� SANITARY SEWER NOTES 8c SPECIFICATIONS
�-- Sanitary Sewer Notes and Specifications
E— THESE NOTES SHALL APPEAR ON PROJECTS FOR THE SANITARY SEWER UTILITY.
�-- 1. All work and work material shall be in conformance with the standards and
specifications of the City of Renton Planning /Building /Public Works Department
and the latest edition of the WSDOT /APWA Standards and Specifications, as
approved and modified by the City of Renton in the Renton Standard Plans &
CL Specifications. A set of approved plans shall be kept on site at all times
10- during construction.
0- 2. The hours of work in the street right of way shall be per City specifications
on weekdays unless otherwise approved in writing by the Planning /Building /Public
Works Department. An approved traffic control plan must be obtained prior to
beginning any work within public right of way.
3. All locations of existing utilities shown are approximate and it shall be the
contractor's responsibility to verify the true and correct location so as to
avoid damage or disturbance.
4. A pre- construction conference and a 24 hour notice shall be required prior to
starting new construction. It shall be the contractor's responsibility to
secure all necessary permits prior to starting construction. (Inspection will
be accomplished by a representative of the City of Renton.) It shall be the
contractor's responsibility to notify the Public Works inspector 24 hours in
advance of backfilling all construction.
5. Contractor is solely responsible for the means, methods and sequences of
construction and for the safety of workers and others on the construction site.
6. It shall be the responsibility of the contractor to obtain street use and any
other related permits prior to any construction.
7. Plans approved by the City of Renton, Public Works Department shall take
precedence over all other plans.8. A copy of these approved plans must be on the
job site whenever construction is in progress.
9. The contractor shall provide the City of Renton with an as -built drawing of
the sanitary sewer system, which has been stamped and signed by a licensed
professional engineer or licensed professional surveyor.
10. Backfill shall be placed equally on both sides of the pipe in layers with a
loose average depth of 6 inches, maximum depth of 8 inches, thoroughly tamping
each layer to 95 percent of maximum density. These compacted layers must extend
for one pipe diameter on each side of the pipe or to the side of the trench.
Materials to complete the fill over pipe shall be the same as described.
11. Open cut road crossings for utility trenches on existing traveled roadway
shall be backfilled with crushed rock and mechanically compacted unless
otherwise approved by the Public Works inspector. Cuts into the existing
asphalt shall be neatline cut with saw in a continuous Fine. A temporary mix
patch must be placed immediately after backfill and compaction. A permanent hot
mix patch shall be placed within 10 days and shall be per City of Renton current
standards.
12. Datum shall be City of Renton, 1988 NAVD.
13. All disturbed areas shall be seeded and mulched or otherwise stabilized to
the satisfaction of the Department for the prevention of on -site erosion after
the completion of construction.
14. All pipe and appurtenances shall be laid on a properly prepared foundation
in accordance with the standards and specifications of the City of Renton
Planning /Building /Public Works Department and the latest edition of the
WSDOT /APWA Standards and Specifications, as approved and modified by the City of
Renton in the Renton Standard Plans & Specifications. This shall include
necessary leveling of the trench bottom or the top of the foundation material,
as well as placement and compaction of required bedding material, to uniform
grade so that the entire length of the pipe will be supported on a uniformly
dense, unyielding base. Pipe bedding shall be as required from the pipe bedding
standards, Detail 6077.
15. Sanitary sewer pipe shall be polyvinyl chloride (PVC) rubber gasketed ASTM D
3034, SDR 35, or ductile iron class 50, unless otherwise approved by the
Wastewater Utility.
16. In unimproved areas, manhole to extend n
inches above finished grade or must have min
poured at grade. In paved area, cover must sl
paving.
RECESSEC
LIFT POCI
/ J" — 11
(BRONZE
\4<z "x2 "1
1 J"
I
1 1„
4
�— " --j
12 2 :""
14",
CAST IRON RING AND COVER
w
! PROPERTY LINE
SIDE SEWER MAIN TO BUILDING SEWER
c
? I FUTURE
6 " SEWER PIPE 6 ° BLDG SEWER
6" SIDE OUTLET TEE ?; 2"X4" STUD SERVICE MI RKER
PAINT UPPER PORTION WHITE
w AND STENCIL ON SIDE WORD
ICU ° "SE WER " WI TH 3 " HIGH
BLACK LETTERS.
6" SIDE SEWER & BUILDING SEWER
PLAN
6" SIDE SEWER
1: J. 5 MIX NOTE:
CONCRETE 60° ALLOWABLE MAX SIDE SEWER SHALL HA VE A
BLOCKING FOR CAST OR MINIMUM 5' COVER AT PROPERTY
DUCTILE IRON PIPE. LINE OR 3 -5' LOWER THAN THE
6 "MIN 45° MAX LOWEST HOUSE ELEVATION, WHICH -
25' MIN EVER IS L O WER.
6 "MIN HORIZONTAL
6" SIDE OUTLET TEE
SEWER MAIN
EXISTING SEWER MAIN
CONC. BLOCKING ANGLE -1-1-6" SIDE SEWER
OF TEE AT MAIN OVER 25 °
ELEVA TION 6 "TEST TEE
TO BE INSTALLED
00� G A T CONNECTION
��,� G ` ,A NOTE.
GCE ;\_0 MAKE TAP THROUGH CAST IRON
SADDLE SECURED TO SEWER MAIN
WITH STAINLESS STEEL BANDS
Z* HORIZ�ONTAL G0WHEN CONNECTING NEW SIDE
SEWERS TO EXISTING MAIN.
29. MIN SLOPE
VI TRIFIED CLAY, PLAIN &
TYPICAL SIDE SEWER REINFORCED CONCRETE, D1 &
C1 PIPE SEWER MAINS ARE TO
ELEVA TION BE CORE DRILLED.
SIDE SEWER SER VI C DETAIL
TYP. SEE SH TS. 15 & 16
1' 1' 2.5' 1' 1'
MIN MIN MIN MIN MIN
CONCRETE
CLASS 3000
Z TIGHT
M
2" CLAS
Y1
REVISION
2„
CLA
CLA
OF CURB OR
OF PAVEMENT
25"
4" MIN.
N
=a
48"
i
CASTING INLAND FDRY
OR EQUAL. P T,#714
SEE DETAIL 5.1.4
ADJUSTMENT 4" MIN.
CONE
MORTAR JOINTS
- ,I
STEPS -314" DEFORMED BAR
STEPS SHALL BE INCLUDED
6 1/2"
CONRETE RISER BY PIPE INC.
OR APPROVED EQUAL
MAX. PIPE SIZE -21" 1. D.
LADDER —STD. ALUMINUM
OR GALVANIZED STEEL.
CONCRETE SHELF
MORTAR F LET
PRECAST BASE SECTION
OR CAST IN PLACE
6" MIN.
6„ MIN.
SANITARY MANHOLE TYPICAL DETAIL
(N TS)
NOTES:
1. STEPS TO BE 3/4" 0 DEFORMED BAR GALVANIZED SAFTEY STEPS OR EQUAL
2. STEPS ARE TO BE IN PLACE BEFORE MANHOLE SECTI ❑NS ARE INSTALLED
3. CASTING TO BE PER DWG. DR29
4. MANHOLE SECTIONS TO BE OF REINFORCED PRECAST CONCRETE
5. ALL JOINTS SHALL BE GROUTED,
6. SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR
SURFACES, INCLUDING CHANNELING, COATED (SEALED)
WITH A HIGH SOLIDS URETHANE COATING;
WASSER MC- C❑NSEAL OR APPROVED EQUAL;
COLOR OF COATING SHALL BE WHITE.
7. RUBBER GASKETTED JOINTS SHALL BE IN CONFORMANCE WITH ASTM C -443,
8. CHANNEL HEIGHT SHALL BE A MINIMUM OF 3/4 THE INSIDE DIAMETER
OF THE LARGEST PIPE.
9. CONNECTIONS TO MANHOLE SHALL BE MADE USING GPK ADAPTOR,
KOR -N -SEAL BOOTS OR APPROVED EQUAL,
EDGE OF EXISTING /NEW
FA/C ROADWAY (TYPICAL)
2" CLASS `B'
OVERLAY
;ENTER LINE OR
.ANE LINE
VARIES
1' 2.5 1'
MIN MIN MIN
a .:Q
GRAVEL /GRADE SHOULDER
A NEEDED (TYPICAL)
—ACP CLASS `E' OR `B'
6" CRUSHED
SURFACING TOP COURSE
CRUSHED ROCK,
FLOWABLE FILL
OR AS REQUIRED BY ENGINEER
WASH °
VARIES 1
2" DEPTH OF TOUMA ENGINEERS AND 00 - z
GRIND OR SAWCUT AND REMOVE LAND - URVEYOR ,PLLC 9470
,/ El V /� T PAT(HR-23) CIS
A VEl1/l C H DETAIL 6632 SOUTH 191ST PLACE, SUITE E -102 °KENT, WA 98032 SSrONAL ��
TYP. SEE SH TS. 1 PHONE (425) 251 -0665 FAX (425) 251 -0625
Lypms: