Loading...
HomeMy WebLinkAboutS-345009A PORTION OF THE NW 1/4 OF SECTION 15, TWP. 23 N., RGE. 5 E., W.M., KING COUNTY, WASHINGTON n EXISTING 12 "0 f NE 2ND CT C.I. WATER MAIN PER i AS -BUILT DWG W -245 p; a `E o 100 +65.04, 23.44' VASHON AVE NE SEE SHEET 1111S -0 STA. LT. SEE SHEET WS -04 3 1 -5 1/4" FIRE HYDRANT ASSEMBLY FLANGE ELEVATION -- 44-1-34 - 4 T� '411.33 , PAD KEY MAP 3 I 1 EL= 405.25 O o° III. W I I ( PAD 2 3 EXISTING SEWER MAIN PER AS -BUILT I ± I Z EL.= 411.25 PAD ` S -435 TO BE REMOVED OR ABANDONED ` II) Lll, a I I I EL.= 409.25 PAD BETWEEN EXISTING S.S.M.H #3 AND - - -- EL.= 407.25 EXISTING S.S.C.O.. REPLACE WITH 263 L.F. D 3 I ( 8 "0 PVC S.S. AS SHOWN. RECONNECT O 20' 10' O 20' 40' ZW UNVERIFIED LOCATION OF EXISTING SIDE SEWERS PER STD PLAN I N t " =zo' HDRIZ. 3/4" WATER SERVICE 7 + SCALE: t " -t0' VERT. JOINT UTILITY EXISTING S.S.C.O. TO BE 407. MAINTAIN UNINTERUPTED SERVICE TO o D. I oo PER DETAIL 320.1 (TYP) REMOVED T EXISTING HOMES CURRENTLY SERVED. PAD �� 3 00 II TRENCH ? I N \� + ._ _ _.± + E1.= 400.75 % - - -- -V ;- �-- :- .. .. °,- IN AI NI MUM , ro a 1 VERTICAL DATUM: .. .. � - - HORIZONTAL SEPARATION - .. .................. ..... ...._ .............. ... R AND SEWER VERTICAL DATUM ND 88. BTEN WATE . .. � .. _ PROJECT BENCHMARK 8 KING COUNTY CONTROL POIN T #6 11 3, W PO NT ME NT103 PUBLISHED ELEVATION = 401.012 FEET. y Z N D Ia. c701 00 G - G o5 c ^` -"� - - - _ - - _ _ �_- - ' --- J W SEE SHEET HC -01 MAP FOR TEMPORARY BENCHMARK LOCATIONS, EXISTING 12 D.I. ,� - I - s 0, s s 1 c G G c - - '-' - - - = N TBM 100 - EXISTING RR SPLICE UP 0.1' ON W. FACE OF POWER POLE, W.M. PER AS -BUILT 3 I o - - I s s'I.O3+00 S s s- ELEVATION = 411.79 FEET DRAWING #W -245 - ° n TBM 101 - EXISTING 50D NAIL UP 0.5' ON W. FACE OF POWER POLE, -r NE 2ND PLACE ELEVATION = 410.21 FEET EXISTING 36" (SPU) 3 w- W.M. APPROXIMATE _., w - - - - - ®w -EX 8 "D.L EX 8' "O.I_ LOCATION 263 - - - - - �II I p� -363 -L.F. 8 "0 PVC S.S. S.S.M.H. J4, TYPE 1 -48 "0 STA. - 193 16 4.39, -4,24' LT. THICKENED EDGE 103+54. 