Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
S-357615
trr t- w 0 a Z _0 W ICZ G a- _j 0 0 U _0 cr W m J NAMEPLATE RUN -TIME METER AMMETER DISPLAY RESETTABLE OPERATION FITTIT COUNTER %X O MANUAL BYPASS ENABLED PUMP OVERTEMP LIGHT PUMP SEAL FAIL LIGHT LQ PUMP RUN LIGHT PUMP FAIL UGH 0 DISCONNECT SWITCH AMMETER SELECTION SWITCH CAPACITOR OFF -AUTO SWITCH / BYPASS- SOFTSTART KEY SWITCH © EMERGENCY / -STOP BUTTON PUMP FAIL ALARM RESET BUTTON IIII����IIII SOFTSTART RESET BUTTON TYPICAL SOFT START PANEL DETAIL NOT TO SCALE AMMETER DISPLAY AMMETER SELECTION SWITCH HAND -OFF SWITCH EMERGENCY STOP BUTTON NAMEPLATE DISCONNECT SWITCH OPERATION COUNTER RUN -TIME METER PUMP RUN LIGHT ALARM RESET BUTTON PUMP OVERTEMP LIGHT PUMP FAIL LIGHT PUMP SEAL FAIL LIGHT TRANSFER PUMP PANEL DETAIL PROPOSED MOTOR CONTROL CENTER SHALL HAVE A DEPTH OF 15'. 6' -8' MOTOR CONTROL CENTER LAYOUT 1" = 1' -01" PROPOSED HOUSEKEEPING PAD. SEE DWG NO. E07 FOR DETAILS. MCC CONTROL DEVICES BOTHELL SECTION EAST WE N AT CHEE IA TACOMA ID BELLINGHAM NGI N SILVERDALE PLANNERS RICHLAND SCIENTISTS TRANSFER PUMP NO. 3, P -3 (800) 720.8052 RH2 PROJECT NO. ESM 110.052 PROPOSED MOTOR CONTROL CENTER SHALL HAVE A DEPTH OF 15'. 6' -8' MOTOR CONTROL CENTER LAYOUT 1" = 1' -01" PROPOSED HOUSEKEEPING PAD. SEE DWG NO. E07 FOR DETAILS. MCC CONTROL DEVICES MCC SECTION NAMEPLATE SCHEDULE IA MCC MAIN DISCONNECT ID POWER MONITOR 1G SPD DISCONNECT 11 SPD 1J TRANSFER PUMP NO. 3, P -3 PUMP RUN PUMP FAIL PUMP OVERTEMP PUMP SEAL FAIL EMERGENCY STOP P -3 HAND -OFF START COUNTS ELAPSED TIME (HOURS) ALARM RESET 2A LIGHTING PANELBOARD '1° 2H PHASE FAIL RELAY 21. TRANSFORMER DISCONNECT 2J LIGHTING TRANSFORMER 3A PUMP N0, 1, P -1 PUMP RUN PUMP FAIL PUMP OVERTEMP PUMP SEAL FAIL EMERGENCY STOP MANUAL BYPASS CAPACITOR OFF /AUTO P -1 BYPASS - SOFTSTART EMERGENCY STOP ALARM RESET ELAPSED TIME (HOURS) START COUNTS SOFTSTART RESET 3K PUMP NO. t, P -1, POWER FACTOR CORRECTION CAPACITOR 4A PUMP NO. 2, P -2 PUMP RUN PUMP FAIL PUMP OVERTEMP PUMP SEAL FAIL EMERGENCY STOP MANUAL BYPASS CAPACITOR OFF /AUTO P -2 BYPASS- SOFTSTART EMERGENCY STOP ALARM RESET ELAPSED TIME (HOURS) START COUNTS SOFTSTART RESET 4K PUMP NO. 2, P -2, POWER FACTOR CORRECTION CAPACITOR 5- 351615 AV SHOWN X0fl20Nt�"10 t9��f991 CITY OF ISSAQUAH SCHOOL DISTRICT 2010 —Os CMR LIBERTY HIGH SCHOOL PUMP STATION RENTON MWB E05 IMLM ^ *� Planning /Building /Public Works Dept. MOTOR CONTROL CENTER DETAILS IF NOT p!E WCN /11 1/19/11 NO. REVISION BY DATE APPR �HMY sm: 15 m'21 CAD , :5 -3576 15