Loading...
HomeMy WebLinkAboutS-366003HULTHALES - 3 PLCS CA"" EQUALLY SPACED Or cl• APART ON 23 L /16" ONmm) DIA B.C. <SEE DETAID C�• Www R E Yg� b} a NeFww COVER BOTTOM VIEW COVER $ FRAME W PLAR VIEW Lu 25' DIA�I 1635MO l 3' 31 BLT SDC. (ALLEN HEAD) 3/4, E25mn) 5/8• -11 X 1,5 SS 09. RUBBER WASHER ' 8 3/4' 2 1 00 BBZmm7 TYP E64mm) W Z COVER SECTION VIEW 0 EON BOLTING DETAIL co 26 1/2• DIA Lf) E67ALA 25 1/4' DIA L4, L641mn7 1 1/16' 1 lAS` L4' (6mN ALA EzE4-1 E6M0 T27mm7 NEDPRDE GASKET 5/8'� 23 3/8• DIA CL BEN [RS'mT Ctsmma 1594mm7 GASKET GROOVE DETAIL V 5/1V DIA 1694mm3 34 1/8' DIA E867mm) NQ=, FRAME SECTION VIEW t. ALL COVERS SHALL BE LOCKING LID PER EAST JORDAN IRON WORKS INC. No. 3717C1 OR EQUAL. 2, USE FRAME AND COWER FOR STORM (SPECIFY "DRAIN" ON COVER), SANITARY (SPECIFY "SEWER "), OR WATER (SPECIFY "WATER"). 9� 4 PUDLEC WORKS SM. PLAN - {01 MSS DEPARTMENT MANHOI.t FRAMR AND COVER DECEMBER 2008 FOUNDATION LEVEL B (CLASS B, C, D, DESIGN) BEDDING FOR RIGID PIPE I- W (SEE NOTE 4) LIMITS OF PIPE ZONE 1,-0„ BEDDING CLASS DESIGN SEAL WITH AR 4000 OR CLASS A CLASS B APPROVED EQUAL AND DRY CLASS D CLASS F SAND AFTER PATCHING NOTE 4) LIMITS OF PIPE ZONE PATCHED AREA PROVIDE UNIFORM SUPPORT UNDER BARREL I - --- A A 1/4 O.D. 1/2 O.D. COVER ZERO O.D. PLAN (SEE NOTE 50 1/2 O.D. NIS k. 2. 1 -0 DIA. - -{ T ASPHALT CLASS °8' APPROVED BY SEE SMD PLAN 401ND "OUTSIDE IFAS THE THE ENGINEER. RENTON UTILITY DEPARTMENT AND THE LATEST EDITION OF THE WSDOT /APWA STANDARDS AND SPECIFICATIONS. `` CONCRETE CLASS C 24" ADJUSTMENT RINGS (2" MIN.) 3. COMPACT BEDDING MATERIAL TO 95X. MAX. DENSITY EXCEPT DIRECTLY OVER PIPE. �. 4" CONCRETE 72" MAX SECTION A -A SEE NOTE 6 (SEE NOTE 8) ME>Es REMOVE PAVEMENT AND BASE MATERIALS FOR A DISTANCE ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH 'STANDARD SPECIFICATIONS FOR WadCH 6 ECOAL TQ THE DIAMETER OF THE FRAME PUS TWO FFET: ADJUST CASINO FRAME TO PAVEMENT SURFACE USNG RISER MM OR MORTAR JOINTS) (3/8" MIN.) CONCRETE BLOCK$ PER SM. PLAN 400.1. 4. SEE "EXCAVATION AND PREPARATION OF TRENCH" IN THE SANITARY SEWERS SECTION REPLACE ALL BUT TOP 2" OF E VAXD MATERMI. VAIN FOUNDATION LEVEL CLSS WAD CONCRETE (3/4). FIMW PAVEMENT SURFACE IC WM S" OF ASPHALT CLASS "B• OR AS.APPROVEO HV THE ENGINEER. t PUBLIC WORKS 4 I. TYPICAL UTIUTV COWER ADJU1fTMaT FOR STD. NAN - ODA CONE (ECCENTRIC) DEPARTMENT ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR'S BEDDING. THE MINIMUM CONCRETE WIDTH SHALL BE 1 -1/2 I.D. + 18 PAVIMENT OR OVERLAY DECEMBER 2010 RUBBER GASKETED JOINTS IN FOUNDATION LEVEL B (CLASS