HomeMy WebLinkAboutS-339906E _N 6d i 0 0 r; 3 °o M z 0 0 0 U az a m a 0 v 2 v° i 0 N STA. 19 +68, 86' LT" __' SANITARY SEWER STUB LOT 3007 W /(X.EAHOUT STA. 19 +51.5, 80' LT. 12" WATER LINE STUB* 12" CAP W/ 2" TEMP, X BLOW -OFF ASSEMBLY THRUST BLOCKS LOT 30 STA. 19+80 50.0' kT., 7 1 - 12" 45' BE N6 ! THRUST BLOC S 12" WATER LINE STUB* } LOT 32 STA. 19 +31 15' LT. 2" AIR /VACUUM RELIEF VALVE V 1 - 12" VERTICAL CROSS (FOR POLLYPIGGING)(MJ X FL) 12" CAP (MJ) WITH 2" BLOW -OFF ASSEMBLY ` SEE RENTON STANDARD DETAIL B114. _ . 19+80 15.0' LT. f - 1212 "x��_ �2 -12 "GV THRUST BLOCKS LOT 32 �. / SEC 25, T 23 N, R 4_E,_ W.M. MsrCy e GRAPHIC SCALE 1 -i.Z"O Of W I / S S�A ao o to 20 40 w STA. 22 +82.5 10.0' LT. T 5uj 23� 114 LF 8 "0 PVC 1 - 12 "x12" TEE (FL X Fl)` gr `31 00 IN FEET D 09.6% 0.8% 3_--19 MJ) :_ s inch 20 tc THRUST BLOCKS x x STA. 22 +75 LOT 31 � 1 - 12" 22.5- ��J X MJ) �/ � I �x EX i W - 8 0 LT 1 - 12" 11.25' BEND I (MJ X MJ) I \ \\ THRUST BLOCKS ,i ` T - w od V CATCH UNE ��/ �4 QJ� MH# 4 i STA. 23 +00, 8.5' RT. STA. 22 +09, 12.5' T p� T@ FIRE HYDRANT ASSEMBLY z 1 (TYP.) 1 - 12" 22.5' BENDI� �� @� v `rS THRUST BLOCKS t 6° T W /6" HYDRANT BARREL 1 V MH# i STA: 21 +50.5 12.5' LT. CONNECT NEW WATER MAIN TO SD \ I - 12" 22.5' BEND ��� x EXISTING 12" WATER LINE STUB - CHES THRUST BLOCKS _ REMOVE EXISTING BLOW OFF. SEE CONNECTION DETAILS, SW ti S 1 RENTON STANDARD DETAIL W 20 00 7 \_S\ .\19 +6 25' SANITARY S� R STUB IE = 15.93 \\ LOT 32 , W /a.IEMOUT I !, D5 LFS O PVC SS,� N89°59'08 "E _ y %i/a z_ c Z �.i-_ -, SIDEWALK (TYP.} IRA t SEE SHEET CR -2.4 FOR STORM DRAINAGE POND INFORMATION. 8116. NOTE E _ '147 LF 12 "4 DI W 'R/ MH# 3 *' U 1 THE MAXIMUM AVAILABLE FIRE FLOW FROM THE NEW 12 -INCH WATER o * - - - - - - - MAIN IS LIMITED TO 2,600 GALLONS PER MINUTE (GPM). ANY / DEVELOPMENT WITHIN THE BOEING LONGACRES PARK THAT HAS A MH# 2S / * x FLOW FLOW DEMAND OVER 2,800 GPM WILL BE REQUIRED TO INSTALL. 1 ADDITIONAL OFF -SITE AND ON -SITE WATER MAIN IMPROVEMENTS, > - X WHICH WILL INCLUDE, BUT NOT BE LIMITED TO, A SECOND 12 -INCH / WATER LINE IN SW 27TH STREET FROM THE EXISTING 12 -INCH WATER % x I LINE IN OAKESDALE AVENUE SW AND THE NEW 12 -INCH LINE SHALL EXTEND TO THE WEST, AND /OR AS REQUIRED TO PROVIDE THE i 1 REQUIRED ARE FLOW DEMAND FOR THE PROPOSED DEVELOPMENTS, IN x CONFORMANCE WITH THE CITY OF RENTON'S DEVELOPMENT I REGULATIONS. i * I �1t;� *" ii l,71 I.i:, � Fq; Ii T,7 ',7''.717 •, MI'J !1 !1 1 MI 1 ° 1 `71 • 1 Mt 1' 'i !1'J I ! M 7 1 ! 1 ' 7 "t `9 - 1 71 7 1 ` 7 F 77' 7'd: ►7' ^71 '1 111 1 1 ° ►'�:7! :1 MI 1 ° 1 MI ` 7 1 °r 7 a ►7• 1 71 1 r• ., 7 .7 °• v al w 1 r •7• �r ., 1• 1 ` 1' ' • 1 ,l;ii •, MI'J 15 e 20 +00 20 +50 21 +00 21 +50 22 +00 22 +50 23 +00 Designed By: Issue Date: MPJ 07/07/08 Drawn By: 3W -3.0 MPJ /WLG RECORD DRAWINGS Checked By: Project No. WED 30950005 L S Cj VA © A ,s6sz6 -"ORAL ce° 606 Columbia St. N.W., Suite 106 T (360) 786 -9500 exF= 6/61109 Olympia, WA 98501 F (360) 786-5267 W PA WD WM LEGEND 24 +00 -1— - CENTER LINE - - RIGHT OF WAY LINE - - PROPERTY LINE - - - - - EASEMENT LINE SS SEWER LINE — SEWER LINE STUB WITH PLUG 0 SEWER MANHOLE W -3. — W —WATER LINE ►F — WATER LINE STUB FIRE HYDRANT 4 W -3. N GATE VALVE W -3. ►i-I THRUST BLOCKING 1 AIR / VACUUM RELIEF VALVE HBO BLOWOFF ASSEMBLY UTILITY NOTES: 1. ALL SANITARY SEWER PIPES TO BE 8 "4 PVC SDR 35. 2. ALL WATER PIPES TO BE POLYWRAPPED 12 "4 DUCTILE IRON CLASS 52. 3. ALL SEWER, STORM AND WATER STUBS TO BE CAPPED AND MARKED PER CITY OF RENTON STANDARDS. *INSTALL 12" MJ CAP WITH 2" TEMPORARY BLOW -OFF ASSEMBLY FOR ALL WATER STUBS TO INDIVIDUAL LOTS. SHACKLE END CAPS TO VALVE AT MAIN LINE. S= 339906 BOEING LONGACRES PARK SANITARY SEWER AND WATER NACRES AVE sw PLAN AND PROFILE 3W -3.0 RENTON, WA a8; U°339907 3- 3399a(0