Loading...
HomeMy WebLinkAboutS-362005SANITARY SEWER PROFILE EV2, SEC. 10, T. 23 N", R. 5 E., W.M. 1 11 =20 (HORIZON) 1"=10' (VERTICAL) 450 EXS GRADE FINISHED GRADE - z ° STREET GRADE OVEI Z SEWER FINISHED GRADE E ISTING GR DE OVER S WER - - ° OVER EXISTING SEWER OVER SEWER i � 440 ± OVEF MINIMUM 440 Z rV O N LLI d 430 CO 430 U � w / SSM #4 LtJ 8" 4 LF 8 "P C STD .1 48' LF " 8+50.00, 170.1 LT OG 420 N r.v. 420 UJI 00.5% SSMH #2 SSMH #3 TE 444 MH TYPE B 54" MH TYPE B 54" IE =430.0 W EXIS NG SEWER LINE S MH #1 N W MH 48° 6 +47.32. 12.16 LT 7 +15.58, 170.18 LT B ETZKE 05 35. 0.5 . 0.5 T SSMH 3 W 1--� 410 410 Z IE= 428.95 TE =435.5 SSMH VERIFY T LINE = 439.0 AND INVERTS IE= E 429.05 IE 429.40 N (a/I TES4 IE 429.50 E IE =41 .5(EXST,) IE 428.10 E IE 428.00 IA m 400 I 400 n M MH #1 is saddle 48" MH 00 In Lq z N MH #2 and 3 are Tyoe B 54" M M M od O o O 3 MH #4 is standard 48 MH �z ~ W a 5+00 5 +50 6 +00 6 +50 7 +00 7+50 8 +00 8 +50 U� m v MANHOLE FRAME AND 'COVER b "�. SEE STD. PLAN 401 MANHOLE FRAME AND COVER m / c PROPERTY LINE - - - ADJUSTMENT RINGS (2" MIN.) MAX 24 12" ' - SEE NOTE s �" PER DRAWING 401. 1_ 3•_0`• _ frJiU£z€ E" BUILDING SEBA€R PIPE UI ADING $EWER - MORTAR JOINT(5) (3/8' MIN.) 1 SEE NOTE 5 -- CONE (ECCENTRIC} r ADJUSTMENT RINGS (2" MIN.) SEE NOTE 6 S" � $� 40 \. RUBBER GASKETED JOINTS IN .. ACCORDANCE WITH ASTM C -443 MORTAR JOINT ( S) (3/8" MIN) SEE NOTE 5 .. ' TO M� +,� 2•Ir 4 "STUD MARKING PQ;aT PA4NTE0 "NS'k6" 2MIN- --����.... i ¢ o YEE WITH W' SM CUTLET '8 'A32 €TE MTTH THE 15i1RD 'SEWER' STENCILED -IJ CLE'ANOUT IN 9 HIGH RACK LETTERS AND WINE ,C, +� ¢ v � ,e -' ° -�� � �4 T IR COVEN omE WITAFFE€} AROUND T1TE 47TTD AND CAST 1JQ <� , AN IR EAST JDRbAN IRON EQUAL. EXTENDED TO RtE TOP (iF THE STUD. 97D fX2 APPR0I�D EQUAL. SPECIFY STEPS - POLYPROPYLENE STEPS '" SHALL BE INCLUDED 8_ i /2„ ?4 24" > o 0 0 5 P.. P"N 40 FOR A,. <E SEW7E N. ' to 0 c INSTALLATION) 7' MIN W CL a A +. . <. +.. 12" v p g 0- II ACCEFTADLE RRiR€S FOR SIDE SOWER CONNECTORS TO MAIN Q LINES ARE AS FOULOWS3 CONCRETE RISER BY PIPE. INC:, } O A A. MIRIPIED GLAV MAIN - CUT IN A NEW TEE USING FLE%JOVE OR APPROVED EQUAL. 3- m � U p. .� CCIUPLtNGS (F "FAN00 OR APPiAD'9^c0 fiRUAL ). a. ,ate Ld O AS. o CONCRETE MAIN - CORE - DOLLED 1WTH. A ROMAC SADDLE (OR APPROVED EQUAL] _ 12' (TYP) '`. `. LADDER- POLYPROPYLENE 4' 54" C. PVC MAIN - GORE- DRILLED IWTH A WMAC SADDLE (OR APPROVED �.. } �_ SHALL BE ATTACHED TO MANHOLE Y ... o - .. N a v A j; m m EQUAL) OR CUT IN A NEW TEE US0IQ RIOIU WUPUNGS. m m m MAX. PIPE SIZE - 'E` D5 m m D. DUCTILE: FROM MAIN: - GDRE- DRILLED VATH A ROMAC SADDLE (OR ;� APPR(MO EQUAL) E <. MANHOLE GtANNEGiiOI - AT DRUF G TO S SHALL BE � � CONCRETE SHELF f � � 8 ILM5 ROCK- U AT MRP4i7FA0'RP1PB4 Klr?0?;K -OUTS DR INC i % 0 STRUCTURE SHALL BE CORK - DRILLED. a PRECAST BASE SECTION OR CAST N SHELF. '^^"`-- �'^�111 n. .. G' D9 W�tAE,9 Q ° ALLOWABLE MAX- R CAST IRON PIPE BB`'� e, L 1 NOT TO SCALE 6i OF 4WGTILE [R0N PIPE. 'A' NLT� ESCON REET f."'�.� Gp jEs BLOCKIN& �%f',qJ r aSIDEOUTLET '8:' `G` SDI 48" MH 48" f 6' MIN 5 "MIN. 24 MIN. 2T' I.D. " 4" 8' MIN. 5.5" MIN. 24" MIN. 24° I,D: i. STEPS TO BE POLYPROPYLENE SAFETY STEPS. 