B, C, D, DESIGN) BEDDING FOR RIGID PIPE I- W (SEE NOTE 4) LIMITS OF PIPE ZONE 1,-0„ BEDDING CLASS DESIGN DIMENSION CLASS A CLASS B NOTES: CLASS D CLASS F W (SEE NOTE 4) LIMITS OF PIPE ZONE 1. PROVIDE UNIFORM SUPPORT UNDER BARREL I - --- BACKFILL MATERIAL 1/4 O.D. 1/2 O.D. 1/8 O.D. ZERO O.D. C (SEE NOTE 50 1/2 O.D. 1/8 O.D. k. 2. HAND TAMP UNDER HAUNCHES. SEE SMD PLAN 401ND RENTON UTILITY DEPARTMENT AND THE LATEST EDITION OF THE WSDOT /APWA STANDARDS AND SPECIFICATIONS. CONCRETE CLASS C 24" ADJUSTMENT RINGS (2" MIN.) 3. COMPACT BEDDING MATERIAL TO 95X. MAX. DENSITY EXCEPT DIRECTLY OVER PIPE. 72" MAX HAND TAMP ONLY. SEE NOTE 6 (SEE NOTE 8) 2. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH 'STANDARD SPECIFICATIONS FOR . _F MORTAR JOINTS) (3/8" MIN.) 4. SEE "EXCAVATION AND PREPARATION OF TRENCH" IN THE SANITARY SEWERS SECTION FOUNDATION LEVEL IC OF THE STANDARD SPECIFICTATIONS FOR TRENCH WIDTH "W' AND TRENCHING OPTIONS. / t THE PIPE ZONE WILL BE THE ACTUAL TRENCH WIDTH, EXCEPT FOR CLASS A ". CONE (ECCENTRIC) 3. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR'S BEDDING. THE MINIMUM CONCRETE WIDTH SHALL BE 1 -1/2 I.D. + 18 RUBBER GASKETED JOINTS IN RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE. ( CLASS A DESIGN ) r 5. TRENCH BACKFILL SHALL CONFORM TO "BACKFILUNG SEWER TRENCHES" IN THE ACCORDANCE WITH ASTM C -443 4. SANITARY SEWERS SECTION OF THE STANDARD SPECIFICATIONS, EXCEPT THAT ROCKS 2'k 4" STUD MARKER POST PAINTED WHITE WITH THE WOR "SEWER" STENCILED PROPERTY LINE 6 -1 /2" STEPS - POLYPROPYLENE STEPS SHALL BE INCLUDED OR LUMPS LARGER THAN 1" PER FOOT OF PIPE DIAMETER SHALL NOT BE USED IN THE AND FOR THE SAFETY OF WORKERS AND OTHERS ON THE CONSTRUCTION SITE. IN 3' HIGH BLACK LETTERS AND N WARE - - WRAPPED AROUND THE STUD AND BACKFILL MATERIAL W SEE ( NOTE 4 ) LIMITS OF PIPE ZONE 6. SEE "BEDDING MATERIAL FOR RIGID PIPE" IN THE AGGREGATES SECTION OF THE STANDARD SPECIFICATIONS FOR THE MATERIAL SPECIFICATIONS. 7' MIN. BACKFILL MATERIAL _f 7. SEE "BEDDING MATERIAL FOR FLEXIBLE PIPE" IN THE AGGREGATES SECTION OF (SEE NOTE 5) 12 6' STANDARD SPECIFICATION FOR THE MATERIAL SPECIFICATIONS. FUTURE 6. B. BE ANCHORED IN SUCH A MANER AS TO ENSURE FLOW LINE IS y BEDDING MATERIAL �� MAINTA ST FOR RIGID PIPE - - - J- (SEE NOTE 6) 7. