Loading...
HomeMy WebLinkAboutT-172202W Z — ■1 will OP77CALL Y PROGRAMMED O �¢" Q ez' O ►ap r WT o OW_ Oar Obr Olfm r G N A L .H EAOt) ON + A4 ( �••- A,,,6 4 PAa t'f> VNAd -14. ftor-TKIAW zt) i ! HA,5F— P radRAAN C� i9 \ i \AT- �11 8 0 X11 �1 1 11� 1 11 I! 11 1 1 GVk �1 1 \ .2 — —r BOG 11 INSTALL 6' X 6" ' VEHICLE DETBCTjOA LOOP "i SEE SPECIAL PROVISIONS, DETAIL SHEET AND STANDARD PLAN J -21B. 12 INSTALL CONTROLLER ON EXISTING FOUNDATION AND CONNECT FIELD WIRES TO APPROPRIATE TERMINALS. SEE SPECIAL PROVISIONS AND STANDARD PLAN J -18A. 13 STREET LIGHT POLELUMINAIRE AND JUNCTION BOX TO BE INSTALLED BY OTHERS. 14 INTERCONNECT AND /OR STREET LIGHT CIRCUIT TO BE INSTALLED BY OTHERS. SEE SPECIAL PROVISIONS. 15 PROVIDE AND INSTALL JUCTION BOX TYPE III. INSTALL TYPE A SERVICE. SEE SPECIAL PROVISIONS, DETAIL SHEET AND STANDARD PLAN J -20. 16 PROVIDE AND INSTALL JUNCTION BOX TYPE IV. SPLICE STREET LIGHT G CIRCUIT. SEE SPECIAL PROVISIONS AND DETAIL SHEET. washington ENGINEERS ARCHITECTS PLANNERS SURVEYOR /^� R? . CONSTRUCTION NOTES 0 v PROVIDE GALVANIZED STEEL SIGNAL POLE TYPE B -D -2 WITH 30' MAST A" POLE WILL BE UTILIZED BY CITY. INSTALL POLE TYPE D -D -2 SUPPLT7D BY CITY AT STATION -0 +61 LT, 41 FROM THE ISLAND CURBLINE; INSTALL 3 TEHICLE SIGNAL HEADS MTG TYPE L; 1 PEDESTRIAN SIGANL HEAD MTG TYP7 B: AND 1 PEDESTRIAN PUSH BUTTON. INSTALL 400 WATT SODIUM VAPOR LUMINAIRE. CONNECT FIELD WIRES TO TIIE APPROPRIATE TERMINALS. S 7 SPECIAL PROVISIONS, DETAIL SHEET AND STANDARD PLAN J -21C. OPROVIDE AND INSTALL GALVANIZED STEEL SIGNAL POLE TYPE C -T -3 WITH 351 MAST ARM AT STATION 42+67 LT, 6.01 FROM THE ISLAND CURBLINE; INSTALL 3 VEHICLE SIGNAL HEADS MTG TYPE L; AND 1 VEHICLE SIGNAL HEAD MTG TYPE K. INSTALL 400 WATT SODIUM VAPOR LUMINAIRE. CONNECT FIELD WIRES TO THE APPROPRIATE- TERMINALS. SEE SPECIAL_PROVISION, DETAIL SHEET AND STANDARD PLAN J -21C. [ 3.1 PROVIDE AND INSTALL GALVANIZED STEEL SIGNAL POLE TYPE D -2 WITH 40' `J MAST ARM AT STATION 00 +47 RT, 3.0' FROM THE ISLAND CURBLINE; INSTALL . 3 VEHICLE SIGNAL HEADS MTG TYPE L: 2 PEDESTRIAN SIGNAL HEADS MTG TYPE A; AND 2 PEDESTRIAN PUSH BUTTONS. CONNECT FIELD WIRES TO THT1 APPROPRIATE TERMINALS. SEE SPECIAL PROVISONS, DETAIL SHEET AND STANDARD PLAN J -21C. OPROVIDE AND-INSTALL GALVANIZED STEEL LUMINAIRE POLE TYPE E -T -1 WITH TWIN 8' LUMINAIRE ARMS AT STATION 41+61 LT, 2.51 FROM THE ISLAND CURBLINE; INSTALL 1 VEHICLE SIGNAL HEAD MTG TYPE K. INSTALL 2 -4no WATT SODIUM VAPOR LUMINAIRES. CONNECT FIELD WIRES TO THE APPROPRIATE TERMINALS. SEE SPECIAL PROVISIONS, DETAIL SHEET AND STANDARD PLAN J -21C. OPROVIDE AND INSTALL GALVANIZED STEEL SIGNAL POLE TYPE A -1 WITH 251 MAST ARM AT STATION 41 +92 LT 6.01 FROM THE ISLAND CURBLINE; INSTALL 2 VEHICLE SIGNAL HEADS MTG TYPE L; 1 PEDESTRIAN SIGNAL HEAD MTG TYPE B; AND 1 PEDESTRIAN PUSH BUTTON. CONNECT FIELD WIRES TO THE APPROPRIATE TERMINALS. SEE SPECIAL PROVISIONS, DETAIL SHEET AND STANDARD PLAN J -21C. ( 6.) PROVIDE AND INSTALL 8' GALVANIZED STEEL PEDESTAL POLE TYPE I -B AT STATION 42+62 RT, 2.51 FROM THE ISLAND CURBLINE. INSTALL 2 PEDESTRIAN SIGNAL HEADS MTG TYPE A,AND 2 P- DESTRIAN PUSH BUTTONS. SEE SPECIAL PROVISIONS, DETAIL SHEET AND STANDARD PLANS J -21C AND J -21D. OPROVIDE AND INSTALL JUNCTION BOX TYPE I, DESIGN B. SEE SPECIAL PROVISIONS AND STANDARD PLAN J -19. OPROVIDE AND INSTALL JUNCTION BOX TYPE IV. SEE SPECIAL PROVISIONS AND DETAIL SHEET. OPROVIDE AND INSTALL. JUNCTION BOX TYPE III. SEE SPECIAL PROVISIONS AND STANDARD PLAN J -20. OINSTALL 61X 40' VEHICLE DETECTION LOOP. SEE SP °CT L =? 