Loading...
HomeMy WebLinkAboutS-336307W Q z U Ld O ry d w W J L2 M Cif I - C'7 CIO i TL# 143765 -0150 1 835 -139th AVE SE . / 15 I 11843 -139th AVE SE 11847 -139th AVE SE NO ADDRESS N TL# 143765 -0140 I I 14 7L# 143765 - 0130 / 7L# 143765 -0120 7L# 102305 -9409 I I 13 12 TRACT E SD RIM = 428.30 / (n c — EXIST. 8" W (WD #90) I IE -424.1 15 "CMP I I J --_ _ _ __ 432 / W 430 ----_ -- _ --___ - -"-- 3 -12 "DEC TWIN IE =423.0 I I x ❑ a� W gap OHL -- - _ _ 6 DEC I i -''.429 -� (J / NOT SHOWN ON P g29 430 431 00 I 42�, MAP GRAVEL 423 424 G S TA . 426 S07 °01'02 "W STA. 25+00 N S _ TI 13 426 + A= 6 °58'59" (� -105 LF 16" Dl. CL 52 W /PO LYWRAP -N 12- SS -"" �- - ' _ L= 195.00' 27 +00 CB RIM-428.85 --- —� —' — 429 IE 15 "CPEP(S)= 424.20 " 9 428 ®® H L ry SSOdI --- -"'_ ---- -- -- ----_ w g2, S.SMH jff ----_ 427 _ ---- �— f -- --__ EX. 16" DI (W-2716) EXIS 16" GV ( EXIST. 12" GV (� EFLECT PIPE JOINT 22' RT IN VAULT IN VAULT ROM STA 23 +00 TO 25' RT @24+00 B E FENCE "DEC g ' SD 3 W 8 DEC g "DEC " "DEC 3 2 8 CONIC WALK NOTE: ANY NON -PAVED AREAS THAT ARE x 8 "DEC 8 DEC $ "DEC ,""'__'--- "DEC — DISTURBED SHALL BE RESTORED TO - 6' CB RIM = 428.53 8 8 "DEC 8 "DEC 8 "DEC Z ORIGINAL CONDITION OR BETTER STA. 24 +05, RT. 25' �� E 15 "CPEP(N)_423.58 "CPEP(S)- CB RIM = 427.33 r/ \ n- l CONNECT TO EXISTING 16" DI WATER 11 IE 15 423.48 IE 15 "CPEP(N)= 422.83 IE 15 "CPEP(W)= 422.73 a 9 `J SEE CONNECTION DETAIL #3 ON SHEE 10 OF TL# 238520 -0050 1 - 16" SLEEVE (MJ) 5 N J � FL# 238520- 0040 _ N ' 0 � 16" DI SPOOLS WMH= 427.50 �^ � o 4 TL# 238520 -0030 TL# 238520 -0020 TOP 16" DI PIPE =423.3 C7 C� c N� 75 WMH= 427.18 ° y � SSM COR# 93 3 2 TOP 12" DI PIPE =422.7 0 z RIM= 26.91 NOTE: 30.00' 30.00' Z CL c NL 12 °PVC E -w)= 416.01 BORING 2, LOCATED STA 20 +05) WHICH JUST TAPPED BELOW THE TILL INTO THE UNDERLYING CB RIM- 426.64 IE 15 "CPEP(N)= 422.54 OUTWASH AT APPROX DEPTH 20.5' IE 15 "CPEP(W)= 422.34 GAS WHICH MAY HAVE BEEN METH DD � IN THE OUTWASH. THIS WILL NOT LIKELY IMPACT CONSTRUCTION DUE TO THE THICKNESS OF LOW PERMEABLE SOILS CAPPING THE OUTWASH. 7L# 238520 -0010 CONTRACTOR SHOULD MONITOR FOR POTENTIAL 1 PRESENCE OF GAS IN THE TRENCH EXCAVATION AT THE TIME OF CONSTRUCTION. 27 +00 26 +00 ............................... 25 +00 3 24 +00 .......................................................... = RIM 426 91 23 +00 6 01 CL CHN 12 (- ) =41 . STA. _24 +05 : - - 430 . : CONN =ECT TO EXISTING 16" W = . : 430. ..................... .................. : GRADE AT CENTERLINE : : 4 MIN. COVER (TYP.) 425 : ±105 LF 16".-.Dl CL. 52- W POLYW:RAP EX: 16"' :DIP (W= 2:716) ............................ : .................... ..........:..... :42 ....... S- 336307 415 = ' _m �d 0 J O 0 00