Loading...
HomeMy WebLinkAboutD-353108T M Lfi M I` N D_ -P & LANN 'aF Fdgy'QG G� OF Wdgg �3 ro �"H 37338 ..9 �v' �o. A„ 38311 „ C=ray 8C 0ab0ra1I,4_-9 lxkrc CONSULTING ENGINEERS 70' DEXTER AVENUE NORTH SUITE 200 SEATTLE, WASHINGTON DOM (206) 284 -0860 SECTION 32, TWP 24 N, R 5 E, W.M. 24" 0 ACCESS HATCH BAFFLE WALL - TOP EL. =28.62 24" SHEAR GATE W /CONTROL ROD 1" (POLY) SAFETY TYPE :. - == - - -7% _ `: LF, 2682 MANHOLE LOCATED STEPS __.�,' ✓ AT 12" O.C. '� 24 CPEP MULLEN BURST STRENGTH (ASTM D3786 -800) 400 PSI MIN. ADS (ASTM D4751) 20 -45 (U.S. STANDARD SIEVE SIZE) IE . 16.39 ` OUTLET PIPE 12" CPEP TO BIOSWALE I e = 17.49 ' - y ',.....: � 72 "0 PRECAST MH 24" CPEP - ----- -- LE. =26.62 - BYPASS PIPE ° _ i_ -77 - -- — "'c- 24 CPEP - —i 1" (POLY) SAFETY TYPE ROD FOR CLEANOUT I e. = 26.49 MANHOLE STEPS LOCATED AT 12" O.C. FLOW RESTRICTOR /SEPARATOR P ` 1 1 RIM EL. 33.05 FLOW RESTRICTOR / SEPERATOR v. PIPE SUPPORT(S): SEE NOTE 3 `INLET PIPE 200 PSI MIN. '� 24 CPEP MULLEN BURST STRENGTH (ASTM D3786 -800) 400 PSI MIN. ADS (ASTM D4751) 20 -45 (U.S. STANDARD SIEVE SIZE) IE . 16.39 ` OUTLET PIPE 12" CPEP TO BIOSWALE I e = 17.49 D' CB2 FLOW SPUTTER 1 NOT TO SCALE 5 L-6° MIN. GRADE TO DRAIN (TYP.) SEPERA71ON GEOTEXTILE TO BE PLACED UNDER ROCK (SEE NOTE 1). MINUS ROCK 1>b1tEB 1. GEOTEXTILE SHALL MEET THE FOLLONING STANDARDS: GRAB TENSILE STRENGTH (ASTM D4751) 200 PSI MIN. '� 24" 0 ACCESS MULLEN BURST STRENGTH (ASTM D3786 -800) 400 PSI MIN. ADS (ASTM D4751) 20 -45 (U.S. STANDARD SIEVE SIZE) HATCH 6 ' - y ',.....: � 72 "0 PRECAST MH 24" CPEP - ----- -- LE. =26.62 - SHEAR GATE W /CONTROL 1" (POLY) SAFETY TYPE ROD FOR CLEANOUT ' MANHOLE STEPS LOCATED AT 12" O.C. FLOW RESTRICTOR /SEPARATOR Q4Qgs�P GAO .N •n• 00,`ryo� a 11 n-4 Nlm'g WELDED RESTRICTOR PLATE WITH 3" DIA. ORIFICE AT EL =25.79 CB2 FLOW SPUTTER 1 NOT TO SCALE 5 L-6° MIN. GRADE TO DRAIN (TYP.) SEPERA71ON GEOTEXTILE TO BE PLACED UNDER ROCK (SEE NOTE 1). MINUS ROCK 1>b1tEB 1. GEOTEXTILE SHALL MEET THE FOLLONING STANDARDS: GRAB TENSILE STRENGTH (ASTM D4751) 200 PSI MIN. GRAB TENSILE STRENGTH (ASTM D4632) 30% MAX. MULLEN BURST STRENGTH (ASTM D3786 -800) 400 PSI MIN. ADS (ASTM D4751) 20 -45 (U.S. STANDARD SIEVE SIZE) WAHLSTROM, PLS #44651 (INFORMED LAND SURVEY) THE ORIGINAL PLANS WERE STAMPED BY SC AND BB ON 2114/2011 & 2/1512011 GRAVEL ACCESS PAD 2 NOT TO SCALE 5 ''Lim • E 70.VM WATIO IEimim, 2 - 24 "O ACCESS HATCH D. . I.E. =30.00 o-T 0 T2' -0" MIN 1' -0" 2' -0" MIN SECTION A NOT TO SCALE _ 72 "0 PRECAST MH SHEAR GATE W /CONTROL ROD FOR CLEANOUT BAFFLE WALL TOP EL. 28.62 24" SHEAR GATE W /CONTROL ROD I.E.= 26.62 24" CPEP 69._26.622 .. IE� 74.39 D EL. =22.62 NOTES: 1. THE RESTRICTOR /SEPARATOR SHALL BE FABRICATED FROM .60" ALUMINUM OR .064" .ALUMINIZED STEEL OR .064" GALVANIZED STEEL PIPE IN ACCORDANCE WITH AASHTO M 36, M196 AND M274. GALVANIZED STEEL SHALL HAVE ASPHALT TREATMENT 1. 2. OUTLET SHALL BE CONNECTED TO STORM DRAIN PIPE WITH A COUPLING BAND. 3. PROVIDE AT LEAST DINE 3 "x0.090" SUPPORT BRACKET ANCHORED TO CONCRETE WALL. (MAXIMUM 3' -0" VERTICAL SPACING.) 4. FRAME AND LADDER CDR STEPS SHALL BE OFFSET SO THAT (1) CLEANOUT GATE IS VISIBLE FROM TOP. (2) CLIMB -DOWN SPACE IS CLEAR OF RISER AND CLEANOUT GATE. (3) FRAME IS CLEAR OF CURB. 5. CLEANOUT GATE /SHEAR GATE: ALUMINUM ALLOY PER ASTM B26 -ZG32A OR CAST IRON ASTM A48 CLASS 30B AS REQUIRED. LIFT HANDLE EITHER SOLID OR TUBING WITH ADJUSTABLE HOOK AS REQUIRED. NEOPRENE RUBBER GASKETS REQUIRED BETWEEN FLANGES. 6. METAL PARTS: CORROSION RESISTANT ALUMINUM. IF STEEL SUBSTITUTED FOR ALUMINMUM, GALVANIZED PARTS NEED TO HAVE ASPHALT TREATMENT 1. 7. BAFFLE WALL SHALL BE FABRICATED TO WITHSTAND 2 FEET OF HYDRO STATIC PRESSURE. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR REVIEW. SUR.tl}R 9'.11P r�:NpDIOT CITY OF oWt B.P.B. .� RENTON C.J.K. ' arc nom DATUM °� AT�6.,E I Public Works Dept. SA.C. T.O UE pg aa<x Apq�p� VE �Y B.P.B. AS -BUILT -353 1 0, OpE LAKE WASHINGTON BLVD NORTH 2/14/11 STORM WATER & WATER MAIN IMPROVEMENTS STORM NOTES AND DETAILS 8 OR 27 I