB -DOWN SPACE IS CLEAR OF RISER AND CLEANOUT GATE. 3. IF METAL OUTLET PIPE CONNECTS TO CEMENT CONCRETE PIPE: OUTLET PIPE TO HAVE SMOOTH O.D. EQUAL TO CONCRETE I.D. LESS � ". 4. PROVIDE AT LEAST ONE 3 "x0.090 GAGE SUPPORT BRACKET ANCHORED TO CONCRETE WALL. (MAXIMUM S -0" VERTICAL SPACING) PIPE SUPPORT -� �.� 18" SHEAR GATE SEE RENTON STD PLAN 18" OVERFLOW RISER -� B033 IE =22.46 CONNECT TO EXIST 18" SD TO WEST - - - - - -� IE= 20._21 \ EXIST 12" FROM NORTH IE =17.65 L _ 48" TO SOUTH IE =16.81 84" CB TYPE 2 CLEANOUT PLATE WITH GASKET BOLTED TO FLANGE ON RISER BASE CB #10 DETAIL 0 SCALE: 1 " =4' D- 342638 RAINIER AVE S (SR 167) :ORNTAL HAD 1983 /1991 IMPROVEMENTS PROJECT :4 CITY OF PHASE 1 RENTON SHATTUCK AVE S STORMWATER BYPASS DATUM Public Woks Dept. STORM DRAINAGE & UTILITIES FED AID NO.: ARRA - 0167(044) DETAILS 11 IOI- 1217131412 ON� M DE LILLA AT FT ONE IF NOT ONE INCH SCALE ACCORDINGLY D. K. SMITH NOTES: 1. METAL PARTS: CORROSION RESISTANT. NON- GALVANIZED PARTS PREFERRED. GALVANIZED PIPE PARTS TO HAVE ASPHALT TREATMENT 1. 2. FRAME AND LADDER OR STEPS OFFSET SO: A. CLEANOUT GATE IS VISIBLE FROM TOP. B. CLIMB -DOWN SPACE IS CLEAR OF RISER AND CLEANOUT GATE. 3. IF METAL OUTLET PIPE CONNECTS TO CEMENT CONCRETE PIPE: OUTLET PIPE TO HAVE SMOOTH O.D. EQUAL TO CONCRETE I.D. LESS � ". 4. PROVIDE AT LEAST ONE 3 "x0.090 GAGE SUPPORT BRACKET ANCHORED TO CONCRETE WALL. (MAXIMUM S -0" VERTICAL SPACING) PIPE SUPPORT -� �.� 18" SHEAR GATE SEE RENTON STD PLAN 18" OVERFLOW RISER -� B033 IE =22.46 CONNECT TO EXIST 18" SD TO WEST - - - - - -� IE= 20._21 \ EXIST 12" FROM NORTH IE =17.65 L _ 48" TO SOUTH IE =16.81 84" CB TYPE 2 CLEANOUT PLATE WITH GASKET BOLTED TO FLANGE ON RISER BASE CB #10 DETAIL 0 SCALE: 1 " =4' D- 342638 RAINIER AVE S (SR 167) :ORNTAL HAD 1983 /1991 IMPROVEMENTS PROJECT :4 CITY OF PHASE 1 RENTON SHATTUCK AVE S STORMWATER BYPASS DATUM Public Woks Dept. STORM DRAINAGE & UTILITIES FED AID NO.: ARRA - 0167(044) DETAILS 11 IOI- 1217131412