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. i I FOUNDATION LEVEL B (CLASS B, C, D, DESIGN) BEDDING FOR RIGID PIPE I- W (SEE NOTE 4) LIMITS OF PIPE ZONE 1,-0„ BEDDING MATERIAL • A = 4" MIN. 27" I.D. AND UNDER FOR FLEXIBLE PIPE 6" MIN. OVER 27" I.D. (SEE NOTE 7) PIPE BEDDING FOR SANITARY SEWER FOUNDATION LEVEL ADOPTED CITY or BENT'ON A coh", STANDARD PLANS /rn ncc c nrrnru\ I8T DATE: 4/97 97 BEDDING CLASS DESIGN DIMENSION CLASS A CLASS B CLASS C CLASS D CLASS F A 4" MIN. 1/41.D. 12" MAX. • • ZERO I - --- B 1/4 O.D. 1/2 O.D. 1/8 O.D. ZERO O.D. C 3/4 O.D. 1/2 O.D. 1/8 O.D. O.D. - BEDDING MATERIAL • A = 4" MIN. 27" I.D. AND UNDER FOR FLEXIBLE PIPE 6" MIN. OVER 27" I.D. (SEE NOTE 7) PIPE BEDDING FOR SANITARY SEWER FOUNDATION LEVEL ADOPTED CITY or BENT'ON A coh", STANDARD PLANS /rn ncc c nrrnru\ I8T DATE: 4/97 97 o7 PIPE BEDDING FOR SANITARY SEWER \..-,.,... ..�..,..,., 4497 I 60" MH �A' 'B' �Y 'D' BEDDING FOR FLEXIBLE PIPE DWG. NAME: BW18C SP PAGE: 8077 2-21 -91 ReMeed notes. 4,5.7.& & Added note B KJ I - --- DATE REVISION BY APPR COVER I . o7 PIPE BEDDING FOR SANITARY SEWER I SEWER GENERAL NOTES MIX CONCRETE /P *Ny �pt+OG,K \TUG B. CONCRETE MAIN - CORE - DRILLED WITH ROMAC SADDLE I BLOCKING d' M \N 25 -y5 WC,HpE�'eV C. PVC MAIN-CORE-DRILLED EQUAL) (OR APPROVED EQUAL). CAN 2% MIN SLOPE UTWN H EWMTEE U LNG RIGD COUPU cs I 60" MH �A' 'B' 'C' 'D' 'E' I N� COVER I . ALL WORK MATERIALS SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY 65' MIN. 42" MIN. 30" I.D. 6" SEE SMD PLAN 401ND RENTON UTILITY DEPARTMENT AND THE LATEST EDITION OF THE WSDOT /APWA STANDARDS AND SPECIFICATIONS. 24" ADJUSTMENT RINGS (2" MIN.) 72" MAX SEE NOTE 6 2. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH 'STANDARD SPECIFICATIONS FOR . _F MORTAR JOINTS) (3/8" MIN.) MUNICIPAL PUBLIC WORKS CONSTRUCTION" PREPARED BY WASHINGTON STATE CHAPTER AMERICAN 'D' SEE NOTE 5 PUBLIC WORKS ASSOCIATION, LATEST EDITION (APWA) AND CITY OF RENTON STANDARD SPECIFICATIONS. CONE (ECCENTRIC) 3. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR'S RUBBER GASKETED JOINTS IN RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE. ,C, ACCORDANCE WITH ASTM C -443 4. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF CONSTRUCTION 2'k 4" STUD MARKER POST PAINTED WHITE WITH THE WOR "SEWER" STENCILED PROPERTY LINE 6 -1 /2" STEPS - POLYPROPYLENE STEPS SHALL BE INCLUDED AND FOR THE SAFETY OF WORKERS AND OTHERS ON THE CONSTRUCTION SITE. IN 3' HIGH BLACK LETTERS AND N WARE - - WRAPPED AROUND THE STUD AND 2E EXTENDED TO THE TOP OF THE STUD. 7' MIN. 5. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE AND ANY OTHER RELATED PERMITS PRIOR TO ANY CONSTRUCTION. b 12 •q• CONCRETE RISER BY PIPE INC., OR APPROVED EQUAL FUTURE 6. PLANS APPROVED BY THE CITY OF RENTON, PUBLIC WORKS DEPARTMENT, SHALL TAKE PRECEDENCE OVER ALL OTHER PLANS. 