PORTION OF THE N.E. 1/4, OF SEC. 15, TWN 23 N., RGE 5 E., W.M.
CITY OF RENTON, WASHINGTON
MANHOLE FRAME AND COVER
SEE DRAWING BR29 3/4" SQUARES SPACED - 3/4"
ADJUSTMENT (4" MIN.) AS INDICATED - HT. 1/8"
CONE ❑ ❑
1n„
MAX. PIPE SIZE - 21" I.D.
LADDER -STD. ALUMINUM
OR GALVANIZED STEEL
❑ Li ❑ —F1/2
RUBBER GASKETED JOINTS
❑ 0 ❑❑ ❑ ❑ —r
IN ACCORDANCE WITH ASTM C -443
❑ ❑ ❑ 1>>
STEPS - 3/4" DEFORMED BAR
—�
STEPS SHALL BE INCLUDED
7
RAISE-1/2"
CONCRETE RISER BY PIPE INC.,
2. STEPS ARE TO BE IN PLACE BEFORE MANHOLE SECTIONS
WIDE BORDER
OR APPROVED EQUAL
PRECAST BASE SECTION
1"
1n„
MAX. PIPE SIZE - 21" I.D.
LADDER -STD. ALUMINUM
OR GALVANIZED STEEL
NOTES: 1 -1/4"
1/2') 2"
`5/8"
CONCRETE SHELF
1, STEPS TO BE 3/4" 0 DEFORMED BAR GALVANIZED SAFETY
—�
STEPS OR EQUAL
7
2d /_�
2. STEPS ARE TO BE IN PLACE BEFORE MANHOLE SECTIONS
ALL JOINTS SHALL BE GROUTED. 8
PRECAST BASE SECTION
ARE INSTALLED.
I 7' I
6. S
SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR
OR CAST IN SHELF.
3. CASTING TO BE PER DRAWING BR29.
SANITARY MANHOLE TYPICAL DETAIL
NOT TO SCALE
1:3:5 MIX
CONCRETE
BLOCKING
6" BUILDING SEWER PIPE
4_ MANHOLE SECTIONS TO BE OF REINFORCED PRECAST
CONCRETE.
5. A
ALL JOINTS SHALL BE GROUTED. 8
8>'
6. S
SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR
SURFACES, INCLUDING CHANNELING, COATED (SEALED)
15"
WITH A HIGH SOLIDS URETHANE COATING; 1
WASSER -MC- CONSEAL OR APPROVED EQUAL;
CAST IRON RING AND COVER
COLOR OF COATING SHALL BE WHITE. C
7. R
RUBBER GASKETED JOINTS SHALL BE IN CONFORMANCE
8. C
WITH ASTM C -443. N
NOTE:
DIAMETER OF THE LARGEST PIPE. ` 2
2' -0" SQUARE CONCRETE, CLASS 3000, PAD AROUND
9. '
'CONNECTIONS TO MANHOLE SHALL BE MADE USING GPK R
RING AND COVER.
ADAPTOR, KOR -N -SEAL BOOTS OR APPROVED EQUAL. I
IN ASPHALT ROADWAYS RESTORE AROUND CLEANOUT RING
AND COVER AS REQUIRED BY STANDARD DETAIL DRAWING BR36.
PROPERTY LINE
C-0-
o FUTURE
BUILDING SEWER
W
"-2x_4" STUD SERVICE MARKER PAINT UPPER
-TEE WITH 6" SIDE OUTLET } PORTION WHITE ANS STENCIL ON ,SIDE
F WORDING "SEWER ": WITH 3" HIGH BLACK LETTERS.
AND #6 'WIRE WRAPPED AROUND THE STUD AND
6" SIDE SEWER AND BUILDING SEWER o EXTENDED TO THE TOP OF THE STUD.
0
a UNLESS OTHERWISE APPROVED BY THE CITY, MAKE TAP THROUGH CAST
IRON SADDLE SECURED TO SEWER MAIN WITH STAINLESS STEEL' BANDS
WHEN CONNECTING NEW SIDE SEWERS TO EXISTING MAIN.
60" ALLOWABLE MAX. VITRIFIED CLAY, PLAIN AND REINFORCED' CONCRETE, D1 PIPE AND C1
iC FOR CAST IRON PIPE PIPE SEWER MAINS ARE TO BE CORE DRILLED
rOR DUCTILE IRON PIPE.
6" SIDE OUTLET TEE
SEWER MAIN
6" MIN.
CONCRETE BLOCKING ANGLE
OF TEE AT MAIN OVER 25
ELEVATION
NG�-Eg o�ONG
GPI GR�� 2% MIN SLOPE
1 HORIZONTAL
SEWER MAIN
TYPICAL SIDE SEWER ELEVATION
NOTE:
UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2.5' COVER AT PROPERTY
LINE OR 3 -5' LOWER THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER.
STANDARD SIDE SEWER INSTALLATION DETAIL
NOT TO SCALE
ROLL
12 "4
FIBER
PACKIP
45- (1/8)
PIPE MATERIAL AS SPECIFIED
BY THE ENGINEER
PLUG TO BE SEALED
IN SAME MANNER AS
MAIN SEWER JOINTS.
SANITARY SEWER CLEANOUT DETAIL
NOT TO SCALE
SCAN','!�O JUN 222002 Flo'_7-ii us
FR 23.7
CONCRETE
CLASS 3000
j/4„
SANITARY SEWER N07ES AND SPECIRCA77ONS
1. ALL WORK MATERIALS SHALL BE IN CONFORMANCE WITH THE
STANDARDS AND SPECIFICATION OF THE CITY OF RENTON UTILITY
DEPARTMENT AND THE LATEST EDITION OF THE WSDOT/APWA
STANDARDS. AND SPECIFICATIONS
Z ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH STANDARD
SPECIFICATIONS FOR MUNICIPAL PUBLIC WORKS CONSTRUCTION"
PREPARED BY WASHINGTON. STATE CHAPTER AMERICAN PUBLIC
WORKS ASSOCIATION; LATEST EDITION (APWA) AND CITY OF
RENTON. STANDARD SPEC /FICAVONS
J. ALL LOCATIONS OF EXIS7ING UTILITIES SHOWN ARE
APPROXIMATE AND IT SHALL BE THE CONTRACTOR'S
RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO
AS TO AMID. DAMAGE OR. DISTURBANCE.
4. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS
METHODS AND SEQUENCES OF CONSTRUCTION AND FOR THE
SAFETY OF WORKERS AND OTHERS ON THE CONSTRUCTION SITE.
5. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO
OBTAIN STREET USE AND ANY OTHER RELATED PERMITS PRIOR TO
ANY CONSTRUCTION.
6. PLANS APPROVED BY THE CITY OF RENTON, PUBLIC WORKS
DEPARTMENT SHALL TAKE PRECEDENCE OVER ALL OTHER PLANS.
7. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB
SITE WHENEVER CONSTRUCTION IS IN PROGRESS.
B. THE CONTRACTOR.. SHALL PROVIDE THE CITY OF RENTON NTH
AN.AS -BUILT DRAWING OF THE SANITARY SEVER SYSTEM, WHICH
HAS BEEN STAMPED AND SIGNED BY A LICENSED PROFESSIONAL
ENGINEER OR LICENSED PROFESSIONAL SURVEYOR.
9. BACKF /LL SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE
PIPE IN LAYERS WITH A. LOOSE. AVERAGE DEPTH OF 6 INCHES,
MAXIMUM DEPTH OF 8 INCHES,. THOROUGHLY TAMPING EACH LAYER
TO 95 PERCENT OF MAXIMUM DENSITY. THESE COMPACTED
LAYERS: MUST EXTEND FOR ONE PIPE DIAMETER ON EACH SIDE OF
THE PIPE OR TO THE SIDE OF THE TRENCH MATERIALS TO
COMPLETE THE FILL ' OVER PIPE SHALL BE THE SAME AS
DESCRIBED '
10. OPEN CUT ROAD CROSSINGS FOR U77UTY TRENCHES ON
EXISTING TRAVELED ROADWAY SHALL BE BACKnLLED WITH
CRUSHED ROCK AND MECHANICALLY COMPACTED. CUTS INTO THE
EXISTING ASPHALT SHALL BE NEATLINE CUT WITH SAW IN A
CONTINUOUS LINE A TEMPORARY MIX PATCH MUST BE PLACED
IMMEDIATELY AFTER BACKRLL AND COMPACTION. A PERMANENT
HOT MIX PATCH SHALL BE PLACED WITHIN 10 DAYS AND SHALL BE
PER CITY OF RENTON CURRENT STANDARDS.
It DATUM SHALL BE CITY OF RENTON, 1988 NAVD.
12. ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR
OTHERWISE STABILIZED TO THE SATISFACTION OF THE DEPARTMENT
FOR THE PREVENTION OF ON -SITE EROSION AFTER THE
COMPLETION. OF CONSTRUCTION.
13. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A
PROPERLY PREPARED. FOUNDATION IN ACCORDANCE WITH SECTION
7 OF THE CURRENT STATE OF WASHINGTON STANDARD
SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCBON. THIS
SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR
THE TOP OF THE FOUNDATION MATERIAL, AS WELL AS PLACEMENT
AND COMPACTION OF REOUIRED BEDDING MATERIAL, TO UNIFORM
-GRADE SO THAT THE ENTIRE LENGTH Of' THE PIPE WILL BE
SUPPORTED ON A UNIFORMLY DENSE,. UNYIELDING BASE. PIPE
BEDDING SHALL BE PEA GRAVEL 6 INCHES ABOVE AND BELOW THE
PIPE.
14. SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PM)
RUBBER GASKETED ASTM D 3034, SDR 35, OR DUCTILE IRON
CLASS 50.
15. IN UNIMPROVED AREAS MANHOLE TO EXTEND MIN144UM 6
INCHES AND MAXIMUM 12 INCHES ABOVE FINISHED GRADE. IN
PAVED' AREA, COVER MUST SLOPE IN ALL DIRECTIONS TO MATCH
PAVING.
$y1VFE
w
'i RECOMMENDED
rti FOR APPROVAL
L
sxPDees a /ao /ofi B—
Cali By
before you CHECKED FOR COMPLIANCE
T CITY STANDARDS
1- 800 -424 - ®55� J��Itu, DATE la -s-o�
UNDERGROUND SERVICE (USA)
AVOID CUTTING UNDERGROUND
UTILITY LINES. IYS COSTLY DATE
EXISTING UTILITY LOCATIONS SHOWN HEREON ARE APPROXIMATE ONLY.
IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE
EXACT. VERTICAL AND HORIZONTAL LOCATION OF ALL EXISTING UNDER-
GROUND UTILITIES PRIOR TO COMMENCING CONSTRUCTION. NO
REPRESENTATION IS MADE THAT ALL EXISTING UTILITIES ARE SHOWN
HEREON. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR UTILITIES
NOT SHOWN OR UTILITIES NOT SHOWN IN THEIR PROPER LOCATION.
CALL BEFORE YOU DIG: 1 -800- 424 -5555.