HomeMy WebLinkAboutS-347349HVAC /PLUMBING LEGEND 24x12 S 24x12 DUCT — FIRST FIGURE IS SIDE SHOWN 12x12 12x12 - DUCT WITH ACOUSTICAL LINING DIMENSIONS ARE FREE i DIRECTION OF FLOW SUPPLY DUCT — ELBOW UP OR DOWN � )NET AREA ARROW DINRDIRETR IIONR DROP FD), BELT DRIVE STANDARD BRANCH WITH SPUTTER DAMPER NOTES BFP BACKFLOW PREVENTER GPM RETURN DUCT — ELBOW UP OR DOWN BR BOILER 650 0.25 s' BTU BRITISH THERMAL UNIT MANUAL VOLUME DAMPER ( 'i�'I JJJ- -- Lij �/ STANDARD BRANCH WITH SPUTTER DAMPER AND TURNING VANES ---D —i BD BACK DRAFT DAMPER i� FD FIRE DAMPER (PROVIDE ACCESS DOOR FOR INSPECTION AND LINK REPLACEMENT.) T t _ ED' � ED GRILLE AND REGISTER CONNECTION WITH EXTRACTION DAMPER BCD CONTROL DAMPER AD '�� AD[j ' AD DUCT ACCESS DOOR CENTRIFUGAL HS HAND SWITCH CER FC FLEXIBLE DUCT CONNECTION `—�12x1 ,, Ml2x122 SC p 0�— (W SC ID 00 CEILING SUPPLY DIFFUSER INDICATING NECK SIZE, THROW, & AIR QUANTITY ® SUPPLY DUCT IN SECTION z EXHAUST OR RETURN DUCT IN SECTION ��I�12x12p 12x17,2 CER 200 EC R 00 CEILING EXHAUST OR RETURN REGISTER INDICATING NECK SIZE, THROW, & AIR QUANTITY OT THERMOSTAT CHILLED WATER SUPPLY 2 12x120 WSD2p 1217200 WSDp WALL SUPPLY DIFFUSER INDICATING NECK SIZE, THROW, & AIR QUANTITY O TEMPERATURE SENSOR IIOII 1220012 200 WER ����-- --IIIIIIII WEIR WALL EXHAUST OR RETURN REGISTER INDICATING NECK SIZE, THROW, &AIR QUANTITY HS HAND SWITCH CSD CEILING SUPPLY DIFFUSER IN. FLOW METER 5� I 1 COEFFICIENT, VALVE FLOW TURNING DUCT � WATER HEATER —N HB HOSE BIBB OI INTERLOCK LAVATORY GATE VALVE OM MOTOR POUNDS IOI LOSS IN FEET BALL VALVE LEAVING WATER TEMPERATURE HVAC AND PLUMBING ABBREVIATIONS ;I AC AIR CONDITIONING F FAN AH AIR HANDLING UNIT FC FAN COIL TYPE DRIVE FD FLOOR DRAIN BD BELT DRIVE VOLTS /PHASE NOTES BFP BACKFLOW PREVENTER GPM GALLONS PER MINUTE BR BOILER 650 0.25 s' BTU BRITISH THERMAL UNIT H HEATING i BUILDING HC HEATING COIL - CC COOLING COIL HOA HAND /OFF /AUTO CD CONTORL DAMPER HP HORSEPOWER CENT CENTRIFUGAL HS HAND SWITCH CER CEILING EXHAUST RETURN HSPF HEATING SEASONAL PROFICIENCY FACTOR CFM CUBIC FEET PER MINUTE HTG HEATING CH CHILLER HVAC HEATING VENTILATING AIR CONDITIONING '- CHWS CHILLED WATER SUPPLY HWR HEATING WATER RETURN 1 CHWR CHILLED WATER RETURN HWS HEATING WATER SUPPLY CO CLEAN OUT CSD CEILING SUPPLY DIFFUSER IN. INCHES CV COEFFICIENT, VALVE FLOW L LOUVER D DRAIN LAV LAVATORY > DB DRY BULB LBS POUNDS DH LOSS IN FEET LWT LEAVING WATER TEMPERATURE EER ENERGY EFFICIENCY RATIO MBH BTU PER HOUR (THOUSANDS) > EF EXHAUST FAN MFGR. MANUFACTURER ESP EXTERNAL STATIC PRESSURE EWT ENTERING WATER TEMPERATURE ELECTRICAL INSTALLATION BY THE ELECTRICAL CONTRACTOR IS LIMITED TO THE CONDUIT AND WIRE NECESSARY TO PROVIDE POWER TO THE UNITS. THE CONTRACTOR SHALL PROVIDE AND INSTALL ALL NECESSARY CONDUIT, WIRING, CONTROLS AND APPURTENANCES FOR A COMPLETE AND OPERABLE HVAC SYSTEM. 