6" BUILDING SEWER PIPE y BUILDING SEWER - - - - - - - - J- 7. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. i I 12' (mm) MAX. PIPE SIZE - 'E' 8. THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WITH AN AS -BUILT DRAWING OF THE TEE WITH 6" SIDE OUTLET 6 "x6 "x6" WYE WITH A -� LADDER- POLYPROPYLENE SHALL BE ATTACHED TO MANHOLE SANITARY SEWER SYSTEM WHICH HAS BEEN STAMPED AND SIGNED BY A LICENSED PROFESSIONAL 6" SIDE SEWER AND BUILDING SEWER w ' SURFARON RINGOUTCWTH ' CONCRETE SHELF ENGINEER OR LICENSED PROFESSIONAL SURVEYOR. & rc (EAST JORDAN IRON WORKS ' & I 2975 OR APPROVED EQUAL, H 9. BACKFILL SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE PIPE IN LAYERS WITH A LOOSE SPECIFY °SEWER' ON UD, 1X. PRECAST BASE SECTION OR CAST IN SHELF. AVERAGE DEPTH OF 6 INCHES, MAXIMUM DEPTH OF 8 INCHES, THOROUGHLY TAMPING EACH LAYER TO SEE STD. PLAN 403.1 FOR - INSTALLATION) L / `• :�`A �. 95 PERCENT OF MAXIMUM DENSITY. THESE COMPACTED LAYERS MUST EXTEND FOR ONE PIPE DIAMETER ON EACH SIDE OF THE PIPE OR TO THE SIDE OF THE TRENCH. MATERIALS TO COMPLETE THE FILL OVER PIPE SHALL BE THE SAME AS DESCRIBED. 60" ALLOWABLE MAX. FOR CAST IRON PIPE ACCEPTABLE PROCEDURES FOR SIDE SEWER CONNECTIONS TO MAIN UNES ARE AS FOLLOWS: ,'�x .,H;'.,.;.:::'• ' _�( /,m \ OR DUCTILE IRON PIPE. /X��S A. VITRIFIED CLAY MAIN-CUT IN ANEW TEE USING FLEXIBLE XIB eI Y NOT TO SCALE I TU BACKFILLED WITH CRUSHED ROCK AND UTILITY ECHANICALLY COMPACTED. TRAVELED CUTSNTO ROADWAY SHALL BE ASPHALT IN A CONTINUOUS PLACED WITH NA10 DAYS AND HALL BE PER CITY OFNRENTON PERMANENT CURR NAT STANDARDS. RDSTCHMSHALB BE MIX CONCRETE /P *Ny �pt+OG,K \TUG B. CONCRETE MAIN - CORE - DRILLED WITH ROMAC SADDLE I BLOCKING d' M \N 25 -y5 WC,HpE�'eV C. PVC MAIN-CORE-DRILLED EQUAL) (OR APPROVED EQUAL). CAN 2% MIN SLOPE UTWN H EWMTEE U LNG RIGD COUPU cs I 60" MH �A' 'B' 'C' 'D' 'E' I N� 60n 8" MIN. 65' MIN. 42" MIN. 30" I.D. 6" SIOE OUTLET TEE HORIZONTAL D. DUCTILE IRON MAIN -CORE- DRILLED WITH ROMAC SADDLE NOTES: 11. DATUM SHALL BE CITY OF RENTON, 1988 NAVD. (OR APPROVED EQUAL). SEWER MAIN SEWER MAIN 1. STEPS TO BE POLYPROPYLENE SAFETY STEPS. 12. ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR OTHERWISE STABILIZED TO THE 6" MIN. E. MANHOLE CONNECTION -ALL CONNECTIONS TO MANHOLES SHALL 2. STEPS ARE TO BE IN PUCE BEFORE MANHOLE SECTIONS ARE INSTALLED. CONCRETE BLOCKING ANCLL BE AT MANUFACTURED KNOCK -OUTS OR THE 3. CASTING SHALL BE PER STD. PLAN 401. SATISFACTION OF THE DEPARTMENT FOR THE PREVENTION OF ON -SITE EROSION AFTER THE COMPLETION OF CONSTRUCTION. OF TEE AT MAIN OVER 25 TYPICAL SIDE SEWER ELEVATION STRUCTURE SHALL BE CORE - DRILLED. 