HomeMy WebLinkAboutS-335502�V V / MM 4' 0 Q �7 C) Nx o a N F 0 x 0 N ,p O o , g = rI E I (n J O f" U w -H W d w O N x 1 �o N 24 "X 24" COMM. CLS. CONCRETE BLOCK POURED AROUND CONNECTION TO MAIN ­1 6" ON 6" Y BRANCH SW 1/4 OF THE NE 1/4 SEC. 10, TWN. 23N., RGE 5 E., W.M. CITY OF RENTON, WASHINGTON NOTE: DO NOT USE WITHOUT WRITTEN APPROVAL OF THE WASTEWATER UTILITY. NOTE: TO RAISE TO GRADE USE STANDARD 6" SEWER PIPE LONG 6" 1/8 BEND STANDARD 6" X MAIN SIZE TEE SEWER MAIN SIDE SEWER RISER CONNECTION TO SEWER MAIN 0*', ADOPTED .� OF RENTON STANDARD PLANS ISf DATE: 12/96 DWG. NAME: BR08 SP PAGE: B081 PROPERTY LINE MORTAR FILLET MANHOLE FRAME AND COVER N.T.S. 1/2" OVERLAY UPER KING COUTYN STANDARDS SEE DRAWING BR29 NOTES: ADJUSTMENT (4" MIN.) 1. STEPS TO BE 3/4" 4 DEFORMED BAR GALVANIZED SAFETY CONE STEPS OR EQUAL. 2. STEPS ARE TO BE IN PLACE BEFORE MANHOLE SECTIONS ARE INSTALLED. FUTURE 3. CASTING TO BE PER DRAWING BR29. TS RUBBER GASKETED JOIN TS 4. MANHOLE SECTIONS TO BE OF REINFORCED PRECAST IN ACCORDANCE WITH C -443 CONCRETE. BUILDING SEWER 5. ALL JOINTS SHALL BE GROUTED. STEPS — 3/4" DEFORMED BAR 6. SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR STEPS SHALL BE INCLUDED SURFACES, INCLUDING CHANNELING, COATED (SEALED) WITH A HIGH SOLIDS URETHANE COATING; CONCRETE RISER BY PIPE INC., WASSER MC— CONSEAL OR APPROVED EQUAL; OR APPROVED EQUAL. COLOR OF COATING SHALL BE WHITE. • SEE DWG# HR -05 FOR MINIMUM STANDARDS 7. RUBBER GASKETED JOINTS SHALL BE IN CONFORMANCE WITH ASTM C -443. RECOMMENDED 8. CHANNEL HEIGHT SHALL BE A MINIMUM OF 3/4 THE INSIDE DIAMETER OF THE LARGEST PIPE. 6" SIDE SEWER AND BUILDING SEWER 9. CONNECTIONS TO MANHOLE SHALL BE MADE USING GPK MAX. PIPE SIZE — 21" I.D. ADAPTOR, KOR —N —SEAL BOOTS OR APPROVED EQUAL. LADDER —STD. ALUMINUM Of a_ OR GALVANIZED STEEL UNLESS OTHERWISE APPROVED BY THE CITY, MAKE TAP THROUGH CAST CONCRETE SHELF DATE PRECAST BASE SECTION IRON SADDLE SECURED TO SEWER MAIN WITH STAINLESS STEEL BANDS OR CAST IN SHELF. AVOID CUTTING UNDERGROUND UTIUTY UNES. IT'S COSTLY 6" MIN. i---I MIN. (TYP) SANITARY MANHOLE TYPICAL DETAIL NOT TO SCALE 1:3:5 MIX ap \l \�N)NG OOCKING OG BL � GONGFL 2% MIN SLOPE HORIZONTAL 6" SIDE OUTLET TEE } SEWER MAIN SEWER MAIN 6" MIN. CONCRETE BLOCKING ANGLE OF TEE AT MAIN OVER 25 TYPICAL SIDE SEWER ELEVATION STANDARD SIDE SEWER INSTALLATION ELEVATION (SEWER MAIN TO PROPERTY LINE) NOTE: U*tj� ADOPTED UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2.5' COVER AT PROPERTY CITY OF RENTON LINE OR 3 -5' LOWER THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER. STANDARD PLANS LST DATE: 12/96 10/17/96 Edited note. FRJPP�j DATE REVISION DWG. NAME: BR39 SP PAGE: 13078 SANITARY MANHOLE TYPICAL DETAIL (Y p ADOPTED CITY OF RENTON STANDARD PLANS LSf DATE: 12/96 DWG. NAME: BR28 SP PAGE: B071 �.f t' 1' 1' IMIN MINI MIN IMIN MINI I I N.T.S. 1/2" OVERLAY UPER KING COUTYN STANDARDS 6' -0" o . FACE OF CURB OR ........... .............................. .. _ FUTURE 6" BUILDING SEWER PIPE 1 PE 2" CLASS 'B' �ACP CLASS 'E' OR 'B'� p uWA9 6" URFACINGDTOP COURSE CENTER LINE