Loading...
HomeMy WebLinkAboutS-330004fly uj F- 0 cn u.j z 0 jr Ui 0 LLJ uj M m uj w >_ cn Z Ix 0 < F- I < ZZ o 0 Z H < 0 z C) 0 =MEWJ SE 1/4 SEC. 10 9TWP. 23 N. RGE. 5 E. jI Ir DI WATER LINE APN 1023059283 ...... . .... ..... . z 2 MQINliy MAP M to M Z z > 0 U) U) U) SANITARY SIDE SEWER GENERAL NOTES, m 03 1. PRIOR TO INSTALLATION OF A SANITARY SEWER CONNECTION, 'Z. Ld ,N4 < to RENTON PUBLIC WORKS DEPARTMENT. l< %1T8TT 2. TYPES OF PIPE AND FITTINGS THAT CAN BE USED FOR SANITARY =MEWJ SE 1/4 SEC. 10 9TWP. 23 N. RGE. 5 E. jI Ir DI WATER LINE APN 1023059283 ...... . .... ..... . MQINliy MAP NTS lz SANITARY SIDE SEWER GENERAL NOTES, 1. PRIOR TO INSTALLATION OF A SANITARY SEWER CONNECTION, APN 1023059186 A SIDE-SEWER PERMIT MUST BE PURCHASED FROM THE CITY OF RENTON PUBLIC WORKS DEPARTMENT. l< 2. TYPES OF PIPE AND FITTINGS THAT CAN BE USED FOR SANITARY SEWERS SHALL BE APPROVED BY THE DEPARTMENT OF PUBLIC WORKS. RUBBER OR NEOPRENE GASKETS AS SPECIFIED BY THE MANUFACTURER, SHALL BE USED ON JOINTS. 3. A MINIMUM GRADE OF 2% (1/4 PER FOOT) MUST BE MAINTAINED WITH e PIPE. IN THE EVENT A 2% GRADE CANNOT BE MAINTAINED. THE OWNER MUST GRANT A GRADE RELEASE TO THE CITY AND THEN CAN INSTALL 6" PIPE AT A GRADE OF 1X 4. FOR INSPECTION OF SIDE SEWER, CALL 24 HOURS IN ADVANCE, 277-5570. SITE MUST BE READY FOR INSPECTION AND REPRESENTATIVE ON SITE WHEN INSPECTOR ARRIVES AT APPOINTED TIME. SIDE SEWER AND STUB APN 1023059264 SHALL BE TESTED PER CITY SPECIFICATIONS. MAKE THE CONNECTION AT THE HOUSE. DO NOT BACKFILL THE DITCH UNTIL APPROVAL IS GIVEN BY THE INSPECTOR. FINAL APPROVAL WILL BE GRANTED AFTER THE EXISTING SEPTIC TANK HAS BEEN PUMPED OUT AND FILLED WITH SAND. 5. INSTALL SIDE SEWER WITH 2' MINIMUM COVER. W COVER IS ALLOWED AT THE HOUSE IF OUTLET IS SHALLOW. 6. IF SIDE SEWER STUB IS NOT AVAILABLE. THE OWNER SHALL 10 BE RESPONSIBLE FOR ITS INSTALLATION. THE SIDE SEWER SHALL BE A MINIMUM IN SIZE. IF TEE IS NOT AVAILABLE, THE MAIN SEVER LINE MUST BE TAPPED SEVER APN 1023059403 THRU A CAST IRON SADDLE. ALL WORK WITHIN STREET RIGHT-OF-WAY SHALL BE DONE BY A LICENSED CUT AND CAP AND BONDED CONTRACTOR. EXISTING LINE 7• ALL WORK SHALL BE ACCOMPLISHED IN ACCORDANCE WITH THE WASHINGTON INDUSTRIAL SAFETY AND HEALTH ACT. (WISHA) APN 1023059254 TRENCH RESTORATION 8. ALL FOR SIDE SEWERS IN THE PUBLIC 7 RIGHT-OF-WAY SHALL CONFORM TO THE MOST CURRENT TRENCH EX. 12" SEWER RESTORATION REQUIREMENTS AS SHOWN ON DWG. #HR-23. t (HONEY BROOKE V) 9. ALL BUILDING SEWER AND SIDE SEWERS SHALL HAVE EXISTING SEWER BEDDING IN ACCORDANCE WITH DRAWING SWISC OR BRO9 AS APPLICABLE. EXISTING F.H. LOCATION 10. THERE SHALL BE A MINIMUM 10 FOOT HORIZONTAL SEPARATION ABANDONED 8" BETWEEN SANITARY SIDE SEWERS AND WATER SERVICES AND A MINIMUM 5 FOOT HORIZONTAL SEPARATION BETWEEN SANITARY SIDE STEEL WATER SEWERS AND ALL OTHER UTILITIES. CT, LEGAL DESCRIPTION. EXISTING SSMH-3024 (DRS), RIM=454.46 (NAVD 88) LOTS 1-2, KING COUNTY SHORT PLAT NO. 480111, RECORDING NO. IE (12"PIPE)=444.86 (NAVD 88) 8206180434, SECTION 10, TOWNSHIP 23 NORTH, RANGE 5 EAST OF (HONEY BROOKE V) APN 1023059281 NWA V SWVk SE• TRACT B, SHORT PLAT NO. 1274035 RECORDING NO. 7601'210497 Ahlb TRACT A. KING COUNTY SHORT P9t NO. 1274035, RECORDING NO. 7601210467 EXISTING 8" DI WATER MAIN VERTICAL DATUM: CITY OF RENTON NAVD 88 t APN 1023059452 RENT-1851 ELEV. = 398.55 IT IS A BRASS DISK SET IN A DRILL HOLE IN THE CENTER OF THE CONCRETE STREET SURFACE IN THE CENTER OF THE INTERSECTION AT THE SOUTH QUARTER CORNER OF SECTION. EXISTING 12" SEWER (HONEY BROOKE V) -1907 RENT ELEV. = 472.68 AT RENTON, AT HOUSE NUMBER 12014 HOQUIAM AVENUE. A 0 JIL-7-07 —wwwwr0r- ENGINEERS PLANNERS 119W mr lov'r mow z SURVEYORS EXPIRES 10/11/6PC3 DRS PROJECT NO. 05286 M:\05\286\plots\2\AS BUILT\2AB-14-3SS5286.dwg 12/7/2007 3:22:29 PM PST COPYRIGHT @ 2005, D.R. STRONG CONSULTING ENGINEERS INC. A N I T I A OrRo'l