17T ^•T(WS DETAIL SHEET AND STANDARD PLAN J= -21B. 'v is CITY OF RENTON •� ENGINEERING DEPARTMENT F; +rt i; S.W. GRADY WAY AI) RAINIER AVE. SOUTH yss /pNA��,��G�.�' TRAFFIC SIGNAL INSTALLATION mm 11177"Tl ■ /^� R? . CONSTRUCTION NOTES 0 v PROVIDE GALVANIZED STEEL SIGNAL POLE TYPE B -D -2 WITH 30' MAST A" POLE WILL BE UTILIZED BY CITY. INSTALL POLE TYPE D -D -2 SUPPLT7D BY CITY AT STATION -0 +61 LT, 41 FROM THE ISLAND CURBLINE; INSTALL 3 TEHICLE SIGNAL HEADS MTG TYPE L; 1 PEDESTRIAN SIGANL HEAD MTG TYP7 B: AND 1 PEDESTRIAN PUSH BUTTON. INSTALL 400 WATT SODIUM VAPOR LUMINAIRE. CONNECT FIELD WIRES TO TIIE APPROPRIATE TERMINALS. S 7 SPECIAL PROVISIONS, DETAIL SHEET AND STANDARD PLAN J -21C. OPROVIDE AND INSTALL GALVANIZED STEEL SIGNAL POLE TYPE C -T -3 WITH 351 MAST ARM AT STATION 42+67 LT, 6.01 FROM THE ISLAND CURBLINE; INSTALL 3 VEHICLE SIGNAL HEADS MTG TYPE L; AND 1 VEHICLE SIGNAL HEAD MTG TYPE K. INSTALL 400 WATT SODIUM VAPOR LUMINAIRE. CONNECT FIELD WIRES TO THE APPROPRIATE- TERMINALS. SEE SPECIAL_PROVISION, DETAIL SHEET AND STANDARD PLAN J -21C. [ 3.1 PROVIDE AND INSTALL GALVANIZED STEEL SIGNAL POLE TYPE D -2 WITH 40' `J MAST ARM AT STATION 00 +47 RT, 3.0' FROM THE ISLAND CURBLINE; INSTALL . 3 VEHICLE SIGNAL HEADS MTG TYPE L: 2 PEDESTRIAN SIGNAL HEADS MTG TYPE A; AND 2 PEDESTRIAN PUSH BUTTONS. CONNECT FIELD WIRES TO THT1 APPROPRIATE TERMINALS. SEE SPECIAL PROVISONS, DETAIL SHEET AND STANDARD PLAN J -21C. OPROVIDE AND-INSTALL GALVANIZED STEEL LUMINAIRE POLE TYPE E -T -1 WITH TWIN 8' LUMINAIRE ARMS AT STATION 41+61 LT, 2.51 FROM THE ISLAND CURBLINE; INSTALL 1 VEHICLE SIGNAL HEAD MTG TYPE K. INSTALL 2 -4no WATT SODIUM VAPOR LUMINAIRES. CONNECT FIELD WIRES TO THE APPROPRIATE TERMINALS. SEE SPECIAL PROVISIONS, DETAIL SHEET AND STANDARD PLAN J -21C. OPROVIDE AND INSTALL GALVANIZED STEEL SIGNAL POLE TYPE A -1 WITH 251 MAST ARM AT STATION 41 +92 LT 6.01 FROM THE ISLAND CURBLINE; INSTALL 2 VEHICLE SIGNAL HEADS MTG TYPE L; 1 PEDESTRIAN SIGNAL HEAD MTG TYPE B; AND 1 PEDESTRIAN PUSH BUTTON. CONNECT FIELD WIRES TO THE APPROPRIATE TERMINALS. SEE SPECIAL PROVISIONS, DETAIL SHEET AND STANDARD PLAN J -21C. ( 6.) PROVIDE AND INSTALL 8' GALVANIZED STEEL PEDESTAL POLE TYPE I -B AT STATION 42+62 RT, 2.51 FROM THE ISLAND CURBLINE. INSTALL 2 PEDESTRIAN SIGNAL HEADS MTG TYPE A,AND 2 P- DESTRIAN PUSH BUTTONS. SEE SPECIAL PROVISIONS, DETAIL SHEET AND STANDARD PLANS J -21C AND J -21D. OPROVIDE AND INSTALL JUNCTION BOX TYPE I, DESIGN B. SEE SPECIAL PROVISIONS AND STANDARD PLAN J -19. OPROVIDE AND INSTALL JUNCTION BOX TYPE IV. SEE SPECIAL PROVISIONS AND DETAIL SHEET. OPROVIDE AND INSTALL. JUNCTION BOX TYPE III. SEE SPECIAL PROVISIONS AND STANDARD PLAN J -20. OINSTALL 61X 40' VEHICLE DETECTION LOOP. SEE SP °CT L =? 17T ^•T(WS DETAIL SHEET AND STANDARD PLAN J= -21B. 'v is CITY OF RENTON •� ENGINEERING DEPARTMENT F; +rt i; S.W. GRADY WAY AI) RAINIER AVE. SOUTH yss /pNA��,��G�.�' TRAFFIC SIGNAL INSTALLATION mm 11177"Tl ■