3 METER _ MCC 4IMTS, - - 40 0A/3P I 1� UnuTY POWER qGj — - 00A UTILITY TRANSFORMER — — — 12470- 48OV/277V, 30 N 4 I G I I I I I 9 ATS 400A, 480V, 30 GROUND RODS RO ILL Roth Hill, LLC Te1425.869.9448 www.rothhiii.com 11130 NE 33rd Place, Suite 200 Bellevue, WA 98004 MCC _ _ _ _ MCC, 600A, 480/277V, 3- PHASE, 4 -WIRE, 42KAIC I I aD aD I50A /3P ) 150A/3P I I� P -210 PUMP MOTOR Kennedy /Jenks Consultants 32001 32nd Avenue South, Suite 100 Federal Way, WA 99001 Ph. 253 -935 -9400 Fax 253 - 9523435 P -220 PUMP MOTOR GENERATOR ENCLOSURE LOAD BANK I I ) XXXA /3P 3 I � I XXXA /3P 175 KW XXKAIC OEN I I I I N I I I G I V J 15A/3P o ` 30A /3P o ` 60A /3P I T1 J\ 15KVA 480- 120/208 SPD 34, 4W MCB 50A 30 CKT -- -- PNL -L1 -- -- -- ONE LINE DIAGRAM SCALE: NONE V J 20A /3P I PFR I I N1nTP_1,- NEW TRANSFORMER TO BE PROVIDED AND INSTALLED BY UTILITY ON (N) VAULT. TRENCH TO NEW TRANSFORMER BY CONTRACTOR PER UTILITY REQUIREMENTS. UTILITY METER BASE AND CT ENCLOSURE BY CONTRACTOR PER UTILITY REQUIREMENTS. SYSTEM GROUND BUS SHALL BE COPPER 2" X %" X 12" MINIMUM. CONNECT GROUNDING ELECTRODE CONDUCTORS TO GROUND BUS BE EXOTHERMIC WELDING. LISTED PRESSURE CONNECTORS, OR LISTED CLAMPS. SOLID -STATE STARTER CIRCUIT BREAKER SIZE SHALL BE CONFIRMED BY SOLID -STATE STARTER MANUFACTURER. © ATS AND MTS (MANUAL TRANSFER SWITCH) INSTALLED IN MCC LINEUP. GENERATOR BREAKER SHALL BE CAPABLE OF INTERRUPTING THE MAXIMUM FAULT CURRENT THAT THE GENERATOR IS CAPABLE OF PRODUCING. ® MAIN BONDING JUMPER. ENSURE THAT THE SYSTEM NEUTRAL IS GROUNDED ONLY AT THE SERVICE ENTRANCE DISCONNECT. ENSURE THAT THE SYSTEM IS NOT GROUNDED AT THE AUTOMATIC TRANSFER SWITCH, THE MAIN CONTROL PANEL OR THE GENERATOR. GROUND RODS SHALL BE PLACED AT LEAST 16' APART. 10 VENDOR CABLE FROM THE PUMP. 11 TERMINATION BOXES (HAZARDOUS AREA TO NON- HAZARDOUS AREA) WITH TERMINAL BLOCKS, TO TRANSITION FROM PUMP CABLES TO FIELD WIRING OUTSIDE THE CLASSIFIED AREA. BOXES TO BE MARKED "ELECTRICAL" AND "CONTROLS" RESPECTIVELY, SEE SHEET E9. 12 NOT USED 13 LOAD BANK BREAKER SHALL BE CAPABLE OF INTERRUPTING THE MAXIMUM FAULT CURRENT THAT THE GENERATOR IS CAPABLE OF PRODUCING. ARK -TITE GENERATOR RECEPTACLE 400A, 4 -POLE, WITH GROUND. RECORD DRAWING These Record Drawings hero boon prepared based an Mermolfon provided by the contractor and otllae. KenaedJ /Z, ConsYOmb hro sat verified the amaacy or cumplatereres of IrderrnaUUn I melded to them and does not vanard the owmacy or compWiareas of theme Record paeips. User, of trees Record Drawings camme all risk of lees resultin from their use. 0-i3 I