HomeMy WebLinkAboutS-338802I
U)
U)
0L
(L
IL
(D
Z
C)
Z
W
r
F-
<
PRIVATE DDCV4 8- MINIMUM (SEk CITY LEGEND:
STANDARD DETAIL B-100). FINA L S OF
DDCV4 TO BE DETERMINED BY 7 I <
FIRE CATCH BASIN, TYPE I
,
SPRINKLER DESIGNER >
/' (i) CATCH BASIN, TYPE 2
PIV 1_8` GATE VALVE (MJxMi)--�
STORM CLEANOUT
< STORM DRAIN LINE
WATER QUALITY VAULT
SERVICE PER, N
2' WATER MINIMUM (SEE CITY
RENTON S7D,-' STA. 12+7Z90, 45.5'L PRI VA TE D6 C VA SANITARY SEWER CLEANOUT
S TA. 11+55:45, 12.10'R-\ SERVICE PER DETAIL B��070 11, 8" Mi PLUG
I-16"Xr TEE (FL) RENTON STD. -THRUST BLOCK STANDARD DETAIL 0-100). FINAL SIZE OF SANITARY SEWER MANHOLE
Z -GATE VALVE (FLxMJ) DETAIL B-IOZI DDCVA TO BE DETERMINED BY FIRE GREASE INTERCEPTOR
2-10* SPRINKLER DESIGNER.
ti 1-8, CATS VALVE (FLxMJ) I )
P/ WATER VALVE
1-THRUST BLOCK FDC -STA -113+15;60, 17.40'L
"I FDC WATER METER
k (b 1-8' .45' BEN6'(MJ)
j -4 1- IHRUSrtBLOCK
lJl FIRE HYDRANT
\��R T�Hl 0 TH PLACE 21 I-L WATER POST INDICATOR VALVE W1 BLOWOFF
0 1 0.88 (SEE CITY STD an POST INDICATOR VALVE W1 CAP
RiLF SS DETAILB107.2) A RE DEPT CONNECTION
_�:�STA13+31,35, 14.15' L
FIRE S x.85% 12-�OO 1-10 45- BEND DOUBLE CHECK VALVE
60LF 1- THRUST BLOCK
REDUCER
112 LF 10-01 CL 52 - - - - - - - - WATER LINE EASEMENT
00 ROW
52 w�o i-u a 142 LF 101D.I.
- - - - - - - - - - - - - - -C&-52-
L 41 CL 52 UTILITY TRENCH
STA 11+1229, 8.92
RIM 29.18
L
INVERT-OUT 16.27 SW - STA-1,5.+Z95 5. 5'L
3�- . -NE SE --b
INVERT IN 16 j� 2' WATER PIV
1-10'x8" IiE
161�1 All. PER - FLxMJ ADAPTOR,
,b, 1-10 Fp 0. RENTON SID. 2-10- GATE VALVES (F4MJ)
B,IOZ NOTES.
gill DETAIL. STA 1-8" GATE VALVE (FLxM))
TA 11+16.36 2777 R 1+71.32, 5.63 L
1-1HRUST BLOCK
G RIM 29.79 (N 10TH PL)
x5- INVERT 18.75 1. GREASE INTERCEPTORS AND GREASE TRAPS
1 STA 0+84.88, 14.98 L (N)
RIM 28 61
5'R WILL BE INSTALLED BY EACH TENANT UNDER
.01" STA. 11+1245, j
Pit G & BLOC G & CONNECT TO,42' STUB INVERT IN 18.76 E, N STA. 13+08.5, 8.4• R
STA. 12+76.30, 26.90' R
INVERT OUT 18.68 W
SH CITY-z' TON IMPROVEMENT PLANS SEPARATE PERMITS AT A LATER DATE AND
- - I-I . . I I 1 1-10" 45' BEND (MJ) 0
1 -12 °x10° REPUCER (MJ) CO 1-8" AM PLUG 1-THRUST BLOCK SHALL BE SIZED ACCORDING TO UPC GUIDELINES.
r.,10 I-THRUST BLOCK
1-10 SLEEVE ST 11+1714 3388 R 2' WATER
1-10" �POOL (MJ) RIM 29.92 'SERVICE PER
2. CONTRACTOR TO VERIFY INVERT ELEVATIONS
1 10, CAL CROSS (FLxMJ) INVERT 19.00. S3SMH#4 RENTON SID.
STA 12+49.05, 17.27 L -IOZI
CITY S CONNE6601DETA B-116) 17.27 L DETAIL'B OF EXIS77NG STUBS BEFORE CONSTRUCTION
D FLxMJ) RIM 29.02 R I-)
INVERT IN 19.59 N. STA. 12+71.40, 15.00' BEGINS.
1-THRUS CK S TA. 12+77.25,-17(-50' L
INVERT OUT 19.49, W 1 -FIRE HYDRANT ASSEMBLY 7
1-10' GATE VALVE NJ) 1-8- TEE (k)- -
1-8" F7xMJ ADAPTOR 3. ALL ON-SITE SEWER WILL BE PRIVATELY
278- GATE VALVES (FExW) OWNED AND MAINTAINED.
1-7HRUST BLOCK
WATER & SANITARY SEWER #1 PLAN
SCALE., 1"-- 20' C6.1 I
----------------- - - - --
---
u
lu�l ------
SCALE
U no
0 10 20 40
C-4
--- --- --- 40
( FEET
40 - ------ - ------
rn
I INCH = 20 FT
N
to
t6�-
PROFILE SCALE.
HORIZ. 1"=20'
16 r
C4
PROPOSED SURFACE ALONG f VERT. 1"-5'
OF N 107H PLACE
30 30
F
n
I-STA: 114,-74.5 >1� Pz STA'.12+76 STA: 13+19 L A..
g OT 1 2" WATER SERWCE SERWCE 16" STORM D?AIN
B" FIRE
PIPE
12" IN.
F
10"I CL I !STA: 11+12.45 93 41151
STA: 11+55.,ft 10 D.I. CL 52
CONNECT TO EXIS71NG
1112! WATER AIVB i 10"x8* TEE STA: 13+31.35 0' AL
-8
--W-GA GATE VALVE VF- 45' --
20 ° - -- -- 20
SS 030%. 0 1 STA: I3 +02. BEND
I EXISTING StUB 60LF STA: 12+71.40 2" WATER SERVICE
10"X8" TEE STA: 13+15.80
'
4 FIRE SERVICE STA: 13+08,5, lO x8* TEE
45' HORIZ 10- GATE V4' VE Checked for Compliance to City Standards
10 GATE VALVE �,
_E=16 BEND -
Juoti
WATER ER & SANITARY SEWER #2 PROFILE,,
SCALE.- HORIZONTAL 1" 20'
VERTICAL 1'f=5'
- - ----------- --------- - - ------------------------ --- - --------- ------
11+00 11+50 12+00 12+50 13+00 13+50 14+00 15+00
3350 Monte Villa Parkwa
y
Bothell, Washington 98021-897Z THE LANDING 1"=20' A M, CITY OF THE LANDING
HCS
AN RENTON HARVEST PARTNERS
vna
(425)951-4800
(425)951-4600
.- HCS
SRS
ONE NCII
WATER & SEWER PLAN & PROFILE
1 Planning/Building/Public Works Dept.
a,hp-111cco.
Engineers • Surveyors • Landscape Architects
REVISION
BY DATE APPR iavnoveJwIE
LOT 1A
•
SCANNED joy ttm
ROLL
2,01i
FK
420