Loading...
HomeMy WebLinkAboutS-362111w z 'o a f. H • ■t I..I 1 T LrL ^I vJ Q Z a_ z '0'^ VJ Z W X U.I (r I.LI LL1 0 cr— I- U) 0 1 0 0 U U) Q C� Q rn U) 112 PLUG AS DAM rTEE OF APPROPRIATE SIZE 11162towl "RELINER" BRAND STAINLESS STEEL ADJUSTABLE CLAMPING BRACKETS OR APPROVED EQUAL 3/4 THE DIAMETER OF THE DOWNSTREAM PIPE NOTES: 1. INSIDE DROPS ARE ONLY TO BE USED UPON APPROVAL BY THE WASTEWATER UTILITY SECTION. 2. ALL PIPES AND FITRNGS SHALL BE SIMILAR SIZE AND MATERIAL AS INCOMING MAINLINE 3. MINIMUM SIZE MANHOLE FOR INSIDE DROP CONNECTION SHALL BE 60' DIAMETER 4. CONNECTIONS TO MANHOLE SHALL BE MADE USING GPK ADAPTOR, KOR -N -SEAL BOOTS OR APPROVED EQUAL. 5. WITHIN A 60' DIAMETER MANHOLE, THE MAXIMUM ALLOWABLE DIAMETER OF THE INSIDE DROP PIPING IS 12'. INSIDE DROPS EXCEEDING 12' IN DIAMETER OR MULTIPLE DROPS SHALL BE RENEWED BY THE WASTEWATER UTILITY AND MAY REQUIRE A LARGER DIAMETER MANHOLE 6. 'RELINETY BRAND STAINLESS STEEL ADJUSTABLE CLAMPING BRACKETS OR APPROVED EQUAL SHALL BE INSTALLED WITHIN 6" OF BOTH BELL AND SPIGOT ENDS OF EACH DROP PIPE IF DROP PIPE LENGTH EXCEEDS 5 FEET THEN CENTER STRAPS SHALL BE INSTALLED WIN A MAXIMUM SPACING OF 4 FEET ON CENTER. BRACKETS SHALL BE ATTACHED UTILIZING STAIN'ESS STEEL EXPANSION BOLTS, MIN. 2 EACH AT CONNECTION POINTS. PUBLTC WOPJO I INSIDE DROP CONNECTIOP DEPARTMENT FOR SANITARY !MANHOLE WARNING: Fetlerel Way. WA 88008 eTpirt ur ( <+tc THE UTILITY LOCATIONS SHOWN WPM esmcivil.com Nto s, Is �_pp� ARE APPROXIMATE ONLY. DEPTH Gi.N gi P V a Plee lne Public Win I Pmpct Mc,agament I InMacape PxKitectun UNKNOWN. CALL 1- 800 - 424 -5555. ESM JOB #1352- 020 -011 BID. PLAIT — 402.8 AUGUST 2011 W (SEE NOTE 4) BEDDING MATERIAL FOR SANITARY SEWER PIPE (SEE NOTE 6) FOUNDATION LEVEL LIMITS OF PIPE ZONE V-0- D. OF PIPE BEDDING FOR SANITARY SEWER PIPE NOTES 1. PROVIDE UNIFORM SUPPORT UNDER BARREL. 2. HAND TAMP UNDER HAUNCHES. 3. COMPACT BEDDING MATERIAL TO 95% MAX. DENSITY EXCEPT DIRECTLY OVER PIPE. HAND TAMP ONLY. 4. SEE "EXCAVATION AND PREPARATION OF TRENCH" IN THE SANITARY SEWER SECTION OF THE STANDARD SPECIFICATIONS FOR TRENCH WIDTH "W' AND TRENCHING OPTIONS. THE PIPE ZONE WILL BE THE ACTUAL TRENCH WIDTH. 5. TRENCH BACKFILL SHALL CONFORM TO "9ACKFILLING" IN THE SANITARY SEWER SECTION OF THE STANDARD SPECIFICATIONS, EXCEPT THAT ROCKS OR LUMPS LARGER THAN I- PER FOOT OF PIPE DIAMETER SHALL NOT BE USED IN THE BACKFILL MATERIAL. S. PIPE ZONE MATERIAL SHALL BE "GRAVEL BACKFILL FOR DRAINS' AS SPECIFIED IN THE AGGREGATES SECTION OF THE STANDARD SPECIFICATIONS. 7. PIPE MUST BE ANCHORED IN SUCH A MANNER AS TO ENSURE FLOW LINE IS MAINTAINED. PUBLIC WORKS I PIPE BEDDING DEPARTMENT FOR SANITARY SEWERS �v i � � YErsnw: xnw Isae 1 SEDOND.SOSMOTAL ESM OS 1 NT$ xoN¢owru: Nw teen /feel O O� oNnwx: ONE INCH DATUM CXECKEO: gTRT N A SA IF NOT ONE ING1 NO. REVISION BY DATE APPR ems. SLUE ACEEMINGLY +74 +�jPissfbi MARCH 2005 5 -3621 CHECKED FOR COMPLIANCE TO CITY STANDARDS CITY OF HERITAGE PLAT SANITARY SEWER EXTENSION RENTON PHASE (LIBERTY HIGH SCHOOL) rlt Planning /Building /Public Works Dept. SANITARY SEWER DETAILS