OR LANE LINE CRU HED ROCK, FLOWABLE FILL ,eq OR AS REQUIRED BY ENGINEER 17STis' L BUILDING SEWER 6.5' MIN. z \-2"x 4" STUD SERVICE MARKER PAINT UPPER TYPICAL PATCH FOR .FLEXIBLE -TEE WITH 6" SIDE OUTLET -I PAVEMENT WHEN PERPENDICULAR TO PORTION WHITE ANS STENCIL ON SIDE • SEE DWG# HR -05 FOR MINIMUM STANDARDS r WORDING "SEWER" WITH 3" HIGH BLACK LETTERS. RECOMMENDED [If AND #6 WIRE WRAPPED AROUND THE STUD AND 6" SIDE SEWER AND BUILDING SEWER a- O BY EXTENDED TO THE TOP OF THE STUD. Of a_ LWTE UNLESS OTHERWISE APPROVED BY THE CITY, MAKE TAP THROUGH CAST BY DATE C a" before you d2fAva 45 ® �� D�9� a G 55,55 1- 800- 4,Z4- JrJ«JJ IRON SADDLE SECURED TO SEWER MAIN WITH STAINLESS STEEL BANDS AVOID CUTTING UNDERGROUND UTIUTY UNES. IT'S COSTLY UNDERGROUND SERVICE (USA) WHEN CONNECTING NEW SIDE SEWERS TO EXISTING MAIN. eo:5- 3s5sov � scnN�p ,r� 222am VITRIFIED CLAY, PLAIN AND REINFORCED CONCRETE, D1 PIPE AND U1 60" ALLOWABLE MAX. PIPE SEWER MAINS ARE TO BE CORE DRILLED FOR CAST IRON PIPE OR DUCTILE IRON PIPE. 1:3:5 MIX ap \l \�N)NG OOCKING OG BL � GONGFL 2% MIN SLOPE HORIZONTAL 6" SIDE OUTLET TEE } SEWER MAIN SEWER MAIN 6" MIN. CONCRETE BLOCKING ANGLE OF TEE AT MAIN OVER 25 TYPICAL SIDE SEWER ELEVATION STANDARD SIDE SEWER INSTALLATION ELEVATION (SEWER MAIN TO PROPERTY LINE) NOTE: U*tj� ADOPTED UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2.5' COVER AT PROPERTY CITY OF RENTON LINE OR 3 -5' LOWER THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER. STANDARD PLANS LST DATE: 12/96 10/17/96 Edited note. FRJPP�j DATE REVISION DWG. NAME: BR39 SP PAGE: 13078 SANITARY MANHOLE TYPICAL DETAIL (Y p ADOPTED CITY OF RENTON STANDARD PLANS LSf DATE: 12/96 DWG. NAME: BR28 SP PAGE: B071 �.f t' 1' 1' IMIN MINI MIN IMIN MINI I I N.T.S. 1/2" OVERLAY UPER KING COUTYN STANDARDS 6.5' MIN. �Mt' 1' 2.5' —I t' 1' IN(MINI MIN MINIMIN 2" CLASS '8'—/ .... .... .... . FACE OF CURB OR ........... .............................. .. _ EDGE OF PAVEMENT XIN `2" TO 6" CLASS 'E OR CLASS 'B' PE 2" CLASS 'B' �ACP CLASS 'E' OR 'B'� p uWA9 6" URFACINGDTOP COURSE CENTER LINE OR LANE LINE CRU HED ROCK, FLOWABLE FILL ,eq OR AS REQUIRED BY ENGINEER 17STis' L TONAL Evnm 11/30/06 6.5' MIN. OF GRIND OR2SAWCUTi AND REMOVE TYPICAL PATCH FOR .FLEXIBLE PAVEMENT WHEN PERPENDICULAR TO • SEE DWG# HR -05 FOR MINIMUM STANDARDS ROADWAY CENTERLINE RECOMMENDED CHECKED FOR COMPLIANCE FOR APPROVAL TO CITY STANDARDS BY DME LWTE BY DATE C a" before you d2fAva 45 ® �� D�9� a G 55,55 1- 800- 4,Z4- JrJ«JJ MOTE: EXISTING UTILITY LOCATIONS SHOWN HEREON ARE APPROXIMATE ONLY. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE EXACT VERTICAL AND HORIZONTAL LOCATION OF ALL EXISTING UNDER - GROUND UTILITIES PRIOR TO COMMENCING EXISTING CONSTRUCTION. NO REPRESENTATION IS MADE THAT ALL EXISTING UTILITIES ARE SHOWN HEREON. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR UTILITIES NOT SHOWN OR UTILITIES NOT SHOWN IN THEIR PROPER LOCATION. CALL BEFORE YOU DIG: 1 -.,00- 424 -5555 AVOID CUTTING UNDERGROUND UTIUTY UNES. IT'S COSTLY UNDERGROUND SERVICE (USA) eo:5- 3s5sov � scnN�p ,r� 222am