4. MANHOLE SECTIONS TO BE OF REINFORCED PRECAST CONCRETE 5. ALL JOINTS BETWEEN THE CONE, RIDE RINGS, BRICKS AND CASTING SHALL BE GROUTED. 13. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ELEVATION 6. ADJUSTMENT OF THE CASTING TO GRADE SHALL BE ACCOMPLISHED WITH A COMBINATION OF ACCORDANCE WITH SECTION 7 OF THE CURRENT STATE OF WASHINGTON STANDARD NOTE: ADJUSTMENT 2RBOND BRICKS TH I AND OF SHRHIMR I��OH�RITEM SHALL BE STAGGERED TO CREATE A RUNNING SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING UNLESS OTHERWASE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2.5' COVER AT PROPERTY 7. SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR SURFACES, INCLUDING CHANNELING, OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL AS WELL AS PLACEMENT AND LINE OR 3 -5' LOWER THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER. COATED (SEALED) WIN A HIGH SOUDS URETHANE COATING; WASSER MC- AROSHIELD OR COMPACTION OF REQUIRED BEDDING MATERIAL TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF 8. RUBBER GASKETED JOINTS SHALL BE IN CONFORMANCE EWITH ASTM C -443. THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE UNYIELDING BASE. PIPE BEDDING SHALL BE 9. CHANNEL HEIGHT SHALL BE A MINIMUM OF 3/4 OF THE INSIDE DIAMETER OF THE LARGEST PIPE PEA GRAVEL 6" ABOVE AND BELOW THE PIPE. 10. CONNECTIONS TO MANHOLE SHALL BE MADE USING GPK ADAPTOR, KOR -N -SEAL BOOTS OR STANDARD APPROVED EQUAL SIDE SEWER INSTALLATION 11. A UNIMPROVED AREAS, MANHOLES SHALL EXTEND A MINIMUM O A AND A MAXIMUM OF 14. SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVC) RUBBER GASKETED ASTM D 3034, STIR 35, OR DUCTILE IRON CLASS 50. (SEWER MAIN TO PROPERTY L I NE) ABOVE FINISHED GRADE OR MUST HAVE A MINIMUM 2' DIAMETER R CONCRETE RINGS POURED AT GRADE. IN PAVED AREAS, COVER MUST SLOPE IN ALL DIRECTIONS TO MATCH PAVING. 15 FINISHED GRADE. AR IN PAVED HAREA, COVER ENMUSTNSLOPE6INNALL AND DIRECTONS TO I MATCH PAVING. STD. PLAN - 406.1 STD. PLAN - 400.1 S=3 66003 STANDARD SANITARY MANHOLE September 2011 OFFE ENGINEERS L " "L "QF �:,,'� r• ��SURVEYED , �„,,, 5859 NE 8th STREET 11 /12/2012 •5 SCALE CI_TY OF 13932 SOUTHEAST 159TH PLACE D.L. OFFE, P.E. SIERRA HOMES INC. Fle"" RENTON, WASHINGTON 98058 1wu RENTON SEWER PLAN /PROFILE D.L. OFFER, P.E. NwnxG xN PHONE: 425-260-3412 G / S " Z ATNNCH DATUM Planning /Building /Public Works Dept. CONTACT: DARRELL OFFER, P.E. /O..• . NAL NO. REVISION BY DATE APPR Wd'"E'" Y 3 of: 3 ,PmeaTa MRLF. cp,s- 3 (oc�o03 I I I JS�EJW�E R