HomeMy WebLinkAboutS-340002w L' 0 R z 40 �- -0 P4 0 -, 0 Zia ai Z_ a A w 05 0 z 0 z R z rn W 0 z 2 9.1 113.5 MIX CONCRETE BLOCKING F --- f CD 6" BUILDING SEWER PIPE TEE WITH 6" SIDE OUTLET 6" SIDE SEWER AND BUILDING SEWER 60" ALLOWABLE MAX, FOR CAST IRON PIPE OR DUCTILE IRON PIPE, j�� \-6" SIDE OUTLET TEE SEWER MAIN 6" MIN, CONCRETE BLOCKING ANGLE OF TEE AT MAIN OVER 25 ELEVATION L SEWER MAIN PROPERTY LINE FUTURE BUILDING SEWER Lj z \-2//x 4*' STUD SERVICE MARKER PAINT UPPER PORTION WHITE ANS STENCIL ON SIDE I- >_ WORDING //SEWER"/ WITH 3" HIGH BLACK LETTERS, AND #6 WIRE WRAPPED AROUND THE STUD AND n EXTENDED TO THE TOP OF THE STUD, 0 ry a UNLESS OTHERWISE APPROVED BY THE CITY, MAKE TAP THROUGH CAST IRON SADDLE SECURED TO SEWER MAIN WITH STAINLESS STEEL BANDS WHEN CONNECTING NEW SIDE SEWERS TO EXISTING MAIN, VITRIFIED CLAY, PLAIN AND REINFORCED CONCRETE, Dl PIPE AND Cl PIPE SEWER MAINS ARE TO BE CORE DRILLED GON 27. MIN SLOPE HORIZONTAL TYPICAL SIDE SEWER ELEVATION NOTE, UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2.5' COVER AT PROPERTY LINE OR 3-5' LOWER THAN THE LOWEST HOUSE ELEVATI❑N., WHICHEVER IS LOWER, S! z 0 In w z w r. cr- I I K m 6 71 10/17/96 Edited note. DCV AG W O V) L'I wl Lu ADJUSTMENT (4' MIN.) 1, STEPS TO BE 3/4' 0 DEFORMED BAR GALVANIZED SAFETY STEPS OR EQUAL, CONE 2. 0 j 0 _j ARE INSTALLED, 3. CL RUBBER GASKETED JOINTS m U- uj P-4 CONCRETE. 5, to 0 >� r- 6. SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR uj SURFACES, INCLUDING CHANNELING., COATED (SEALED) 0 0 - - to * Z WASSER MC-C❑NSEAL OR APPROVED EQUAL; OR APPROVED EQUAL. olo t[ -ITO? 7. RUBBER GASKETED JOINTS SHALL BE IN CONFORMANCE Z 2_ oc 8. CHANNEL HEIGHT SHALL BE A MINIMUM OF 3/4 THE INSIDE F- _j V) w i i _j DIAMETER OF THE LARGEST PIPE. MAX. PIPE SIZE - 21' I.D. w L' 0 R z 40 �- -0 P4 0 -, 0 Zia ai Z_ a A w 05 0 z 0 z R z rn W 0 z 2 9.1 113.5 MIX CONCRETE BLOCKING F --- f CD 6" BUILDING SEWER PIPE TEE WITH 6" SIDE OUTLET 6" SIDE SEWER AND BUILDING SEWER 60" ALLOWABLE MAX, FOR CAST IRON PIPE OR DUCTILE IRON PIPE, j�� \-6" SIDE OUTLET TEE SEWER MAIN 6" MIN, CONCRETE BLOCKING ANGLE OF TEE AT MAIN OVER 25 ELEVATION L SEWER MAIN PROPERTY LINE FUTURE BUILDING SEWER Lj z \-2//x 4*' STUD SERVICE MARKER PAINT UPPER PORTION WHITE ANS STENCIL ON SIDE I- >_ WORDING //SEWER"/ WITH 3" HIGH BLACK LETTERS, AND #6 WIRE WRAPPED AROUND THE STUD AND n EXTENDED TO THE TOP OF THE STUD, 0 ry a UNLESS OTHERWISE APPROVED BY THE CITY, MAKE TAP THROUGH CAST IRON SADDLE SECURED TO SEWER MAIN WITH STAINLESS STEEL BANDS WHEN CONNECTING NEW SIDE SEWERS TO EXISTING MAIN, VITRIFIED CLAY, PLAIN AND REINFORCED CONCRETE, Dl PIPE AND Cl PIPE SEWER MAINS ARE TO BE CORE DRILLED GON 27. MIN SLOPE HORIZONTAL TYPICAL SIDE SEWER ELEVATION NOTE, UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2.5' COVER AT PROPERTY LINE OR 3-5' LOWER THAN THE LOWEST HOUSE ELEVATI❑N., WHICHEVER IS LOWER, S! z 0 In w z w r. cr- I I K m 6 71 10/17/96 Edited note. DCV AG W O V) L'I wl 2+00 011161 440 9611111 9A TUAf ELE V 420.00 0+00 MORTAR FILLET N. ZrA,l _F 0 SEE DRAWING BR29 NOTES ADJUSTMENT (4' MIN.) 1, STEPS TO BE 3/4' 0 DEFORMED BAR GALVANIZED SAFETY STEPS OR EQUAL, CONE 2. STEPS ARE TO BE IN PLACE BEFORE MANHOLE SECTIONS 0 < 0 _j ARE INSTALLED, 3. CASTING TO BE PER DRAWING BR29, RUBBER GASKETED JOINTS m U- IN ACCORDANCE WITH ASTM C-443 CONCRETE. 