Loading...
HomeMy WebLinkAboutS-302003Ln M Z z 0 2 cr Ln W O 'z W 6" MIN. 0° MIN. t 1/2 BLIND FLANGE AS DAM D.I.P. TEE CL-50— ONE LENGTH OF DUCTILE IRON PIPE (CLASS 50) TO SOLID BEARING WHEN SPAN IS MORE THAN 4'. L FLEXIBLE JOINT BACKFILL WITH COMPACTED MATERIAL AS DIRECTED BY ENGINEER. D.I.P. CI.50 6° MIN. WITH MIN. 4 SHACKLE RODS CEMENT CONCRETE CLASS C BLOCK POURED IN PLACE —� D.I.P. 90' BEND / CL50(MJ X PE) DUCTILE IRON DROP CONNECTION �i 1/2 PLUG AS DAM T' -t'T TYPICAL TEE / MANHOLE � Al ' c - ; �A '1 < CHANGED DWG NAME FROM 8WIS TO OR188 I Q 10/17/96 � I• 6" MIN. IN o DCV AG AN � 6" MIN. _F 6" MIN. :J , I I rr - - -.: 2" MIN. r 6" MIN. CHANGED DWG NAME FROM 8WIS TO OR188 DCV DT 10/17/96 ,rtis DCV 6" MIN. 3/6/95 CORRECTED TEXT DCV AG 112/15/921 CORRECTED TEXT RTM DT DATE I IL .. BY APP R � TYPICAL MANHOLE —� FOUNDATION CONSTRUCTION � 6" MIN. _F 6" MIN. :J , I I rr - - -.: 2" MIN. r 6" MIN. ONE LENGTH OF DUCTILE IRON PIPE (CLASS 50) TO SOLID BEARING WHEN SPAN IS MORE THAN 4'. FLEXIBLE JOINT BACKFILL WITH COMPACTED MATERIAL AS DIRECTED BY ENGINEER. CEMENT CONCRETE CLASS C POURED IN PLACE ' ;� - 90' BEND - = (TYTON U-651) CONCRETE ENCASED DROP CONNECTION 8/97 CHANGED DWG NAME FROM 8WIS TO OR188 DCV DT 10/17/96 EDITED TEXT DCV 6" MIN. 3/6/95 CORRECTED TEXT DCV AG 112/15/921 CORRECTED TEXT RTM DT DATE I IL .. BY APP R � � TWO -WAY CLEANOUT PRECAST 1 ONE LENGTH OF DUCTILE IRON PIPE (CLASS 50) TO SOLID BEARING WHEN SPAN IS MORE THAN 4'. FLEXIBLE JOINT BACKFILL WITH COMPACTED MATERIAL AS DIRECTED BY ENGINEER. CEMENT CONCRETE CLASS C POURED IN PLACE ' ;� - 90' BEND - = (TYTON U-651) CONCRETE ENCASED DROP CONNECTION 8/97 CHANGED DWG NAME FROM 8WIS TO OR188 DCV DT 10/17/96 EDITED TEXT DCV AG 3/6/95 CORRECTED TEXT DCV AG 112/15/921 CORRECTED TEXT RTM DT DATE I REVISION BY APP R DROP SANITARY SEWER MANHOLE DETAIL NTS �13CtS5T'� `���, ,o�o��R�C1 1144 Eastlake Ave. E. T (206) 522 -9510 SS/oNnt, � SS/oxAL' Suite 601 F (206) 522 -8344 WWIW Seattle, WA 98109 www.PAcLAND.com EV= JULY 7. CHO MUST 5, 2= h► wP . _�.�►� 0 SOP G1111111111nmunumFOR 3ANIT�RY Y ADOPTED CITY OF RENTON Standard plans I3f DATE: W" DWG. NAME: 88188 SP PAGE: 8075 CHECKED FOR COMPLIANCE RECOMMENDED TO CITY STANDARDS FOR APPROVAL DATE BY DATE BY DATE BY 'ifyl DATE C/i..,'t I BY CONCRETE ADJUSTMENT RINGS TO SUIT DEPTH OF INTERCEPTOR INLET -� REINFORCED PRECAST CONCRETE FTWO 240 DIAMETER cAsr NtON MANHOLE RINGS IMTH HEAVY DUTY GAS -MT COVERS - SLOPE PAVEMENT OR GRADE AWAY FROM MANHOLES 4' CLEANOUT, TOP SIMILAR TO YCO TYP OF 2 24'x24'x8' CONCRETE PAD TYP OF 2 OPENING TWO -WAY CLEANOUT TYP OF 2 SEAL WATERTIGHT SECTION A TYP OUTLET AT 1/3 LIQUID DEPTH FROM BOTTOM, MINIMUM OF 24" NOTES: BED OF UNDISTURBED 1 • PROVIDE SAMPLING EARTH OR COMPACTED PORT DOWNSTREAM DETAIL SHOWS GENERAL 'SCHEMATIC REQUIREMENTS. CONTRACTOR SHALL SUBMIT SAND BACKFILL 4 " -6" OF CONJUNCTURE WITH PROPOSED INTERCEPTOR INSTALLATION PLANS AND SPECIFICATIONS TO AUTHORITIES MAIN SANITARY SEWER. HAVING JURISDICTION FOR APPROVAL BEFORE ACQUISITION OF INTERCEPTOR. 