HomeMy WebLinkAboutS-345906W *3,/4" SQUARES SPACED - 3/4" CONCRETE BLOCKING SIZING PROCEDURE NDICATED - HT. 1/8" CONCRETE A. GENERAL - Go to Table 2: Table 2 gives the safe bearir load for N y 5 CLASS 3000 THE AMOUNT OF CONCRETE REQUIRED TO ANCHOR HORIZONTAL BENDS, g 9 ° TEES, AND DEAD ENDS DEPENDS ON THE STRENGTH OF THE SOIL. THE sand and gravel: 3,000 lbs. /sq. ft. N .: - Go to figure 1: figure 1 indicates the position s o A 1 0 METHODS OF PLACING CONCRETE TO KEEP THE JOINT ACCESSIBLE IS 1/2° SHOWN IN FIGURE 1. THE AREA IN SQUARE FEET OF CONCRETE WHICH of the concrete for blocking the 90' bend "'- MUST BEAR AGAINST THE SIDE OF THE TRENCH IS FOUND BY DMDING - Go to the specifications of the project and find ° - THE THRUST IN POUNDS SHOWN IN TABLE t BY THE S4fE BFARING LOAD depth of trench (h) = 4 feet � � c,i � 4-3/4" OF THE SOIL AS SHOWN IN TABLE 2. -Width of trench (W) = 3 feet IW- Oz ¢ 12 "0 8. CRITERWith the above assembled information, z 1 -x 1. THE SIZING PROCEDURE IS FOR HORIZONTAL OR DOWNWARD WO c COVER TO READ °SEWER° THRUST ONLY. we proceed to the final calculations: IN RAISED LETTERS RAISE -1/2 FIBER JOINT PACKING 2. HEIGHT OF THE THRUST BLOCK MUST BE EQUAL TO OR LESS p O N GO NOTES. WIDE BORDER THAN 1 2 THE DEPTH FROM THE GROUND SURFACE TO THE BLOCK Thrust 21 60_ O F -C C.D / -Area of Concrete (A) _ _ 000 7.12 sq ft. BASE Safe Bearing Load 3,000 1. IN UNIMPROVED AREAS POUR 1' -0° THICK 2' -0° SQUARE 3. THE THRUST BLOCK BEARING FACE IS APPROXIMATELY on z 1"- O CONCRETE, CLASS 3000, PAD AROUND RING AND COVER. 10" RECTANGULAR. Depth of Trench in Feet 4. THE CONCRETE BLOCKING SHALL BE AS PER APWA _ 2 O an o PIPE MATERIAL =PVC SDR 35 45' (1 /8) BEND - Maximum Height of Thrust Block Hm z z 0 2. IN ASPHALT ROADWAYS RESTORE AROUND CLEANOUr RING g" SPECIFICATION 74 -2.14. 9 ( ) _� =-4= 2.0 ft. O AND COVER AS REQUIRED BY STANDARD DETAIL DRAWING BR36. C. SYMBOLS 2 D = OUTSIDE DIAMETER OF PIPE IN FEET - T = THRUST IN POUNDS AT THE FfRTNG (TABLE 1) - Depth of Concrete Thrust Block (Dc) 1 -1/4'• 1/2' 2" 5J8" SBL = SAFE BEARING LOAD IN POUNDS /SQ. FT. (TABLE 2) 88 r� H = DEPTH OF TRENCH IN FEET _Width of Trench in Feet (W) - Outside Diameter of Pipe (d) Z 3 2 -7 8' 4' m A =AREA OFFCONRCEtE WHICH MUST BEAR AGAINST = 3 - 0'2 = 1.13 ft. 2 W Amo of Concrete WQ a 7 `a - Maximum Length of Thrust Block (Lm) -Height of Concrete S THE SIDE OF THE TRENCH IN SQ. FT. y ,,,;,c HM = MAXIMUM HEIGHT OF THE THRUST BLOCK IN FEET =A-=! .2 _ 3.56 ft. p DC = DEPTH OF THE CONCRETE THRUST BLOCK TO Hm 2.0 BEARING SURFACE IN FEET 7 -3 4 - - Required Amount of Concrete = (Height x Depth x Length) x 0.03704 UA = MAXIMUM LENGTH OF THE THRUST BLOCK IN FEET _ (Hm x Lm x Dc) x 0.03704 B II PLUG TO BE SEALED (( O ; --� -T- IN SAME MANNER AS = 3 Y 0 cu. 56d z 1.13) x 0.03704 Z N 15" - - _ _ MAIN SEWER JOINTS. ,,,,,1 NTS a' CAST IRON RING AND COVER Sudary Sewer Cleanout b GROUND SURFACE TABLE 1 S 2� V = TOP ELEVATION= SEE TABLE OIL /WATER SEPARATOR NOTE h d • `o HOLD -DOWN "? THE OIL WATER SEPARATOR SHALL BE UTILITY VAULT 577 CPS APPROVED EQUAL Hm h m o ° FOR COALESCING MEDN o.- WITH THE FOLLOWING SPECIFICATIONS: 2 ' wz 9 _ �'E DESIGN FLOW 0.363 CFS BLOCK BASE \� 3 a RISERS PROJECTED PLATE AREA 590 SQ FT Dc (SEE TABLE) DESIGN TEMPERATURE 39' F W SPECIFIC GRAVITY OF OIL 85 gm /cc ►-ti W a a o o MINIMUM OIL PARTICLE SIZE REMOVED 60 MICRONS c 6° INLET _ _ _ _ o / o _ Q 6° OUTLET DO NOT PAVE OR GO UNTIL AFTER SEPARATOR MODULE HAS BEEN INSTALLED. D. CALCULATION EQUATION IE= (SEE TABLE) = IE= (SEE TABLE) FILL WITH CLEAN WATER PRIOR TO START UP. 1. Area of Concrete (A) = Thrust In Pounds =1 Size Pressure PSI Thrust at Fittings in Pounds Tees 90' 45' 22 -1/2" 11 -1/4° INLET IE 29.72 Dead Ends Bend'. Bend Bend Bend 3° 300 2,120 31000 1,630 830 430 4° 300 3,780 5,370 2,910 1,470 750 6° 300 8,500 12,001) 6,510 3,320 1,700 8" 300 15,100 21,360 11,550 5,880 3,020 10" 275 21,620 30,570 16,540 8,430 4,330 12" 250 33,930 48,000 25,950 13,260 6,780 14° 250 46,200 65,370 35,340 18,030 9,240 16" 225 45,250 64,0 0 34,620 17,650 9,050 18" 200 50,900 72,0gqO 38,940 19,860 10,180 20" 200 62,840 88,900 48,080 24,520 12,560 24° 200 90,480 127,9j30 69,200 35,320 18,100 30" 200 141,370 199,9130 108,150 55,140 28,280 36° 200 203,580 287,950 155,740 79,400 40,720 j Safe Bearing Load In Pounds / SBL 7C - OUTLET PIPE NOTE: WITH SAMPLING TEE OIL WATER SEPARATOR SHALL BE UTLIIY VAULT 577 CPS COALESCING PLATE STORM 2. Maximum Height of Thrust Block (Hm) = Depth of Trench in Feet -h TABLE 2 WATER SEPARATOR MODEL 577 -SA OR APPROVED EQUAL INLET PIPE BY OTHERS 2 2 TSaafe Bearing Loads iinn Lb. /Sa. Fth f II t 61 f o m WITH SAMPLING TEE 'J (Width of Trench in Feet) - e s e eanng oa s given In e o owing o e are or (Outside Diameter of Pipe in Feet) horizontal thrusts when the depth of cover over the pipe 3. Depth of Concrete Thrust Black = 2 2 exceeds 2 feet. 4. Maximum Length of Thrust Block (Lm) = Area of Concrete = A SOIL �e per Siii. Load Maximum Height Hm •Muck, peat, etc. 0� f 5. Required Amount of Concrete (Cu. Yd.)= (Height x Depth )x Length) x 0.03704 Sa dCI% 2,000 = Hm x Lm z Dc x 0.03704 Sand and Gravel 3,000 E. EXAMPLE Sand and Gravel Cemented with Clay 4,000 1. Proe Hard Shale 10;000 : Calculation of the amount of concrete required to block a 90' bend in an 8° ' • , VAULT p C.I. water main; the normal operating pressure in the pipe will be 65 psi *In muck or peat, all thrusts shall be restrained: by piles or 577-CPS and the soil condition in the area indicates sand and gravel. tie rods to solid foundations or by removal of amuck wa z 6 SEDIMENT WEIR-/ �- -COALESCING MEDIA qL RETAININ4 -1/2° NTS or peat and replacement with ballast of sufficient BAFFLE Sand 1 Oil Separator - 2' '�' stability to resist thrusts. Maximum testing pressure (See Table 1) = 300 psi. - Outside diameter of 8° pipe = 9.05 in. = 9.05/12 - Go to Table 1: The testing pressure of 300 psi, we see a that the thrust on a 90' bend is 21,360 pounds. s a 8 °x8° VERTICAL CROSSING (WxFL) ((1)) 8" BLIND FLANGE a (1) 8° BLIND FLANGE W/ 2° TAP & 2° PLUG \ o. 1 8° PLUG (MJ) W/ 2" TAP & BLOW OFF 11 -1/4' a W/ TEMP BLOCKING 90' BEND w REMOVE CLEANING 'POLY-PIG" CAP a 0 22 -1/2' FIGURE 1 '.. EXISTING 12" DI WATER EXISTING 12° DI WATER M NOTE: FOR CONVEX VERTICAL BENDS BLOCKING .�{ tp• It- SEE APWA STANDARD PLAN NO. 73. �A �e 4 AFTER ALL TESTING, CLEANING, 1 12 °x8° TEE (FLxFL) S AND DISINFECTING REMOVE TEMP 2 12° GATE VALVES (FLxMJ) �.