5, to 0 >� r- 6. SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR STEPS SHALL BE INCLUDED SURFACES, INCLUDING CHANNELING., COATED (SEALED) 04 +n 0 - - to * CONCRETE RISER BY PIPE INC., WASSER MC-C❑NSEAL OR APPROVED EQUAL; OR APPROVED EQUAL. olo t[ -ITO? 7. RUBBER GASKETED JOINTS SHALL BE IN CONFORMANCE w 01 7>1 8. CHANNEL HEIGHT SHALL BE A MINIMUM OF 3/4 THE INSIDE F- _j V) w i i _j DIAMETER OF THE LARGEST PIPE. MAX. PIPE SIZE - 21' I.D. 9. CONNECTIONS TO MANHOLE SHALL BE MADE USING GPK cn w ADAPTOR, KOR-N-SEAL BOOTS OR APPROVED EQUAL. E 173'-8" PVC 0 0.50X W 2, TYi 8 -54" r Rl�.50 SSMH# 1 INV=42S.2,3 (60y' RIM=4.46.5:h (MATCH PAVING) INV=4M06 (8m) NEW INV=428.20_------__ SEME EX. INV=428.10:k (VERIFY) 1"=20' HORIZ. 1"=5' VERT. co 04 to ui ui to c6 2+00 011161 440 9611111 9A TUAf ELE V 420.00 0+00 MORTAR FILLET N. ZrA,l _F 0 SEE DRAWING BR29 NOTES ADJUSTMENT (4' MIN.) 1, STEPS TO BE 3/4' 0 DEFORMED BAR GALVANIZED SAFETY STEPS OR EQUAL, CONE 2. STEPS ARE TO BE IN PLACE BEFORE MANHOLE SECTIONS ARE INSTALLED, 3. CASTING TO BE PER DRAWING BR29, RUBBER GASKETED JOINTS 4, MANHOLE SECTIONS TO BE OF REINFORCED PRECAST IN ACCORDANCE WITH ASTM C-443 CONCRETE. 5, ALL JOINTS SHALL BE GROUTED. STEPS - 3/4' DEFORMED BAR 6. SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR STEPS SHALL BE INCLUDED SURFACES, INCLUDING CHANNELING., COATED (SEALED) WITH A HIGH SOLIDS URETHANE COATING; CONCRETE RISER BY PIPE INC., WASSER MC-C❑NSEAL OR APPROVED EQUAL; OR APPROVED EQUAL. COLOR OF COATING SHALL BE WHITE, 7. RUBBER GASKETED JOINTS SHALL BE IN CONFORMANCE WITH ASTM C-443, 8. CHANNEL HEIGHT SHALL BE A MINIMUM OF 3/4 THE INSIDE DIAMETER OF THE LARGEST PIPE. MAX. PIPE SIZE - 21' I.D. 9. CONNECTIONS TO MANHOLE SHALL BE MADE USING GPK ADAPTOR, KOR-N-SEAL BOOTS OR APPROVED EQUAL. LADDER—STD. ALUMINUM OR GALVANIZED STEEL CONCRETE SHELF PRECAST BASE SECTION OR CAST IN SHELF, SANITARY MANHOLE TYPICAL DETAIL NOT TO SCALE 10/17/96 EDITED TEXT 3/8/95 ADDED NOTE, EDIT TEXT 2�`m 0" =="ANIE AND _P FER DRAVANS BR29, S-1 PA.-E B074. r. - kI0TF'_-;: AFETY ' _rl STE ::" TO DE 31—': cA DE='3Rk,=D _AF. "42VA ' ',IZED '_ STE S CR EQjA-- qE"-]C'-;: ARE INc;_A__='D. .3 T -_ _'S ARE TO EE IN ='-ACE 3EFORE 10A.KHO-E T_ 3. CAS-4-G -0 =-=-' FE-i DR Asa KG -=::;29. 4. KA "' -i F S-CIONS ID H- HFIlJF'_lKGFD 7. U, -- 1%] k.3 z:HOJI U hI- INTS -IAL_ BE GRC___"D. O 'S 7. czE%,,="R 14A%HQ_=_'5 S-, ,LL ,.LL 1%.-ERIOR SUR7ACES. 1\01-Ml<; (;HANWIIN 1 1 l �SFrI -i)) '.','IH A -11tH SO DS UHI­ IH.A* GO A AG; V., A S s - H. It I­ QUA Cut i F NG l:HA HF III A I Ni 9. li,.Nr 1 11 Ii-.11 SHP, I 131 1A1416'UM J/ I I It TC Sl ':LL BE PrADE LISING GPI" ADAPT07. KOP 4-31AL 11 SANITARY SIW-LOW, MANHOLE n-PE 3 ADOPTED UP, D11 lillillul" STWIA[al PlAKS LST DATE: 01/Cl LIWG. h.Aflll_. Ef"I/2 S F F AG L: 3 DCV AG DCV AG NOTE: EXISTING UTILITY LOCATIONS SHOWN HEREON ARE APPROXIMATE ONLY. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE EXACT VERTICAL AND HORIZONTAL LOCATION OF ALL EXISTING UNDER- GROUND UTILITIES PRIOR TO COMMENCING CONSTRUCTION. NO REPRESENTATION IS MADE THAT ALL EXISTING UTILITIES ARE SHOWN HEREON. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR UTILITIES NOT SHOWN OR UTILITIES NOT SHOWN IN THEIR PROPER LOCATION. CALL BEFORE YOU DIG: 1-800-424-5555.