2. REFER TO PLUMBING PROVIDE INTERCEPTOR WITH ADEQUATE STRUCTURAL STRENGTH TO ACCOMMODATE � �30? 0 �3 PLAN FOR PIPE SIZES. VEHICULAR TRAFFIC AT INSTALLATION LOCATION. NOTE: THIS DETAIL IS SHOWN FOR REFERENCE ONLY. SLL ARCHITECTURAL /MECHANICAL PLANS. PRECAST OIL INTERCEPTOR BAFFLE MP07 11.30.01 CONCRETE ADJUSTMENT RINGS TO SUIT DEPTH OF INTERCEPTOR OPEN ON TOP TYP 1 1 NTS THREE 24" DIAMETER CAST IRON MANHOLE RINGS WITH HEAVY DUTY GAS -TIGHT COVERS — SLOPE PAVEMENT OR GRADE AWAY FROM MANHOLES VENT �Q BAFFLE r�l REF PLAN - .0 Z 4" CLEANOUT, TOP SIMILAR TO YCO TYP OF 2 24 "x24 "x8" CONCRETE PAD TYP OF 2 MP07B 11.30.01 " ARGM MSEN C.E. : NONE JRG 3 FINAL PERMIT COMMENTS RESIMITTAL M AND 5 703 �w": JKH 2 PERMIT COMMEWTS RESUBMITTAL PACLAND 4 18 03 CHECKM�.� AT --� FULL F P NOT ONE INCH N0. REVISION BY DATE APPR JRG WALE A�0R01Na'' I. i VERTICAL: NAVO IM. NJ 2123 ELEVATION 45.11 FEET HOR1zowm- P" 1*0/1 "1 REFER To PROJECT SWAY l DATUM NTS Cl TY SAM'S CLUB #4835-001 RENTON 901 SOUTH GRADY WAY RENTON, WA 98055 Planning /Building /Public Works Dept. SANITARY SEWER DETAILS SCA14NEU NOV • 7 2003 3 -14 -03 PAGE: oRAwarc C-5.1 SHEET: OF. 11 S INLET J LIQUID J 0 cc a> ' w o �C p � a REINFORCED LEVEL � � TWO -WAY CLEANOUT PRECAST 1 TYP OF z CONCRETE N o SQL WATERTIGHT NOTES: 7 1. PROVIDE SAMPLING PORT DOWNSTREAM O F CONJUNCTURE WITH MAIN SANITARY SEWER. 4% A 04 2. REFER TO PLUMBING PLAN FOR PIPE SIZES. left 3. PROVIDE UTILITY VAULT MODEL 4484 -GA AND 2/3 DISTANCE 1/3 DISTANCE BED OF UNDISTURBED 612 -GA GREASE INTERCEPTORS, REF 1 -P1. EARTH OR COMPACTED DETAIL SHOWS GENERAL SCHEMATIC REQUIREMENTS. CONTRACTOR SHALL SUBMIT SAND BACKFILL 4 " -6" PROPOSED INTERCEPTOR INSTALLATION PLANS AND SPECIFICATIONS TO AUTHORITIES HAVING JURISDICTION FOR APPROVAL BEFORE ACQUISITION OF INTERCEPTOR. PROVIDE INTERCEPTOR WITH ADEQUATE STRUCTURAL STRENGTH TO ACCOMMODATE VEHICULAR TRAFFIC AT INSTALLATION LOCATION. NOTE: THIS DETAIL IS SHOWN FAR REFERENCE ONLY. SEE ARCHITECTURAL /MECHANICAL PLANS. PRECAST GREASE INTERCEPTOR -Z MP07B 11.30.01 " ARGM MSEN C.E. : NONE JRG 3 FINAL PERMIT COMMENTS RESIMITTAL M AND 5 703 �w": JKH 2 PERMIT COMMEWTS RESUBMITTAL PACLAND 4 18 03 CHECKM�.� AT --� FULL F P NOT ONE INCH N0. REVISION BY DATE APPR JRG WALE A�0R01Na'' I. i VERTICAL: NAVO IM. NJ 2123 ELEVATION 45.11 FEET HOR1zowm- P" 1*0/1 "1 REFER To PROJECT SWAY l DATUM NTS Cl TY SAM'S CLUB #4835-001 RENTON 901 SOUTH GRADY WAY RENTON, WA 98055 Planning /Building /Public Works Dept. SANITARY SEWER DETAILS SCA14NEU NOV • 7 2003 3 -14 -03 PAGE: oRAwarc C-5.1 SHEET: OF. 11 S N lJ 0 cc a> ' w o �C p a , N lJ