�6 ",>3'�`'�•a�' BLOCKING & BLOW OFF AND CONNECT 1 8° GATE VALVE (FLxMJ) WITH 8" SLEEVE (MJ) & 8° SPOOL 2 12° SLEEVES (MJ) zo 2 8° SPOOLS (MJ)�Q N FPJAL WTI DEAL TESTM DUAL 1 8° PLUG (MJ 45' BEND W/ 2" TAP & TEMP BLOW OFF TEE `+ W/ THRUST BLOCKING NITS �/� DETAL A Concrete Blocking Sizing Procedure L ,�tir� C. Ao Renton School District SHEET COUGHLIN PORTERL EE 444 w°fw�s �� Transportation Center A CONSULTING STRUCTURAL AND CIVIL ENGINEERING CORPORATION y er a" °® IFMZO 413 STREET A 981 SUITE 300 P: 206/343 -5691 A�8 '�'Y (015 1NTS SEATTLE, WA 98101 F: 206/343 -5691 0 °v@g$T /�Q° „/ � 1 Water Testing and Correction Detail 1® sIONAL 1islio DE'T STORMWATER 0/W SEP BUS WASH 0/W SEP SERVICE BLDG 01W SEP TOP EL 34.85 37.27 35.90. INLET IE 29.72 28.64 30.27 OUTLET IE 29.72 28.64 30.27 RISERS (1) 12° (1) 18° (3) 24° (1) 12" (1) 24° (Width of Trench in Feet) - e s e eanng oa s given In e o owing o e are or (Outside Diameter of Pipe in Feet) horizontal thrusts when the depth of cover over the pipe 3. Depth of Concrete Thrust Black = 2 2 exceeds 2 feet. 4. Maximum Length of Thrust Block (Lm) = Area of Concrete = A SOIL �e per Siii. Load Maximum Height Hm •Muck, peat, etc. 0� f 5. Required Amount of Concrete (Cu. Yd.)= (Height x Depth )x Length) x 0.03704 Sa dCI% 2,000 = Hm x Lm z Dc x 0.03704 Sand and Gravel 3,000 E. EXAMPLE Sand and Gravel Cemented with Clay 4,000 1. Proe Hard Shale 10;000 : Calculation of the amount of concrete required to block a 90' bend in an 8° ' • , VAULT p C.I. water main; the normal operating pressure in the pipe will be 65 psi *In muck or peat, all thrusts shall be restrained: by piles or 577-CPS and the soil condition in the area indicates sand and gravel. tie rods to solid foundations or by removal of amuck wa z 6 SEDIMENT WEIR-/ �- -COALESCING MEDIA qL RETAININ4 -1/2° NTS or peat and replacement with ballast of sufficient BAFFLE Sand 1 Oil Separator - 2' '�' stability to resist thrusts. Maximum testing pressure (See Table 1) = 300 psi. - Outside diameter of 8° pipe = 9.05 in. = 9.05/12 - Go to Table 1: The testing pressure of 300 psi, we see a that the thrust on a 90' bend is 21,360 pounds. s a 8 °x8° VERTICAL CROSSING (WxFL) ((1)) 8" BLIND FLANGE a (1) 8° BLIND FLANGE W/ 2° TAP & 2° PLUG \ o. 1 8° PLUG (MJ) W/ 2" TAP & BLOW OFF 11 -1/4' a W/ TEMP BLOCKING 90' BEND w REMOVE CLEANING 'POLY-PIG" CAP a 0 22 -1/2' FIGURE 1 '.. EXISTING 12" DI WATER EXISTING 12° DI WATER M NOTE: FOR CONVEX VERTICAL BENDS BLOCKING .�{ tp• It- SEE APWA STANDARD PLAN NO. 73. �A �e 4 AFTER ALL TESTING, CLEANING, 1 12 °x8° TEE (FLxFL) S AND DISINFECTING REMOVE TEMP 2 12° GATE VALVES (FLxMJ) �.�6 ",>3'�`'�•a�' BLOCKING & BLOW OFF AND CONNECT 1 8° GATE VALVE (FLxMJ) WITH 8" SLEEVE (MJ) & 8° SPOOL 2 12° SLEEVES (MJ) zo 2 8° SPOOLS (MJ)�Q N FPJAL WTI DEAL TESTM DUAL 1 8° PLUG (MJ 45' BEND W/ 2" TAP & TEMP BLOW OFF TEE `+ W/ THRUST BLOCKING NITS �/� DETAL A Concrete Blocking Sizing Procedure L ,�tir� C. Ao Renton School District SHEET COUGHLIN PORTERL EE 444 w°fw�s �� Transportation Center A CONSULTING STRUCTURAL AND CIVIL ENGINEERING CORPORATION y er a" °® IFMZO 413 STREET A 981 SUITE 300 P: 206/343 -5691 A�8 '�'Y (015 1NTS SEATTLE, WA 98101 F: 206/343 -5691 0 °v@g$T /�Q° „/ � 1 Water Testing and Correction Detail 1® sIONAL 1islio DE'T