Loading...
HomeMy WebLinkAboutS-301003N88 °49'09,*p w 09 "W ,TAN 76.89 LOT A L AKE WVASHING TON WA TER EL EVA TION 21.85 = O.H.W.L. —CORPS OF ENGINEERS NGVD 1983 18.50 = 0. N. W.L. — CITY OF REN TON LOT B 438.37' LOT C 475.92' PORTION OF GOVT LOT 2 OF SECTION 32, TOWNSHIP 24 NORTH, RANGE 5 EAST, W.M. CITY OF RENTON. S TA.TF OF WA Sr- riniGrnni � o �� 0000, Ar 0.040" 01 ko, �-�O 00000' 00000' �P I 0� I / P 0 �' ''0 _ G / PROPOSED 1 13 / -- G - � ' / �' le ,' FROM BAR p 000010 _A� I —' �^� 0� P y, dI rU rIC ►r (IIAVUUI / J AIL THIS SHEET , jO :X. SEWER LOCKING '.J. (VERTICAL) A\O 12 ` �X� rx J V` P 4 (V .3 -PHASE POKFR TO LIFT STA. 17=20 ' )ZRAPHIC SCALE 10 20 40 ( IN EMT I inch = 20 it. INSTALL 8" THICK CONCRETE PAD OVER POWER AND SEWER CONDUITS WHERE COVER UNDER NEW ROADWAY WILL BE LESS THAN 3'. ' r �• 'i EX. 6" FORCE MAIN FOR SEWER •% W/3 PHASE POWER TO BE RELOCA TED AND REMOVED FROM THIS TRENCH DEADMAN SEE SH T. 9 T51 N DETAILS rr% IIL •� EXIS71NG <!7 LIFT STA 710N CONNECT TO EX. SEWER MAIN. 1- DEADMAN BLOCKING NO TE• 1 -30• BEND -R.J. EXISTING 6" FORCE MAIN IN LOT "D" MA Y NOT BE REMO VED OR FOUNDA PONS EXCA VA TED UN TIL THE SEWER FORCE MAIN HAS BEEN RELOCA TED. SEWER FORCE MAIN TO BE RELOCA TED USING 6" DI CLASS 52. JOINTS SHALL BE RESTRAINED USING UNIFLANGE UNIFLANGE SERIES 1300 ON DI PIPE. ALL FITTINGS SHALL BE STANDARD DUCTILE IRON FITTINGS. COORDINA TF POWER RELOCA 7101V WI TH PUGET SOUND POWER. ROLL 2 0,� LUA-96-153LLA LND— 30— 0159 469.38 (MEA S, S 88 °49'09" E 40th S TRI FOUND COPPER TACK IN CONCRETE ROAD W STEEL RING AS CASE BLVD & N 40TH ST INTERSECTION (10/21/93) SEMER FORCE MAIN REL OCA TION REOUIREMEN TS: I. CON TRACTOR, TO VERIFY L OCA TION OF EXIS TING FORCE MAIN AT LIFT STA 17ON AND AT RAILROAD RIGHT OF WAY CROSSING. 2. ALL SEWER AND FORCE MAIN REL OCA TION WOR-in SHALL BE COORDINA TED WI TH THE Cl T Y OF REN TON PERSONNEL. J. INSTALL GRA W TY SEWER AND OTHER U77LI TIES AS NEEDED ADJACENT TO THE PROPOSED FORCE MAIN. 4. INSTALL AND TEST NEW FORCE MAIN. 5. MAKE FINAL CONNECTIONS TO THE EXISTING FORCE MAIN PER DETAIL AND CITY REQUIREMENTS. 6. RELOCA TE POWER TO THE SEWER LIFT STA TION B Y PUGS T SOUND ENERG Y. COORDINA TE WI TH CITY OF REN TON PERSONNEL. 7 REMOVE EXISTING SEWER FORCE MAIN. 8 REMOVE EXISTING OLD ELECRICAL CONDUITS BY PUGET SOUND ENERGY. 9. CON TINUE CONS TRUC TION WI TH THE REMAINDER OF THE U TILT TIES, AND STREET IMPRO IIEMEN TS DEADMAN SEE SHT. 9 FOR DETAILS CONNECT TO EX. SEWER FORCE MAIN. 1- DEADMAN BLOCKING 2 -45• BEND -R. J. VERTICAL) 1--6" NIPPLE AS REQ V. t� INSTALL NEW 6 "SEWER FORCE MAIN. 100 LFf ALL FORCE MAIN CONSTRUCTION KILL REQUIRE REV RAINED JOINTS AS REQUIRED IN NOTE BELOW 2 -30' BENDS -R. J. 1 -6" NIPPLE AS REQ'D. CONNEC TION DETAIL SEE SHEET 8 OF 12 FOR PROFILES �F I;t 20,,3— ah "AS— BUILT" NOTE: I EXPUMS 'AS-- BUILT" IS BASED ON A ACTUAL FIELD SURVEY BY TOUMA ENGINEERS AND INFORMATION SUPPLIED BY CONTRACTOR. RECOMMENDED FOR APPROVAL BY DATE BY DATE BY DATE BY DATE BY DATE �3 � 3cica 21 r 0 W N Cr O Ls- `v r a F- 3 0 Z o V U W � W a W W � cr Tr T to h a W A� ft a Wa W 4 Z 1►� �N 4 a Tal o■ Z Q U a a) W 0 or W J -- 2 Z C� t rA C11 N 'r N 4 n n a� z ° a N � J to a y N � Z Q U a a) W 0 or W J -- 2 Z C� t rA C11 N 'r N 4 n n a� z ° a N � J to a y