Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutS-347346DOOR SCHEDULE
DOOR
FRAME
ASSEMBLY
REMARK S
N0.
SIZE
WIDTH x HEIGHT
TYPE
MAT.
MAT.
DETAILS (SEE NOTE 1 BELOW)
HARDWARE GR
FIRE
RATING
FINISH
HEAD
JAMB
SILL
1
PAIR 3' -2" x 8' -4"
A
H.M.
H.M.
1
2
3
1
-
DOOR INSULATION FACTOR: DOORS SHALL HAVE A U
VALUE OF 0.6 OR LOWER
ALLOWED
CONTROL
CMU
PRESSURE TREATED
1
15,500
4
1
BUILDING
F -1
NONE
NO
V -B
15
1
DOOR TYPES DOOR NOTES
II /I\ II 1. DOOR DETAILS ARE ON SHEET A3 UNLESS OTHERWISE NOTED.
9
DOOR ABBREVIATIONS
HM = HOLLOW METAL
FINISH SCHEDULE
ROOM
FLOOR
BASE
WALL
CEILING
CEILING
HEIGHT
REMARKS
N0.
NAME OF
ROOM OR SPACE
MATERIAL
FINISH
MATERIAL
FINISH
101
CONTROL BUILDING
CONCRETE
CONCRETE
GYPSUM BOARD
©
GYPSUM BOARD
©
VARIES
SEP.
�I�IFDl7 ■�Nll
PAINT SYSTEMS: SEE SPECIFICATIONS SECTION 10.09900 FOR PAINTING SYSTEMS INDICATED IN THE SCHEDULE
SYSTEM A = GLOSS FINISH
SYSTEM B = SEMI -GLOSS FINISH
SYSTEM C = EGGSHELL FINISH
`o I 1. PAINT ALL HOLLOW METAL DOORS AND FRAMES PAINT SYSTEM
� I 2. PAINT ALL EXPOSED EXTERIOR AND INTERIOR STEEL PAINT SYSTEM (D INCLUDING
• METAL FABRICATIONS
° • SHEET METAL FLASHINGS THAT ARE NOT FACTORY FINISHED
d
u • ROOF ACCESSORIES THAT ARE NOT FACTORY FINISHED.
D
'I
3. ALL EXPOSED INTERIOR & EXTERIOR CMU AND CONCRETE SHALL HAVE CLEAR WATER RESISTANT SEALER,
SEE SPECIFICATION 10.07190.
4. SEE DRAWING A2 FOR CMU AND ROOF COLORS.
I
Roth Hill, LLC Tel 425.869.9448 www.rothhill.com
11130 NE 33rd Plaoe, Suite 200 Bellevue, WA 98004
Kennedy /Jenks Consultants
32001 32nd Avenue South, Suite 100
Federal Way, WA 96001
Ph. 253 - 835-6400
Fax 253 - 952-3435
0
io
DOWNSPOUT
LINE OF ROOF
OVERHANG
ABOVE --�'
RIM
CMU SCREEN WALL, SPLIT -FACE FINISH BOTH SIDES
3' -0 MIN. CLEAR
0
w
1 INCH R-7 RIGI)i
ROOF INSULATION
• BATT ROOF
INSULATION
GENERATOR ENCLOSURE
20' -0"
FIRE
ACOUSTIC LOUVER,
2' -0" x 2' -0"
CONTROL BUILDING
0,
CONC. PAD
ACOUSTIC LOUVER,
2' -0" x 2' -0 "-
PLAN
SCALE: 1/4"=l'-O"
PREFINISHED METAL
ROOF
O
2' -0" TYP @ EAVES
J
pz
z�a
w
Q W -i
W ' o
wo
0
I
r
z
0
OZ
�w 0
Vi=a N
100
0
DOWNSPOUT
-0"
CODE SYNOPSIS BASED ON
THE 2006 IBC
1P \�—
BUILDING USE
CONSTRUCTION
OCCUPANCY
C
ACTUAL HEIGHT
AREA
FIRE
ID N0.
NAME
TYPE
SPRINKLE
TYPE
SEP.
ADA
FEET
TORIE
ACTUAL SO. FT.
ALLOWED
CONTROL
CMU
PRESSURE TREATED
1
15,500
4
1
BUILDING
F -1
NONE
NO
V -B
15
1
240
SF
PER
NO
A3 GENERATOR
NOTES
PANELS
OPP ENCLOSURE
FLOOR
I
Roth Hill, LLC Tel 425.869.9448 www.rothhill.com
11130 NE 33rd Plaoe, Suite 200 Bellevue, WA 98004
Kennedy /Jenks Consultants
32001 32nd Avenue South, Suite 100
Federal Way, WA 96001
Ph. 253 - 835-6400
Fax 253 - 952-3435
0
io
DOWNSPOUT
LINE OF ROOF
OVERHANG
ABOVE --�'
RIM
CMU SCREEN WALL, SPLIT -FACE FINISH BOTH SIDES
3' -0 MIN. CLEAR
0
w
1 INCH R-7 RIGI)i
ROOF INSULATION
• BATT ROOF
INSULATION
GENERATOR ENCLOSURE
20' -0"
FIRE
ACOUSTIC LOUVER,
2' -0" x 2' -0"
CONTROL BUILDING
0,
CONC. PAD
ACOUSTIC LOUVER,
2' -0" x 2' -0 "-
PLAN
SCALE: 1/4"=l'-O"
PREFINISHED METAL
ROOF
O
2' -0" TYP @ EAVES
J
pz
z�a
w
Q W -i
W ' o
wo
0
I
r
z
0
OZ
�w 0
Vi=a N
100
0
DOWNSPOUT
-0"
98t5- 34-7317
1P \�—
TRUSS, SEE
/ \
BOARD
C
DWGS
ACOUSTIC
SPLIT FACE
LOUVER
`\
CMU
PRESSURE TREATED
1
2x3 WOOD STUDS
4
® 16" O.C.
ELECTRICAL
A3 GENERATOR
NOTES
PANELS
OPP ENCLOSURE
I i
HAND
1. ALL DIMENSIONS ARE TO
FACE
OF CMU UNLESS NOTED OTHERWISE
I i
6" HIGH x 12"
WIDE STARTER
CURB
_W
T.O. SLAB
R -10 RIGID SEE STRUCUTRAL
_
6 � �
FOUNDATION DRAWINGS FOR
GENERATOR PAD
INSULATION
LEGEND
A3
SECTION
A
O DOOR IDENTIFICATION
TAG,
SEE DOOR SCHEDULE
SCALE: 1/4 " =1' -0"
-
FTO-1-1 ROOM IDENTIFICATION
TAG,
SEE FINISH SCHEDULE
7417
V�REG�ISTERET D
CMU WALL
IT
1
RECORD DRAWING
These Record Drawings have been prepared based on informalion provided
48" 36" 24" 12" 0 2' N 6' 8'
by the contractor and others. Kennedy /Jenus Consultants has not verified the
DANIEL J. WRIGHT
oci. nim. �iri iiiii_ i ✓icii -a,
accuracy or completeness of infonna6on provided to them and does net
warrant the accuracy or completeness of these Record Drawings. Users of
ISTATE OF WASHINGTON
SCALE: 1/4 " =1' -0"
these Record Drawings assume all risk of bas resulting from their uee.
98t5- 34-7317