Loading...
HomeMy WebLinkAboutT-164104CONSTRUCTION NOTES O1 IN8TALL STREET LIGHTING CABINET FOUNDATION AT STA 6 +10, 35 FT. LT, INSTALL 09 CONNECT NEW CONDUCTORS TO EXISTING ILLUMINATION CONTACTOR CABINET. (SEE DETAIL SHEET 4 -11). CIRCUIT. O ROUTE CONDUIT AND CONDUCTORS TO EXISTING POWER VAULT AND PR3VIDE FOR POWER CONNECTION IN ACCORDANCE WITH UTILITY REQUIREMENTS. O3 INSTALL LUMINAIRE POLE FOUNDATION WITH CONCRETE PAD AND TYPE 1 JUNCTION BOX (SEE DETAIL SHEET 4 -5). INSTALL 30 FT. LIGHTING STANDARD WITH 150 WATT HIGH - PRESSURE SODIUM VAPOR LUMINAIRE. O4 INSTALL LUMINAIRE POLE FOUNDATION WITH CONCRETE PAD AND TYPE 1 JUNCTION BOX (SEE DETAIL 4 -5). (NOTE POLE AND LUMINAIRE TO BE INSTALLED BY OTHERS). OS INSTALL TYPE 1 JUNCTION BOX. O6 INSTALL 10 FT. OF CONDUIT FOR FUTURE USE. INSTALL CAP. C7% DISCONNECT EXISTING LIGHTING CIRCUIT IN JUNCTION BOX AT NORTHEAST CORNER OF SW 7TH STREET AT NACHES AVENUE SW (LOCATION TO BE DESIGNATED BY CITY OF RENTON INSPECTOR). O CONNECT EXISTING LIGHTING CIRCUIT TO NEW CONDUCTORS. SERVICE CABINET TYPE III SINGLE PHASE 120/240 VOLT GROUNDED NEUTRAL BREAKER AND CONTACTOR SCHEDULE CIRCUIT N0. MAIN BREAKER AMPS BRANCH BREAKER AMPS CONTACTOR AMPS REMARKS MAIN 100 3 NO. 2 2" 150 WATT A -1 26.3' RT. 20 30 240 VOLT A -2 - 20 30 240 VOLT TYPE 1 JUNCTION ,BOX WITH PAD AND Z4 A -2 FUTURE LUMINAIRE. 3542C WIRE NOTES RUN CONDUCTORS CONDUIT CL OF POLE TO CL OF ROAD ARM LENGTH MOUNTING HEIGHT Z 3 NO. 2 2" 150 WATT STA 7 +29 26.3' RT. 8 FT. 4 NO. 8 2" 3541C LUMINAIRE. 3 \ 4 NO. 8 TYPE 1 JUNCTION ,BOX WITH PAD AND Z4 A -2 FUTURE LUMINAIRE. 3542C 2 NO. 8 STA 10 +55 23,3' RT, 2 N0. 8 (EXIST) 1 -1/2" (EXIST) �6 2. N0. 8 (NEW> EMPTY 1 -1/2" NOTE: LATERAL CONDUITS SHALL BE PVC SCH 40. STREET CROSSING CONDUITS SHALL BE PVC SCH 80. EX: GENERAL NOTES 1. CONTRACTOR SHALL NOTIFY ALL UTILITIES LOCATED WITHIN PROJECT LIMITS 48 HOURS PRIOR TO COMMENCING WORK. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING UTILITIES. CONTRACTOR SHALL NOTIFY THE AFFECTED UTILITY AND THE CITY OF RENTON IMMEDIATELY UPON DAMAGE. 3. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH CITY OF RENTON DESIGN STANDARDS AND SUPPLEMENTAL SPECIFICATIONS. 4. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL TRAFFIC CONTROL REQUIREMENTS PER CITY OF RENTON POLICY DATED 12/15/88. S. NO BOX, PAD, POLE, OR CABINET SHALL BE PLACED IN THE SIDEWALK. v POWELL AVE. S.Wa LUMINAIRE SCHEDULE LUMINAIRE N0. LAMP WATTAGE POLE LOCATION CL OF POLE TO CL OF ROAD ARM LENGTH MOUNTING HEIGHT CIRCUIT N0. REMARKS 3540C 150 WATT STA 7 +29 26.3' RT. 8 FT. 30 FT. A -2 3541C LUMINAIRE. STA 8 +80 (2) 25.3' LT. TYPE 1 JUNCTION ,BOX WITH PAD AND A -2 FUTURE LUMINAIRE. 3542C 150 WATT STA 10 +55 23,3' RT, 8 FT. 30 FT. A -2 CITY OF RENTON 3000C 150 WATT STA 0+65-1 37' LT. 3001C 150 WATT STA 2 +15 33.5' RT. 3002C 150 WATT STA 3 +65 33.5' LT. 3003C ISO STA 5 +15 32.8' RT. 1912C STA 6 +24 29.6'LT I A -1 A -1 SEE "NACHES 4 -1 AVENUE SW A -1 ILLUMINATION PLAN SHEET 2. A -1 EXIST. FOUNDATION - FUTURE LUMINAIRE. :`O AP ?,OVAIL .................. .... �® NAGHES _ S e AVE' 12 LEGEND ® LIGHTING CONTACTOR. CABINET. COMBINATION FOUNDATION WITH LUMINAIRE. COMBINATION FOUNDATION WITHOUT ® LUMINAIRE. ® TYPE 1 JUNCTION ,BOX WITH PAD AND GALVANIZED LID. - - - CONDUIT. ILLUMINATION PLAN CITY OF RENTON wa