2. STEPS AIRE TO BE IN PLACE BEFORE MANHOLE SECTIONS .ARE INSTALLED. SHALL <TO ?LAS .0 61 �OR��' 4'C(zG. �9g 3. CASTING BE PER 40t Nm TAL E """V' MIN SLOPE 60" MH � 60" 8 MI30° 1�0': 4. MANHOLE SECTIONS TO pE OF REINFORCED PRECAST CONCRETE ALL JOINTS BETWEEN THE CONE, RISER RINGS, BRICKS AND CASTING SHALL 3E GROUTED, 6. ADJUSTMENT OF THE CASTIN0 TO GRADE SHALL BE ACCOMPLISHED WITH A EXPIRES 02/07/ I. STEPS TO BE POLYPROPYLENE SAFETY STEPS. COMBINATION OF ADJUSTMENT RINGS, BRICKS AND MORTAR ONLY, BRICKS SHALL SEWER BE STAG >GERED TO CREATE A RUNNING BAND OR t f2 BQYD, 6'° MIN MAIN SE54E§2 MAIN. 2. STEPS ARE TO BE IN PLACE BEFORE MANHOLE SECTIONS ARE INSTALLED. THE USE OF SHIMS IS PROHIBITED. 3. CASTING SHALL BE PER STD, PLAN 401. 4. MANHOLE SECTIONS TO BE OF REINFORCED PRECAST CONCRETE. 7. SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR SURFACES, INCLUDING CHANNELING, TYPICAL EME SEWER ELEVATION 5. ALL JOINTS BETWEEN THE CONE, RISER RINGS, BRICKS AND CASTING SHALL BE GROUTED. COATED (SEALED.) WITH A HIGH SOLIDS URETHANE COATING; 'WASSER MC- AROSHIELD OR APPROVED EQUAL, COLOR OF COATING SHALL ESE WHITE. 4F TEE AT MAIN OVER 7fi 6, ADJUSTMENT OF THE CASTING TO GRADE SHALL BE ACCOMPLISHED WITH A COMBINATION OF S RU88ER CiASKETEO JOINTS SHALL ESE IN CONFOFRMANCE VATH ASTM' C -443. £1.EVATION ADJUSTMENT RINGS, BRICKS AND MORTAR 0 Y, BRICKS SHALL BE STAGGERED TO CREATE A RUNNING BOND OR t/2 BOND. THE USE OF SHIMS IS 9. CHANNEL HEIGHT SHALL 8E A PJINIh,1UM OF 3/4 THE INSIDE DLAhdETER OF THE LARGEST PIPE. PROHIBITED 7. SANITARY SEWER MANHOLES SHALL HAVt ALL INTERIOR SURFACES, INCLUDING CHANNELING, 10 CONNECTIONS TO MANHOLE SHALL BE MADE USING GoPK ADAPTOR, KOR -N -SEAL '': z COATED (SEALED) WITH A HIGH SOLIDS URETHANE COATING; WASSER MC AROSHIELD OR BOOTS OR APPROVED EQUAL. iS IN I.i VEp AREAS, MANHOLES SHALL EXTEND A MINIMUM OF 6' Clip A IdAXIMUM OF r-1 0 U) N EJNLC$S 4TFIER4MSE SHOWN ON PLAN, SiOE 5€:WER SHA.iL N}A1rE APPROVED EQUAL; COLOR OF COATING SHALL BE WHITE 8. RUBBER GASKETED JOINTS SHALL BE IN CONFORMANCE tINSI DIA C -443, �OVE , 2" ABOVE FINISHER GRADE OR MUST HAVE A MINIAlUhd 2' DIAMETER CONCRET F.INGS PC.U?EL" AT GRkDE, IN PAVEG AREAS, COVER SLOPE ALL DIRECTIONS (V > A $dIPdIAfUM 'X.:6' COVC$2 AT PROF -'ERTY LAVE 0R 3-5' L6WF.1? 9. CHANNEL HEIGHT SHALL 8E A MINIMUM OF 3/4 OF THE INSIDE DIAMETER OF THE LARGEST PIPE. E MUST IN TO MAT/;H PFVING. THAN THE LOWEST HOUSE WL VATION, WHICHEVER IS LCIAER. 10. CONNECTIONS TO MANHOLE SHALL BE MADE USING GPK ADAPTOR, KOR� -N -SEAL UOOTS OR - Lo APPROVED EQUAL. 11. IN UNIMPROVED AREAS, MANHOLES SHALL EXTEND A MINIMUM OF 6' AND A MAXIMUM OF 12" ABOVE FINISHED GRADE Oft MUST HAVE A MINIMUM RINGS Ln =V PUBLIC STORKS SANITARY MANHOLE EAN' - .40lid 2' DIAMETER CONCRETE POURED AT GRADE. IN PAVED AREAS, COVER MUST SLOPE IN ALL DIRECTIONS TO MATCH PAVING.. eF .`2Y . p 6 PUBLIC WORKS OR STANDARD SANITARY IVIAPIIiCDLE STD. PLAN - 480.1 S "EFTEMBER -201 STANDARD SIDE SEWER SM.. Pw14 - 4011,1 F UE3LI 1MRNT8 INSTALLATION w. iiEPAkTMENT i�..M DEPARTMENT SHALLOW (SEWER MAIN TO PROPERTY LINE) SEPTEMBER. Ott � �: DEPARTMENT SEPTEMBER 2011 GO I 5 -3� act ®S ',. SHEET: 5 OF: 5 Z