HomeMy WebLinkAboutS-337501W zz U W 'o x a 119 ti M M ti N a T N 197983.00 E 1303359.60 N � O 0606 lIr- B' 11 II =ww 30 v¢v�Nnz co (n Lu v` v LEX GND N W I I I LEX 12 "SS I(PVC) 158.7' 0 60" SADDLE W1 24" 0' -TEMP RELOCATE EX REQ'D FOR OUTLET STRUCTURE CONSTRUCTION AFTER OUTLET STRUCT COMPLETION, CONN 6" SS TO NEW SS MHO CONNECT TO EX 1 N 198054.30 E 1303403.02 z Z Ad : U M mom OD cl Q O z Uo C'4 II II II .Nro 11 www ;.N.O. -J. —ice, O w3(nz \W?z NN rz3cn vUZI -.- C al w CHAIN LINK CONST FENCE / STRUCTURE EXCAVATION LIMIT SEE D�,G DT1 REMOI SECT OF EX 36 "SD AS R Q'D FOR CONNECTION RESTORE WHEN OUTLET _ STRJ URE COMPLETE 24 "- 2&2 BND 7 r--- - - - - -- PLAN SCALE IN FEET TAX LOT 2924059015 36" PLUG W/ 24" FLOW THRU _ 24" PIPE cv L24"-- 22Y' BND I REMOVE /ABANDON 78'- 12 "SS �.. 14S'- 19 "cc FOR WATER MAIN MODIFICATION SEE DWG C4 REMOVE 68!- 12 "SS N 198120.20 E 1303443.16 r M r�C5 m N EX 24 "SD TEMP ECOLOGY BLOCKS PROTECT EX 12"W SEE DWG C6 M O N N [EX GND EST FINISHED GRADE ( N (SEAHAWK SITE GRADINGI PLAN) A �' 4" THK ETHAFOAM PAD - - S=0.23% I/ OVER 4- 36 "SD I I —145'- 12 "SS (PVC) ® 6-9.22% 36"SD IE= 18.09 -j 36 "SD I IE =18.39 SECTION n HORIZ: 1 " =10' C3 VERT: 1"=5' - REMOVE/ IE =18.39 78'- 12 "SS 24 "SD REMOVE 68'- 12 "SS (PV( _ SU.P/EYEO: 6fllE M14ENU0 FOR APPROVA! +roaiz0 `wn ie0°3%1991 �� _... — 9 sroxEO •. CITY OF By, ____ __ Date- R. HERMES LA By'____ __ -_ Date +__ °__'__ °"""'+ RENTON 1231 FRYAR AVENUE __ J. BETZVOG W SUMNER, WASHINGTON 98390 By,____ ____ _ Do, tB- ONE ixcx DATUMI T. 253.883.5128 F. 253.063.0906 _ - - -- -- _ — CNECNEb. IF NOT ONE MCx B _ ,I, AT+va w,2 Planning /Building /Public Works Dept. WYM•.Pefeme4l%.COm y _ Date'_ ... ........ N.4E XCORWNGLY NO. REVISION BY DATE APPR ""� ^� C G CONNECT TO EX MH N 198178.95 E 1303476.60 N N r yp 10 CONSTRUCTION NOTES: 1. NEW SANITARY SEWER MANHOLE SHALL CONFORM TO CITY OF RENTON STD PLAN B071. 2. OUTSIDE DROP CONNECTION SHALL CONFORM TO CITY OF RENTON STANDARD PLAN 8075. GENERAL: 1. THE CONTRACTOR SHALL PROTECT ALL PRIVATE AND PUBLIC UTILITIES FROM DAMAGE WHEN TRENCHING ACROSS OR BESIDE THESE UTILITIES. 2. PIPE TRENCH SHALL BE IN ACCORDANCE WITH SECTIONSeANDe. DT5 DT5 3. EXCAVATION ON SEAHAWK SITE (WEST OF BNSF R /W) WILL ENCOUNTER EITHER A SOIL CAP INDICATOR FABRIC OR A 30 MIL MEMBRANE CAP AS SHOWN ON SECTIONSeANDe. DT5 DT5 CONTRACTOR SHALL EXPOSE CAP MATERIAL(S), AND CUT BEFORE CONTINUING EXCAVATION FOR PIPELINES OR STRUCTURES. POSSIBLE CONST SEQUENCE FOR TEMP SD DIVERSION: 1. INSTALL 60" SADDLE W/ 24" OUTLET (FL) 2. INSTALL 24" PIPE (TEMP) 3. INSTALL 36" PLUG W/ 24" FLOW THRU 4. WHEN OUTLET STRUCTURE COMPLETE, REMOVE TEMP 24 "SD 5. RESTORE 36 "SD 6. INSTALL 24 "BF ON 24" OUTLET I 2 +50 S=337501 SW 29 -24 -05 As - 13v1L:r DIM RIPLEY LANE N. STORM SYSTEM IMPROVEMENT PROJECT 3/21/08 f1E1DBWN: SANITARY SEWER IMPROVEMENTS (SS) DR3mN6 M TEMP SD DIVERSION C3 SS STA', 0 +00 TO STA 2 +28 OF,n