STA 16+65 \
EXISTING
POWER VAULT
O
� f 4
EXISTING
ST. LIGHT— �
CONC. SIDEWALK --- 1
—�---- -- ------�-- ---- --- _--_� _
-4 7
------- -- f --- -----
EXISTING ( 5)
CONDUIT--+--��00�10
18+ 00 i� i Y 0
16"
w W '" S LINE
CONIC. F j
A no
HOUSER WAY S.
NO PARKING
CONSTRUCTION NOTES:
1 INSTALL NEW CITY STANDARD SERVICE CABINET
WITH BATTERY BACKUP SYSTEM FOR STREET
CONTROL AND TRAFFIC SYSTEM
WITH A PHOTO CELL.
REMOVE EXISTING CONDUIT DURING TRENCH
OPERATION AND INSTALL NEW CONDUIT FROM
POWER VAULT TO SERVICE CABINET.
3
INSTALL NEW TYPE 1 JUNCTION BOX.
1
INSTALL 2" PVC CONDUIT WITH 3—#14 AWG AND
6—#8 AWG CONDUCTORS.
DMJM HARRIS I AECOM
10900 NE 8TH STREET, SUITE 750
BELLEVUE, WASHINGTON 98004
PHONE: (425) 454 5600 FAX- (425) 454-02 0
APPROVED FOR CONSTRUCTION
CITY OF RENTON
SECT
.18 T.23N.
11 �1 MON.
1 WELL
R.5E. W.M.
L?LA1� WwAY CS1$OD
ONE LANE
ROAD, AHEAD
Z4
— — — — --
— BP = ■ - -- - �.�
a
EXISTING
ST. LIGHT
�,. TO REMAIN
ul)-ri 1
1h
1
PLAN
SCALE: 1" = 20'
REMOVE EXISTING STREET LIGHT DURING TRENCH
OPERATION AND RELOCATE AS REQUIRED WITH
STREET CONSTRUCTION IMPROVEMENTS AND
INSTALL PEC ON TOP OF POLE.
+ INSTALL 2" PVC CONDUIT WITH 2—#8 AWG
CONDUCTORS FROM RELOCATED STREET LIGHT TO
JUNCTION BOX FOR STREET LIGHT PLUS 3—#14 AWG
FOR PEC. RELOCATE LIGHT TO STA 18+69, 24.5' L.
EXISTING 2" CONDUIT SERVICE TO EXISTING SERVICE
CABINET AT SHATTUCK AVE. AND S 4TH ST.
SEE DWG TS03 FOR SACRIFICIAL BEAM
ELECTRICAL DETAILS.
DATE
&, I ADDENDUM NO. 3
NO. I REVISION
O
S. 4TH PL. q
� Z
----' SHATTUCK AVE.
22+0❑
SHATTUCK AVE.
�VFttti
CONC. — — — SIGN
SEE DWG TS02 FOR HEIGHT DETECTION WARNING
SYSTEM ELECTRICAL DETAILS.
10 INSTALL 2" PVC CONDUIT WITH 6—#8 AWG FOR
HEIGHT DETECTION WARNING SYSTEM, FLASHING
BEACONS AND UNDER STRUCTURE LIGHTING AND
1—#8 AWG GROUND.
11 INSTALL 2" PVC CONDUIT WITH 4—#8 AWG
(2—#8 POWER TO NORTH HEIGHT DETECTION
WARNING SYSTEM AND 2—#8 AWG TO WARNING
LIGHTS ON BEAM AND RAILROAD STRUCTURE)
AND 1—#8 AWG GROUND.
SU RVEYEU
DESIGNED:
D.BELLUOMINI
DRAWN:
Y.DARMAWAN
CHECKED:
J. KIM
YD ❑ 7/09 APPRCVM-
BY I DATE APPR R.MEYER
SCALE; 1 „ = 20'
ONE NCH
AT FULL SCALE
F NOT ONE NCH
SCALE ACCORDINGLY
VE RMAL- NAWD 1988
HORIZONTAL• NAD 1983/1991
DATU Y
END PROJECT
END CONSTRUCTION
SHATTUCK AVE 22+ 33
12 NOT USED.
13 INSTALL 2" PVC CONDUIT WITH 2—#8 AWG FOR
UNDER STRUCTURE LIGHTING AND WARNING LIGHTS
AND 1—#8 AWG GROUND.
CITY OF
sinRENTON
Public Works Dept.
FED AID NO.: ARRA-0167(044)
RECORD DRAWINGS
SEPTEMBER 2010
BASED ON CONTRACTOR'S
RECORDS
20 0 20 40
I I
SCALE IN FEET
RAINIER AVE S (SR 167) Lm
IMPROVEMENTS PROJECT FIE LDBOOK:
PHASE 1 PAGE.-
SHATTUCK AVE S STORMWATER BYPASS DPAWNG NO:
TRAFFIC SYSTEM AND TS01
WARNING LIGHT SYSTEM ;41 OF: It
Lom"WABl-