2. ALL SPACE CONDITIONING EQUIPMENT SHALL MEET THE REQUIREMENTS OF THE WASHINGTON STATE ENERGY CODE AND SECTION 10.15800. 3. PROVIDE PLUMBING AND DRAIN PIPING IN ACCORDANCE WITH SECTION 10.15400. PROVIDE SERVICE CONNECTION AND METER IN ACCORDANCE WITH KING COUNTY WATER DISTRICT NO. 90 STANDARD DETAILS. SEE CIVIL DRAWINGS FOR LOCATION. PHILL Roth Hill, LLC Te1425.869.9448 www.rothhill.com 11130 NE 33rd Place, Suite 200 Bellevue, WA 98004 FAN SCHEDULE TAG NO. LOCATION AREA SERVED TYPE DRIVE RPM CFM ESP (IN. W.C.) HP VOLTS /PHASE NOTES EF -1 CONTROL BUILDING CONTROL SIDEWALL DIRECT 1550 650 0.25 1/8 120/1 1,2,3 2 208/1 BUILDING EXHAUST BUILDING PRESSURE NOTES: 1. PROVIDE BACK DRAFT DAMPER. 2. ALL ONE —PHASE FRACTIONAL HP MOTORS TO BE FURNISHED WITH FACTORY — MOUNTED DISCONNECT SWITCHES. 3. THERMOSTAT — CONTROLLED. ELECTRIC HEATER SCHEDULE SCHEDULE TAG NO. LOCATION AREA SERVED TYPE AIRFLOW (CFM) kW VOLTS/ PHASE NOTES LOCATION SERVED EXHAUST (CFM) (IN) (IN) PHASE CD -1 EH -1 CONTROL BUILDING CONTROL BUILDING UNIT 700 2 208/1 1 NOTES: 1. REMOTE THERMOSTAT CONTROLLED. CONTROL DAMPER SCHEDULE SCHEDULE TAG NO. LOUVER INTAKE/ AIRFLOW WIDTH HEIGHT VOLTS/ TAG NO. LOCATION SERVED EXHAUST (CFM) (IN) (IN) PHASE CD -1 CONTROL BUILDING L -1 INTAKE 650 24 24 120/1 LOUVER SCHEDULE TAG NO. LOCATION AREA SERVED INTAKE/ EXHAUST AIRFLOW (CFM) WIDTH (IN) HEIGHT (IN) TYPE L -1 CONTROL BUILDING CONTROL BUILDING INTAKE 650 24 24 6" ACOUSTIC L -2 CONTROL BUILDING CONTROL BUILDING EXHAUST 650 24 24 6" ACOUSTIC NOTES: 1. SEE SECTION 10.10200 FOR ADDITIONAL REQUIREMENTS. 650 CFM L -2 BACKFLOW PREVENTER SCHEDULE SQ. FT. SQUARE FEET V SIZE PRESSURE VOLUME DAMPER TAG NO. LOCATION TYPE (INCHES) RATING NOTES WC WATER CLOSET WEIR WALL EXHAUST OR RETURN WG WATER GAUGE RPBA CONTROL REDUCED 1 175 1 BUILDING PRESSURE NOTES: 1. SEE SECTION 10.15400 FOR ADDITIONAL REQUIREMENTS. NC NORMALLY CLOSED NO NORMALLY OPEN I SP =60 F OSA OUTSIDE AIR I P PUMP PD PRESSURE DROP i CONTROL BUILDING CONTROL BUILDING PROP PROPELLER I PW POTABLE WATER I RF RETURN FAN RPBA REDUCED PRESSURE BACKFLOW ASSEMBLY RPM REVOLUTIONS PER MINUTE 02173 SP STATIC PRESSURE /SET POINT SQ. FT. SQUARE FEET V VENTILATING VD VOLUME DAMPER VTR VENT —TO —ROOF VVT VARIABLE VOLUME /TEMPERATURE WB WET BULB WC WATER CLOSET WEIR WALL EXHAUST OR RETURN WG WATER GAUGE WH WATER HEATER WSD WALL SUPPLY DIFFUSER Kennedy /Jenks Consultants 32001 32nd Avenue South, Suite 100 Federal Way, WA 98001 Ph. 253 - 8358400 Fax 253 - 952 -3435 HVAC SCHEMATIC 650 CFM HOT BOX W, 1" PW RPBA PLUMBING SCHEMATIC RECORD DRAWING ihma Record Drawings haw from paW brad m mfmmo5on provided by the cmtrockr aM off m Kennedy /Jenks W WEmh ham not wrife0 the ocmwM a cmVWWt of i fomMm provided to them and dm not •arrant the aaamay ar a Oetemm of them Reomd Dmwk* . Ue of thma Racard Drawings mama all rIBk of Im romMM flan their me. av� ` 5 -3 �3 