Loading...
HomeMy WebLinkAboutR-342644CI] z C, 0 J J m i d J d C..] J U a J a J c� z w z 0 U) Uj Q a= a a_ In z d ill a a J .. a C P a a In 0 -12" LED RED FLASHING WARNING LIGHTS 6"0 HANDHOLE @ NIPPLE LOCATION** 8' MIN. wel1 1 CENTER OVER 10' LANE L W12— 301 CENTER OVER 10' LANE z SEE SG04 FOR DETAILS 1 j" NIPPLE @ SIGN (AS REQUIRED) 1 HSS 16" X 16" X 1/2" 12" LED RED FLASHING WARNING LIGHTS SEE ST05 FOR N EM A 3R TERMINAL CABINET DETAILS w J m z a Ln z w 0 w w Cn _--HANDHOLE SACRIFICIAL BEAM ELEVATION 00 oqo 0 00 o YELLOW — RED T� 8---7 —� I� SOLID STATE FLASHER UNIT r I R EEN Tholil� GREEN LINE N G TYPE B JUNCTION BOX TO FLASHINGFROM 120V 2" PVC CONDUIT BEACONS SOURCE WIRING DIAGRAM LED FLASHING BEACON CONTROL ASSEMBLY * CONTRACTOR TO VERIFY NIPPLE LOCATION, PRIOR TO SIGN STRUCTURE FABRICATION. NO FIELD WELDING & DRILLING SHALL BE PERMITTED. ** HANDHOL❑ IS ONLY REQUIRED IF NIPPLE LOCATION IS GREATER THAN 1'-6" FROM ANOTHER HANDHOLE LOCATION. FOR DETAIL OF HAND HOLE, SEE WSDOT STD. SIGN BRIDGE 10.1—A2-2. NOTES: 1. INSTALL 2—#12 AWG AND 1—#12 AWG GROUND FROM WARNING LIGHT CONDUCTORS IN JUNCTION BOX TO FLASHING CONTACTOR IN NEMA-3R TERMINAL CABINET ON TOP OF BEAM. 2. INSTALL 2—#12 AWG AND 1—#12 AWG GROUND FROM FLASHING CONTACTOR TO 12" LED RED FLASHING WARNING LIGHTS. RECORD DRAWINGS SEPTEMBER 2010 BASED ON CONTRACTOR'S RECORDS B 2-3/4" .111110 MOUNTING 3/4" PLATE FOR SIDE MOUNTING STRUCTURAL COLUMN OR PLATE SECTION A —A 1 /2" 0 STANDARD BOLT C'Al \11KI17M 1 /2" 0 LO WASHER CABLE GU 1/2" 0 NUT SECTION B—B v F__V 1O LOCK NIPPLE O2 NIPPLE O3 NOT USED O4 GASKET AND WASHER O12" LED WARNING LIGHT WITH BACK PLATE O6 MOUNTING PLATE (SEE DETAIL BELOW) DRILL HOLES AND ATTACH MOUNTING SHELF TO PROT TEE WITH (2) — 1 /2" BOL_ LOCK WASHERS AND NUTS POLE PLATE FOR WARNING LIGHTS 7/16" THICK PLATE 0 -LAT WASHER 1-1/2" NIPS PIPE THREAD FRUCTURAL )LUM N OR -ATE 12" LED WARNING LIGHT MOUNTING DETAIL q„ 9„ MOUNTING SHELF FOR WARNING LIGHTS ATTACHED TO PROTECTIVE TEE ON BRIDGE (PLATE, NUTS AND BOLTS ARE GALVANIZED) 12" LED WARNING LIGHT WITH STANDARD VISOR AND 5" BACKPLATE S" RAINIER AVE S (SR 167) APPROVED FOR CONSTRUCTION 5�. SAL_ Nm 19M IMPROVEMENTS PROJECT N DMJM HARRIS AECOM DESIGUED N.T.S. HORIZONTAL NAD 1983/1991 BOOK o.BELLUDMINI CITY OF PHASE 1 PAGE; 109M NE 8TH STREET, SURE 750 D Y.aARMAWAN apTU Y � RENTON SHATTUCK AVE S STORMWATER BYPASS BELLEVUE, WASHINGTON 98004 ONE C PH�hIE: (425) 454 FAX: (425) 454-02 a CHECKED: im NCH SACRIFICIAL BEAM, CITY OF RENTON DATE AT Fug SCALE Public Works wept. �.� N APND00R a' FED AID NO.: ARRA-0167(044) LED FLASHING BEACON CONTROL ASSEMBLY 43 48 NO. REVISION BY 1 DATE 1, APPR R.MEYER An"UNMH