Loading...
HomeMy WebLinkAboutS-347326PLANE EX HMA 2" DEPTH /KEEPING EXISTING GRADE. PLACE NEW 2" THICK ASPHALT OVERLAY THICK @ 0 HMA (CLASS YZ') �j—MATCH EX. SLOPE (1) ROADWAY CROSS SECTION 2F) NTS HMA (CLASS Y2 ") MATCH EX, SLOPE, t I-2" THICK 0 0 48' MIN. UNLESS OTHERMSE APPROVED BY THE ENGINEER PVC PIPE 6 "MIN. T_ -COPPER TRACE WIRE ATTACHED TO PIPE w/ DUCT TAPE MATERIALS NOTE: REFERENCE RENTON STD. PLANS 110.1 AND 405 FOR FURTHER DETAIL. TRENCH DETAIL FOR FORCE MAIN NTS 2" HMA (CLASS 1 ") OVERLAY PER TYP, ROADWAY CROSS SECTION MIN. 2" HMA (CLASS 11 ") MATCH EX. PAVEMENT DEPTH 6" CRUSHED SURFACING TOP COURSE, COMPACT TO 95% MODIFIED PROCTOR EX. PAVEMENT \� \� \/ \// / UNDSTURBED ROADWAY CROSS SECTION /'`E `SAW CUT EDGE OF EX. PAVEMENT COURSE OR NATIVE 1IR 3 "x3 %3/8" ANGLE IRON CUT 2" HMA CLASS 74 ") OVERLAY PER ( TO FIT W/ 1 1/2' HOLE THR*TE ") PLANE Ex HMA 2" DEPTH TYP. ROADWAY CROSS SECTION TOP CENTER, TYPICAL WELDE HMA (CLASS Ys KEEPING EXISTING GRADE. MIN. 2" HMA (CLASS & ") MATCH TO GATE MATCH EX. SLOPE 2" THICK PLACE NEW 2" THICK EX, PAVEMENT DEPTH GGATE ASPHALT OVERLAY 6" CRUSHED SURFACING TOP COURSE, COMPACT TO 95% MODIFIED PROCTOR INSTALL 4 RED REFLECTORS i 0 x 4" LONG 1' EX. PAVEMENT W/ 1/4" PIN GALV STEEL. PLATES "WFROM2 1/2" HOLE MIN. WELDED OR BOLTED TO GATE 3 /8 BARS. REFLECTORS TO FACE VARIES i5 if 0 oa oOO o0 000° oo 0 00 00 0 0o %��� VEHICLE ENTRANCE SIDE ONLY - —_\ o�° o00 PA y\ <1 \ \ \ \ //\ \ /j\ A� CONCRETE CAP FUR3 "N SCH 40 STEEL PIPE. TOP / /�\�� SAW CUT EDGE "0 BY OF GATE TO BE LEVE L " "" / \ \ / ��A /�� OF EX. PAVEMENT J:. 6 SCH BO 21 -0 �1 ROADWAY CROSS SECTION �o�RSEGR °NATVE BA TOP STEEL POST UNDISTURBED 3' -0 "' 3' -0' 3' -0' 26 NT$ NATIVE j IF APPROVED IN WRITING BY MATERIAL ` i0 95% MODIf ED PROCTORT n PLANE EX HMA 2" DEPTH /KEEPING EXISTING GRADE. PLACE NEW 2" THICK ASPHALT OVERLAY THICK @ 0 HMA (CLASS YZ') �j—MATCH EX. SLOPE (1) ROADWAY CROSS SECTION 2F) NTS HMA (CLASS Y2 ") MATCH EX, SLOPE, t I-2" THICK 0 0 48' MIN. UNLESS OTHERMSE APPROVED BY THE ENGINEER PVC PIPE 6 "MIN. T_ -COPPER TRACE WIRE ATTACHED TO PIPE w/ DUCT TAPE MATERIALS NOTE: REFERENCE RENTON STD. PLANS 110.1 AND 405 FOR FURTHER DETAIL. TRENCH DETAIL FOR FORCE MAIN NTS 2" HMA (CLASS 1 ") OVERLAY PER TYP, ROADWAY CROSS SECTION MIN. 2" HMA (CLASS 11 ") MATCH EX. PAVEMENT DEPTH 6" CRUSHED SURFACING TOP COURSE, COMPACT TO 95% MODIFIED PROCTOR EX. PAVEMENT \� \� \/ \// / UNDSTURBED ROADWAY CROSS SECTION /'`E `SAW CUT EDGE OF EX. PAVEMENT COURSE OR NATIVE 1IR NTS NATIVE /E MATERIAL ,�ENGINEER, APPROVED IN WRITING BY COMPACT TO 95% MODIFIED PROCTOR PLANE EXISTING HMA HMA (CLASS YZ') SEAL JOINT WITH BINDER PG 64 -22 EX. HMA VARIES 2" (TYPICALLY 2" — 4 ") 10' �I EXISTING HMA PAVEMENT — 3 NOTES: > 1. SEE PLANS FOR SPECIFIC CONSTRUCTION ° I LOCATIONS 2. MATCH JOINTS SHALL BE CONSTRUCTED IN n ACCORDANCE WITH SECTION 5- 04.3(21) (ASPHALT CONCRETE PAVEMENT BUTT JOINTS). s 3. PLANING SHALL BE DONE IN ACCORDANCE WITH SECTION 5- 04.3(14) (PLANING - BITUMINOUS PAVEMENT). BUTT JOINT DETAIL NTS i iI0 HUT I -'rlI LL Roth Hill, LLC Tel 425.869.9448 www.rothhill.com 11130 NE 33rd Place, Suite 200 Bellevue, WA 98004 PVC PIPE fi'MIN. T_ BEDDING MATERIALS (-�-- 38 "MIN. NOTE: REFERENCE RENTON STD. PLANS 110.1 AND 405 FOR FURTHER DETAIL, TRENCH DETAIL FOR GRAVITY MAIN NITS STAINLESS STEEL CASING SPACER (CASCADE WATERWORKS MFG.) OR EQUAL S12ED TO FIT CARRIER PIPE & CASING WITH SAND AR SPACE 6 "0 SCH 80 STEEL POST FILLED W/ CONIC, TYP EACH SIDE'S 3 "0 SCH 40 STEEL PIPE WELDED STEEL HINGE FIXTURES W/ BOLT THRU CENTER, THREE (3) EACH NEW PRECAST MANHOLE BASE SECTION 24 "TYP �_6 %6 %3/8" 3' "I MIN GALVANIZED STEEL GUSSET EXISTING ROAD SURFACE SUPPORTS 3' -2" NOTES GATE & POST CONSTRUCTION SHALL CONSIST OF HOT DIPPED GALVANIZED STEEL PIPE. ALL CROSSBARS SHALL HAVE CONTINUOUS FILLET WELD. CONTRACTOR SHALL FIELD VERIFY DIMENSIONS & PROVIDE SHOP DRAWINGS OF GATE & POST ASSEMBLY (INCLUDING HINGE & LATCH FIXTURES) FOR APPROVAL BY CITY REPRESENTATIVE PRIOR TO CONSTRUCTION. ALL METAL & WELD JOINTS ASSOCIATED W/ GATE & POST ASSEMBLY SHALL BE HOT DIPPED GALVANIZED STEEL & GALVANIZED STICK TREATMENTS FOR JOINTS. ACCESS GATE DETAIL NTS i I+--- NEW PRECAST MANHOLE SECTION ( 24 "TYP 10° HOPE -1 SEWER MAIN COUPLING (TYP) - -1TI -I Iil- III -Tt F n EE T X. 8" SEWER MAIN 10 "SDR 35 - -8 "SDR 35 PVC SPOOL PVC SPOOL 4 "- 6" COMPACTED CONCRETE OR SAND COLLAR MIT BEDDING MATERIAL ADAPTER FOR PVC PIPE (TYP) ELEVATION INSTALLATION PROCEDURES: 1. EXPOSE & REMOVE EXISTING PIPE. 2, SET MANHOLE & PVC SPOOL PIECES IN PLACE TO PROPER ALIGNMENT & GRADE 3. RECONNECT PIPE WITH COUPLINGS ( ROMAC 501 LONG BARREL OR EQUAL) COUPLINGS SHALL HAVE ROMAC S.S. STIFFENING INSERT OR EQUAL FOR HOPE PIPE END. ............ 4. CHANNEL MANHOLE PER CITY STANDARDS. 18 "MIN. (PER PLANS, STEEL OR CASING SEAL -'� I-8 'PVC FORCE MAIN HOPE CASING TO FIT CARRIER (TYREACH PIPE. NDTES END) 1. FILL ANNULAR SPACE BETWEEN SEWER FORCE MAIN AND STEEL SECTION A -A CASING WITH SAND. 2, SEAL EACH ENDS OF CASING WITH FLEXIBLE END SEALS SUCH AS MODEL W BY PIPELINE SEAL & INSULATOR OR EQUAL. 3- CASING SPACERS SHALL BE INSTALLED A MAXIMUM OF 10' ON CENTER. PIPE CASING DETAIL SPECIAL MANHOLE CUT -IN INSTALLATION NTS CLD , :5" 3 '�-?i.we� r; 18 "0 CONCRETE I'„ FOOTING, TYP—, i 18 "0 CONCRETE I'„ FOOTING, TYP—,