Loading...
HomeMy WebLinkAboutS-348503®4; W Q Z F- 0 W drm O D_ Lu IZ LL Lu 3: ui cc MW dml ri +: `s F � f,r %1 EXPIRES: 11/10/09 �' CALL >.� �,. HW 1 m 1-60`00=424,5M BACKFILL MATERIAL (SEE NOTE 5) — CONCRETE CLASS C (SEE NOTE 8) — FOUNDATION LEVEL BACKFILL MATERIAL (SEE NOTE 5) — BEDDING MATERIAL FOR RIGID PIPE (SEE NOTE 6) — FOUNDATION LEVEL BEDDING MATERIAL FOR FLEXIBLE PIPE (SEE NOTE 7) — FOUNDATION LEVEL NOTES: 1. PROVIDE UNIFORM SUPPORT UNDER BARREL. 2. HAND TAMP UNDER HAUNCHES. W (SEE NOTE 4) LIMITS OF PIPE ZONE I C LENGTH( BEDDING CLASS DESIGN DIMENSION CLASS A CLASS B CLASS C PROPERTY LINE Y B B 200 6" MIN. Z * »A z 300 to 350 _ (CLASS DESIGN) �— 6" MIN. 6" MIN. ZERO 6" MIN, 139 12" MAX. 6" BUILDING SEWER PIPE � BUILDING SEWER W (SEE NOTE 4) LIMITS OF PIPE ZONE 124 144 w ? 2 "x 4" STUD SERVICE MARKER PAINT 1/4 O.D. 1/2 O.D. 1/8 O.D. TEE WITH 6" SIDE OUTLET UPPER PORTION WHITE ANS STENCIL ON O.D. C 3/4 O.D. SIDE WORDING "SEWER" WITH 3" HIGH 6 O.D. — a BLACK LETTERS. AND #6 WIRE WRAPPED 312 298 286 AROUND THE STUD AND EXTENDED TO THE a TOP OF THE STUD. 268 261 255 371 C 371 3525 G" SIDE SEWER AND BUILDING SEWER (CLASS B, C, D, DESIGN) BEDDING FOR RIGID PIPE W (SEE NOTE 4) LIMITS OF PIPE ZONE ,I , 10„ (CLASS F DESIGN) BEDDING FOR FLEXIBLE PIPE 3. COMPACT BEDDING MATERIAL TO 95X MAX. DENSITY EXCEPT DIRECTLY OVER PIPE. HAND TAMP ONLY. 4. SEE "EXCAVATION AND PREPARATION OF TRENCH" IN THE SANITARY SEWERS SECTION OF THE STANDARD SPECIFICTATIONS FOR TRENCH WIDTH "W" AND TRENCHING OPTIONS. THE PIPE ZONE WILL BE THE ACTUAL TRENCH WIDTH, EXCEPT FOR CLASS A BEDDING. THE MINIMUM CONCRETE WIDTH SHALL BE 1 -1/2 I.D. + 18 ". 5. TRENCH BACKFILL SHALL CONFORM TO "BACKFILLING SEWER TRENCHES' IN THE SANITARY SEWERS SECTION OF THE STANDARD SPECIFICATIONS, EXCEPT THAT ROCKS OR LUMPS LARGER THAN 1" PER FOOT OF PIPE DIAMETER SHALL NOT BE USED IN THE BACKFILL MATERIAL. 6. SEE "BEDDING MATERIAL FOR RIGID PIPE" IN THE AGGREGATES SECTION OF THE STANDARD SPECIFICATIONS FOR THE MATERIAL SPECIFICATIONS. 7. SEE "BEDDING MATERIAL FOR FLEXIBLE PIPE" IN THE AGGREGATES SECTION OF STANDARD SPECIFICATION FOR THE MATERIAL SPECIFICATIONS. 8. PIPE MUST BE ANCHORED IN SUCH A MANNER AS TO ENSURE FLOW LINE IS MAINTAINED. 2 -21 -91 LANE LINE MARKING 7' -8" STANDARD VEHICLE WHEEL PATH CRUSHED ROCK, FLOWABLE FILL OR AS REQUIRED BY ENGINEER *MINIMUM ACP CLASS 'E' or 'B' SHALL BE: PRINCIPAL /MINOR /COLLECTOR ARTERIAL STREETS do INDUSTRIAL ACCESS STREETS — 6" ACP CLASS 'E' or W. RESIDENTIAL ACCESS STREETS — 2" ACP CLASS 'E' or W. NOTE: UPON REQUEST OF ENGINEER, NEW ROADWAY PAVEMENT UNLESS OTHERWISE APPROVED BY THE CITY, MAKE TAP THROUGH CAST IRON SADDLE SECURED TO SEWER MAIN WITH STAINLESS STEEL BANDS WHEN CONNECTING NEW SIDE SEWERS TO EXISTING MAIN. PLAIN AND REINFORCED CONCRETE, DI PIPE AND Cl PIPE SEWER MAINS ARE TO BE CORE DRILLED. VITRIFIED CLAY PIPE SHALL BE CUT AND HAVE A NEW TEE SECTIONED IN. ' \— 6" SIDE OUTLET TEE SEWER 6" MIN. MAIN CONCRETE BLOCKING ANGLE OF TEE AT MAIN OVER 25 ELEVATION HORIZONTAL SEWER MAIN TYPICAL SIDE SEWER ELEVATION NOTE: UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2.5' COVER AT PROPERTY LINE OR 3 -5' LOWER THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER. 2" CLAS *2" TO 6" C OR C! -MIN MIN MIN' MINIMIN 2" CLASS 'B' CRUSHED ROCK, FLOWA6L.L- I [-L- OR AS REQUIRED BY ENGINEER 6.5' MIN. 2" DEPTH OF GRIND OR SAWCUT AND REMOVE 6.5' MIN. 1° 1' 2.5' 1' 1' MIN MIN r MIN MIN MIN * FOR MINIMUM STANDARDS, SEE DWG# HR -05, SP PAGE H032 )R S* D SURFACING TOP COURSE LENGTH( BEDDING CLASS DESIGN DIMENSION CLASS A CLASS B CLASS C CLASS D CLASS F 200 6" MIN. 400 450 z 300 to 350 A 1/4 I.D. 6" MIN. 6" MIN. ZERO 6" MIN, 139 12" MAX. 170 170 124 144 8 1/4 O.D. 1/2 O.D. 1/8 O.D. ZERO O.D. C 3/4 O.D. 1/2 O.D. 1 i/8 O.D. O.D. — LANE LINE MARKING 7' -8" STANDARD VEHICLE WHEEL PATH CRUSHED ROCK, FLOWABLE FILL OR AS REQUIRED BY ENGINEER *MINIMUM ACP CLASS 'E' or 'B' SHALL BE: PRINCIPAL /MINOR /COLLECTOR ARTERIAL STREETS do INDUSTRIAL ACCESS STREETS — 6" ACP CLASS 'E' or W. RESIDENTIAL ACCESS STREETS — 2" ACP CLASS 'E' or W. NOTE: UPON REQUEST OF ENGINEER, NEW ROADWAY PAVEMENT UNLESS OTHERWISE APPROVED BY THE CITY, MAKE TAP THROUGH CAST IRON SADDLE SECURED TO SEWER MAIN WITH STAINLESS STEEL BANDS WHEN CONNECTING NEW SIDE SEWERS TO EXISTING MAIN. PLAIN AND REINFORCED CONCRETE, DI PIPE AND Cl PIPE SEWER MAINS ARE TO BE CORE DRILLED. VITRIFIED CLAY PIPE SHALL BE CUT AND HAVE A NEW TEE SECTIONED IN. ' \— 6" SIDE OUTLET TEE SEWER 6" MIN. MAIN CONCRETE BLOCKING ANGLE OF TEE AT MAIN OVER 25 ELEVATION HORIZONTAL SEWER MAIN TYPICAL SIDE SEWER ELEVATION NOTE: UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2.5' COVER AT PROPERTY LINE OR 3 -5' LOWER THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER. 2" CLAS *2" TO 6" C OR C! -MIN MIN MIN' MINIMIN 2" CLASS 'B' CRUSHED ROCK, FLOWA6L.L- I [-L- OR AS REQUIRED BY ENGINEER 6.5' MIN. 2" DEPTH OF GRIND OR SAWCUT AND REMOVE 6.5' MIN. 1° 1' 2.5' 1' 1' MIN MIN r MIN MIN MIN * FOR MINIMUM STANDARDS, SEE DWG# HR -05, SP PAGE H032 )R S* D SURFACING TOP COURSE PROCEDURE: 6 IN. DIAMETER LENGTH( PIPE w 0 a a. 50 100 150'i cc 100 w 150 200 0 250 400 450 z 300 to 350 20 400 59 450 PROCEDURE: 6 IN. DIAMETER PIPE 0 50 100 150'i 200 =250 300! 350 400 450 500 0 20 40 59 79 _ 98 118' 139 158 170 170 124 144 163 183 203 223 243 237 x:231 225 221 247 267 287 307: 312 298 286 276 268 261 255 371 391 371 3525 336 323 312s 302 293 286 278' 425 402 383 366 352 340 329' 320 312 304 298' 425 406 390 376 363 352 342' 333 326 318 312' 4251 _409 395 383? 371 361 c336 329 323: 425 411 399 388' 378 368 345 338 332! 425 413 402 392 383 374 M3524 352 346 340 425 414 404 395 387 379 358 352 347' TIME , SECONDS llaM;L-I ?3a1 W - 11 N.C. SOCKET HD SCREW i 1G" LONG (BRONZE OR S.S.) Jr c 2" RAISED PADS 12 Ys 14" 45' (1/8) BEND —� e- + 0 1 •' CONCRETE CLASS 3000 WATER TIGHT PLUG PIPE MATERIAL AS SPECIFIED BY THE ENGINEER PLUG TO BE SEALED IN SAME MANNER AS MAIN SEWER" JOINTS. NOTES: 1. 8" CLEANOUTS SHALL BE EASE JORDAN IRON WORKS, INC. No. 3698 OR EQUAL. CLEAN OUT SHALL BE A WATER TIGHT ASSEMBLY. a OR a Dw CxzmuT 2. IN UNIMPROVED AREAS, POUR A 1' -0" THICK, 2' -0" SQUARE CONCRETE, CLASS 3000, PAD AROUND THE RING AND COVER. 4. IN ASPHALT ROADWAYS, RESTORE AROUND CLEANOUT RING AND COVER AS REQUIRED BY STANDARD DETAIL DRAWING BR36. ADOPM "MININ11 FIELOBOOK: PAGE: