AC ASBESTOS CEMENT PIPE
ADJ ADJUST
ALT ALTERNATE
ALUM ALUMINUM
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE
AP ANGLE POINT
ASPH ASPHALT
ASTM AMERICAN SOCIETY OF TESTING AND MATERIALS
ASSY ASSEMBLY
BF BLIND FLANGE
BLDG BUILDING
BLK BLOCK
BO BLOW OFF
BOP BEGINNING OF PAVEMENT
CTR CENTER
CAP CORRUGATED ALUMINUM PIPE
CB CATCH BASIN
Cl CAST IRON
CL CENTER LINE
CLR CLEARANCE
CMP CORRUGATED METAL PIPE
CO CLEANOUT
CONIC CONCRETE
CONN CONNECTION
CONTR CONTRACTOR
CONT CONTINUOUS
CPEP CORRUGATED POLYETHYLENE PIPE
CPLG COUPLING
CY CUBIC YARD
CONT CONTINUED
CL CLASS
CF CUBIC FEET
U0011211110v 011161m
RED
REDUCER
REINF
REINFORCE
READ
REQUIRED
R/W
RIGHT -OF -WAY
SL
SLOPE
24 N, R 5 E, W.M.
SYMBOL
SCH
SCHEDULE
SF
SQUARE FEET
SFM
FOUND MONUMENT
SHT
SHEET
SPECS
SPECIFICATIONS
SQ
SQUARE
SSCO
SANITARY SEWER CLEANOUT
SSMH
SANITARY SEWER MANHOLE
SSNT
SET NAIL /TAG
SSRC
SET REBAR /CAP
STA
STATION
STD
STANDARD
TB
THRUST BLOCK
TC
TOP OF CURB
TEL
TELEPHONE
THIRD
THREADED
THRU
THROUGH
TYP
TYPICAL
VERT
VERTICAL
SANITARY SEWER
W/
WITH
W/0
WITHOUT
WTR
WATER
CFS CUBIC FEET PER SECOND SYMBOL LEGEND
DC DEGREE OF CURVATURE
DI DUCTILE IRON EXISTING PROPOSED DESCRIPTION
DIA DIAMETER
DOT DEPARTMENT OF TRANSPORTATION
DIM DIMENSION -- - -" -"
DWGS DRAWING(S) _
D DRAIN
EOA EDGE OF ASPHALT
E EAST - ::.,.._....,._:.. -.,_.
EA EACH
EL ELEVATION
ELEC ELECTRICAL
EOP EDGE OF PAVEMENT
EXIST EXISTING
F FORCE MAIN s =]__ .._(
FIG FIGURE
FIN FINISHED
FL FLANGE
FT FEET
FO FIBER OPTIC
FOC FACE OF CURB
GA GAUGE
GALV GALVANIZED
GI GALVANIZED IRON
GV GATE VALVE
HDPE HIGH DENSITY POLYETHYLENE PIPE
ID INSIDE DIAMETER -
IE INVERT ELEVATION
INV INVERT _
IN INCH
L LENGTH -
LB POUND
LF LINEAR FEET
MAX MAXIMUM
MFR MANUFACTURER -
MH MANHOLE
MIN MINIMUM
MJ MECHANICAL JOINT
MISC MISCELLANEOUS
N NORTH
NO NUMBER
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
PI POINT OF INTERSECTION -
PP POWER POLE
PVI POINT OF VERTICAL INTERSECTION -
PE PLAIN END
PERF PERFORATED
PVC POLYVINYL CHLORIDE
PVMT PAVEMENT
PVT POINT OF VERTICAL TANGENT _
PC POINT OF CURVATURE
QTY QUANTITY TANGENCY
R RADIUS
REf RETAINING
RR RAILROAD
ANN
oF�X ti
�ar
38311
c
Cn,ay 8E 08b0r2X0, Imo.
CONSULTING ENGINEERS
701 DEXTER AVENUE NORTH SUITE 200
SEATTLE, WASHINGTON 98109 (206) 284 -0860
-- G -- - -{
DO
\ i
0
SECTION
32, TWP
24 N, R 5 E, W.M.
SYMBOL
LEGEND
EXISTING
PROPOSED
DESCRIPTION
0
LINE
MANHOLE OR DRYWELL (AS NOTED)
o
CLEANOUT
L
®
TYPE 1 CATCH BASIN OR CURB INLET
BURIED CABLE TV
®
TYPE 2 CATCH BASIN
BURIED FIBER OPTIC
POLE WITH GUY WIRE
_
-v-
POWER / TELEPHONE / GUY POLE
WATER MAIN (SIZE AS
NOTED)
LUMINAIRE
GAS MAIN
YARD LIGHT
:1
JUNCTION BOX (AS NOTED)
D4
N
GATE VALVE
SANITARY SEWER
BUTTERFLY VALVE
s
WATER METER
Y`
fi
FIRE HYDRANT
REDUCER
®
THRUST BLOCK
TRANSITION COUPLING OR
FLANGE COUPLING ADAPTER
CURB & GUTTER
CAP /PLUG
ASPHALT PAVEMENT i BLOW -OFF
GRAVEL SURFACING AIR RELEASE VALVE
CONCRETE SURFACING
CONCRETE SIDEWALK (PERVIOUS CONCRETE/ - --
CEMENT CONCRETE)
PAVEMENT GRINDING LIMITS
Y
RIGHT -OF -WAY LINE —
CENTERLINE OF ROADWAY
PROPERTY LINE
NOTED
PERMANENT EASEMENT
LINE
TEMPORARY EASEMENT
LINE
NOTED
CONTOUR LINE
BURIED CABLE TV
N
BURIED FIBER OPTIC
BURIED POWER
BURIED TELEPHONE
u1
WATER MAIN (SIZE AS
NOTED)
GAS MAIN
IRRIGATION LINE
>a
SANITARY SEWER
STORM DRAIN
SANITARY SEWER FORCE MAIN
DITCH
CULVERT (SIZE & TYPE AS NOTED)
FENCE (TYPE AS NOTED)
FENCE (WITH GATE)
TELEPHONE VAULT
POWER VAULT
TELEPHONE MANHOLE
WAHLSTROM, PLS#44651
(INFORMED LAND SURVEY)
THE ORIGINAL PLANS WERE STAMPED
BY SC AND BB ON 2/14/2011 & 2/1512011 N0.
ok
�l
-d ?t-
MAIL BOX (NOTED)
SIGN
EMBANKMENT
TREE (CONIFER)
iv
0 TREE (DECIDUOUS)
C�? SHRUBS
BUILDINGS
ROCK WALL
DCDO= BLOCK WALL
ELEVATION POINT
MONUMENT
ANGLE POINT / CONTROL POINT
BENCH MARK
1 DETAIL NUMBER
1
REFERENCE SHEET
GEOTECHNICAL BOREHOLE
TOE OF FILL
F— EMBANKMENT
GRADING QUANITIES
CUT: �2,38t�CjiS�(�Y
FILL: 3ArjI1(Cy 450v
GENERAL CONSTRUCTION NOTES
1. ALL TYPE 2 CATCH BASINS AND ACCESS RISERS SHALL HAVE FLAT TOPS
2. LENGTHS OF PIPE AND INVERT ELEVATIONS ARE SHOWN AT CENTERLINE OF
STRUCTURE.
3. CONSTRUCTION WORK HOURS SHALL BE FROM 7:00 AM TO 5:00 PM, MONDAY
THROUGH FRIDAY UNLESS NOTED OTHERWISE IN THE SPECIFICATIONS.
CONTRACTOR SHALL ABIDE BY THE CITY OF RENTON NOISE ORDINANCE.
4. LOCATE ALL CATCH BASIN AND MANHOLE FRAMES AND GRATES OUTSIDE OF
VEHICLE WHEEL PATH WHERE FEASIBLE (WHERE NOT FEASIBLE, INSTALL ROUND
COVERS).
5. ALL TYPE 1 AND 2 CATCH BASINS SHALL HAVE VANED GRATES EXCEPT WHERE
NOTED ON THE PLANS.
6. CONTRACTOR SHALL SUBMIT A TRAFFIC CONTROL PLAN FOR OWNER'S APPROVAL.
UTILITY NOTE:
THE CONTRACTOR SHALL CALL THE UTILITY LOCATION REQUEST CENTER
(ONE CALL CENTER; 1 -800- 424 -5555) FOR FIELD LOCATION OF UTILITIES.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION,
DIMENSION, AND DEPTH OF ALL EXISTING UTILITIES WITHIN THE PROJECT,
WHETHER SHOWN ON THESE PLANS OR NOT, BY POTHOLING THE UTILITIES
AND SURVEYING THE VERTICAL AND HORIZONTAL LOCATION PRIOR TO
CONSTRUCTION. ALL POTENTIAL UTILITY CONFLICTS SHALL BE POTHOLED A
MINIMUM OF FIVE WORKING DAYS IN ADVANCE OF ANY PIPELINE TRENCH
EXCAVATION. THE UTILITIES SHOWN ON THE PLANS ARE BASED UPON
AVAILABLE INFORMATION AND ARE SUBJECT TO VARIATION. IF CONFLICTS
OCCUR THE CONTRACTOR SHALL CONSULT THE PROJECT ENGINEER TO
RESOLVE THE PROBLEM PRIOR TO PROCEEDING WITH CONSTRUCTION.