4. EXISTING 8 "0 D . W.M. APPROXIMATE SEE SHEET RD -01 100+65.76, 11.93' PER AS -BUILT DWG EX. S.S. STUB EXISTING HYDRANT STA. 449+66.87, 1153.90' RT. #W -505 LOCATIONS UPGRADE WITH STORTZ 1 -6" GATE VALVE (FLXMJ) S.S.M.H. #5, TYPE 1 -48" ADAPTOR IF EXISTING STORTZ ADAPTOR IS PER DETAIL 300.1 ON SHEET DT -06 STA 4 01+01 -68 25- LT. �0�00 NE 2ND PLACE NOT PRESENT 8 "X6" TAPPING TEE (MJXFL) 101+01.26, 3.57' 10 103+74.51, 12,32' STA. RT. STA 103 +73.35, 13.50' RT STA. 103+75.75, 13.45' RT 3 -8" GATE VALVES (FLXMJ) 1 -8" TEE (FL) SANITARY SIDE: SEWERS LOTS MIN. FF ELEV. SEWER STUB DEPTH 0 END OF STUB ELEV. 0 S.S. MAIN DOWNSTREAM S.S.M.H. 1 412.25 406.44 402.78 S.S.M.H. #5 2 410.25 404.17 400.53 S.S.M.H. #4 3 408.25 401.81 398.35 S.S.M.H. #4 4 406.25 399.08 395.93 S.S.M.H. 4 CONC. THRUST BLOCKING CUT -IN TEE CONNECTION PER DETAIL 300.4 ON SHEET DT -06 ! NOTES: . . aJ M r Q u7 M^ M r7 O cp M rn a N N W co O O O r,1 b sD o 10 Ion OD I� m m 1n a 1'9 ro a Oq 0 0 n aD 1. FILL AND COMPACT ROADWAY PRISM TO FINISH GRADE PRIOR rn 0 h vD� U1 d I") N OIL O� W Oj r c0 t7 to to o m o °' o o of LO 0' a' o M1 o N o rn o a, rn rn ED o, n (Do rn 0 on ui rn TO EXCAVATION FOR THE WATERMAIN INSTALLATION. O �F O y 0 ' O y. O ' O ' O d. O d. O M O M rn I+) M 01 a a s a a a Nj K3 M9 K9 n n I 2. ALL TRENCH RESTORATION SHALL BE PER THE CURRENT .___._ ..... - -_- - - - -- - _._.... __...- CITY OF RENTON TRENCH AND STREET OVERLAY DETAIL. - AS -BUILT CERTIFICATION: I HEREBY DECLARE TO THE BEST OF MY KNOWLEDGE 3. FOR SIDE SEWER CONNECTIONS SEE SIDE SEWER THAT THE INFORMATION SHOWN HEREON REFLECTS THE �p,N D /r CONNECTION DETAIL SHEET DT -04. SEWER STUBS TO THE "AS- CONSTRUCTED CONDITIONS." THIS CERTIFICATION PROPERTY LINE SHALL BE 6 -INCH MIN. 0 2% MIN. SLOPE. IS BASED UPON WORK PREPARED IN ACCORDANCE WITH - GENERAL CCEPTED PROFESSIONAL ENGINEERING �r - - - - ' -- 4. EXISTING MANHOLES AND MAIN TO BE ABANDONED OR AND /OR SU EYI PRAT E ,'$I is REMOVED, IN NE 2ND PLACE. CONTRACTOR MUST MAINTAIN SERVICE TO ALL EXISTING SEWER STUBS OFF EXISTING t-... 1959 SEWER MAIN. JONA7HM D. KARLE , L.S. NO. 41959 N4, yLAD .420 DAT . /�/�9/�/ 5. MAINTAIN WATER AND SEWER SERVICES TO EXISTING HOUSES. _...._._ ____ -_ - - -_- -- ._.. -- ____ _. -._ ._ -_..._ ._ --_ -- -___ -_ _ - - - -- -- __ - -_ -- - - - -- --- _ -.. ...- ... - ---.. ...--- -._ ..._. -- RECONNECT EXISTING SIDE SEWERS PER STD PLAN 407 ON _ 42_O__ PROPOSED SHEET DT -05. GRADE 0 � EXISTIN 410 G - - GRADE ' 41 J - -- - _ - - - - - - - - -- - -- -- - - -- - - -- - - - - - - -- - - -- - -- - PROPOSED O -- -- -- -- -- STORM DRAIN :26i 1 = w _ - I'I - -490 _ _ -r = _ - - - -- - _ - -- - -- - -- - - - - - - -- - - - - -- -- _._ _.... __ -- - -_ C S.S. 0 S ... - 3 L.F., 8 PV _ 400 S.S.M.H. E5 t STA. 1c1+01. 60, 2.25 T. RIM -;#99:48• - 409.60 I(N07 FlN{�L RIM GRAD EXISTING "0 D.I. W.M. ! `��° T� ' I.E. -4688- 6 "0 IN (N 402.43 I.E. - 4BP -i8- 8 "0 OUT E) 402.19 (ASSUMED ELEVATIONS) I " =" == "; (n 390 - - - -- - - `- - -- - -- - . __ _ -- - - - -- - - - _` _ - -- - - -- - - - -- -- - - -- 390 r ( I- W = z -- - ( EXISTING "0 SEWER = w S.S. 4 TYPE -48 "0 TO BE RE OVED OR U 3$� °8 380 __ -- -1 - -� - - - - -- -- - - -__. -i - - - - -- -� - -__ ..._._._ - - -- . - - - - -- - --- - - - - -I -1----- . _. - -- - STA. 1113 +64.39, 4: 1 T. 1 ! ABANDON F - C- - ----- -- --- - - - -- RIM = 396,66 38 .97 L`NOT FINAL RIM GRAQ� Q J -� ° ( I.E. = 1389-.89- 8 "0 IN (W N 38.48 w ( I.E. = 138'9.75';- 8 °0 bb?" 389.27 �a 100 +40 100 80 101 20 101 +60 1 102 F00 102 +40 102 +80 103--20 103 60 104 F00 o CHECKED FOR COMPLIANCE SECOND SUBMITTAL ESM ,/31/2 N WRR NOD „", D ' M0R60Nf��' 86 `' CITY OF GLADCO DEVELOPMENT, L.L.C. TO CITY STANDARDS 2 THIRD SUBMITTAL ESM w /22/201 1 �2C .9 DESIGNED: RO➢6DpI 3 FOURTH SUBMITTAL ESM 12/06/201 Rfx „u, ROSEWOOD HIGHLANDS GGLE: a 4 MYLARS ESM t2/22/201 RENTON 5 CONSTRUCTION SET ESM 02/24/2011 CHELNEO pON,E INCH_ � DATUM oRAMWIS Al ETO E INE I Planning /Building /Public works Dept. WATER AND SEWER PLAN AND PROFILE YIIS -02 ' Ce12 Working Days Before You Dig NOT ONE I x �N SGLLE MFGRGIHCLY 1 -800- 424 -5555 N0. REVISION BY DATE APPR rPxo D sx DE 18 31 u `= Vdbee Underground Location Center (IDWrWORWA) RENTON JOB NO. e REVISIONS NO. DESCRIPTION DATE BY 1 SECOND SUBMRIAL am 01/31/006 2 2 THIRD SUBMTOA am t 0/22/2010 3 FOURM SUBMRTAL FSM 12/06/2010 4 M M5 12/22/2010 ESM S DON6IRUCTWN SET 6M 02/24/2011 6 5 Buns 09/12/2011 ESM AS BUILT MTIARS am 10/19/2011 O 2 VJ 3 J zJ 0 O a 0- Z = o z cW G ((� V z a 0 = W W 0 N o O z z 0 U w � W~ 3 J 0 O z yO C U U Val ae �E N Q° Lu w ® a°L 0 0 C7 - 1u ° 00o E c Nm .2 0< c0 '�. °c g,3 E z$ J � 0) N O m' 0, Z Q J06 N9 N i v mmLL E o „ 3 `- o°0 =D �3 wD �a GEL L gT� T s�eA41L JOB NO: 1352-001-006 DWG. NAME: WS -02 DESIGNED BY: KIND DRAWN BY: CLC CHECKED BY: DATE: 10/19/2011 DATE OF PRINT: C pWS-02 1 V OF 31 SHEETS