Loading...
HomeMy WebLinkAboutT-186401C'N I o z, so W z W z W Q ! I 2 3 4 5 6 7 8 9 z O z �'L L NE )j"!1i1's e I 0 +00 J1 +00 2 +00 NE 4TH STREET LEGEND W W� FN r z � X U W OCONDUIT X— LUMINAIRE AND POLE IR ® JUNCTION BOX 35478 CITY OF RENTON POLE DECAL NO. (TYP.) INSTALL AS DETAILED HEREON 5TH STREET -tart a t�. 3 +00 4 +00 CONSTRUCTION NOTES ORemove existing WYE SPLICE connection at junction box. He— splice Luminaire 11915 B to power source lead wires with an INLINE SPLICE. ORemove existing wire run. OInstall WSOOT Type I Junction Box (See Std. Plan JAM), pole foundation, and pad at Station 4 +75. Relocate existing luminaire ( 11916 B) from Station 5 +65 to Station 4 +71. Splice into circuit 12 from illumination system to the east of Heritage Forest Apartments. Cap photoelectric cell. ORemove Existing luminaire (;«1916 B), junction box and pad. OInstall new flat lens cobra head i5OW HPS, 240V, medium cutoff III Distribution on 35' Davit Pole with 6' arm. Also install WSOOT Type I Junction Box (See Std. Plan d —ila) and pad foundation. Splice into circuit 12 from illumination system to the east of Heritage Forest Apartments, OInstall new conduit (PVC ;Schedule 80) across roadway by sawcut and trend) method WIRE SCHEDULE �! 2 18 AWG (USE —XLP) in existing 1.5' conduit 1.5' conduit (Schedule 40), 2 #B AWG (USE —XLP) 1.5' Conduit (Schedule 40), 2 #8 AW6 (USE —XLP), 118 Bare Ground 1.5' Conduit (Schedule 80), 2 #B AWG (USE —XLP) T1 1.5' Conduit, 2 #8, 1 Ito Ground (existing) (1) Bremerton Ave NE illumination (2) NE 5th St illumination GENERAL NOTES L All work shall be in accordance with the City of Renton Standard Specifications and these plans. 2. The locations of features shown are approximate and shall be verified in the field by the contractor, as necessary. 3. Install all street lighting materials shown an the plans, except as noted. All materials shall be new and of the best available grade or quality, except as noted. 4. The contractor shall submit a request to the City of Renton for materials approval at the earliest possible date. 5. All work shall he consistent with utility agency requirements. The contractor shall contact all pertinent utility agencies 48 hours before commencing work, and shall coordinate the work with the utilities throughout the project. 6. The contractor shall be responsible for any damage to existing utilities. The contractor shall notify the affected utility company and the City immediately upon damage. 7. The contractor shall notify the City of Renton Traffic Engineering Division (235 -2620) for inspection purposes, 24 hours before commencing work. No work shall be covered until it has been examined by the engineer. B. Existing Contactor Cabinet for the lighting system to the east of Heritage Forest Apartments is located on west side of Bremerton Ave NE 200' south of NE 5th St. 9. Existing power source for lighting system to the west of Heritage Forest Apartments is located an NE 5th St at Station 2 +t5. 10. All conduit shall be PVC Schedule 40 unless noted otherwise. /?(o4 CITY OF R'ENTON D E P A R T M E N T OF PUBLIC WO R K S v , 11 3 n �,le G 1 Projoct: HERITAGE FOREST WM E POPP ABBOCIATE8 r - -" - -- TgAN�POATATION •CIVIL ■NOIN��gs ' _ r BELLEVUE WASHINGTON - NO. REVISION VICINITY MAP L5 +00 6 +00 /� T / z y9 LUMINAIRE SCHEDULE Luminaire Pole Mounting Arm Circuit Comment No Location Height Length No 1913 B i +10 25' 6' 1 (1) 1914 8 2 +20 25' 8' 1 (1) 1915 8 3 +50 25' 6' 1 (i) 1916 B 5 +65 25' B' 1 (2) 1916 B 4+71 25' B' A -2 (3) 3387 C 12 +66 35' 6' A -2 (4) 3388 C ii +08 35' 6' A -2 (4) 3389 C 9+50 35' 6' A -2 (4) 3390 C 7+92 35' 6' A -2 (4) 3547 C 6+34 35' 6' A -2 (5) (1) Existing PSPL circuit. (2) Existing PSPL circuit, Pole to be relocated and disconnected from existing circuit. (3) Existing City of Renton circuit, Existing pole to be relocated'and connected to this circuit. (4) Existing City of Renton circuit and pole. Poles 3387-3389 are flat shown. Station points are referenced from Union Ave NE. (5) Existing City of Renton circuit with new pole. BREMERTON AVE CONTACTOR CABINET Service 6 Main Brkr. Branch Brkr Contactor Comment Circuit No. Amps Amps Amps Service 100 — — — A -1 240V — 30 30 (1) A -2 240V — 30 30 (2) (1) Bremerton Ave NE illumination (2) NE 5th St illumination GENERAL NOTES L All work shall be in accordance with the City of Renton Standard Specifications and these plans. 2. The locations of features shown are approximate and shall be verified in the field by the contractor, as necessary. 3. Install all street lighting materials shown an the plans, except as noted. All materials shall be new and of the best available grade or quality, except as noted. 4. The contractor shall submit a request to the City of Renton for materials approval at the earliest possible date. 5. All work shall he consistent with utility agency requirements. The contractor shall contact all pertinent utility agencies 48 hours before commencing work, and shall coordinate the work with the utilities throughout the project. 6. The contractor shall be responsible for any damage to existing utilities. The contractor shall notify the affected utility company and the City immediately upon damage. 7. The contractor shall notify the City of Renton Traffic Engineering Division (235 -2620) for inspection purposes, 24 hours before commencing work. No work shall be covered until it has been examined by the engineer. B. Existing Contactor Cabinet for the lighting system to the east of Heritage Forest Apartments is located on west side of Bremerton Ave NE 200' south of NE 5th St. 9. Existing power source for lighting system to the west of Heritage Forest Apartments is located an NE 5th St at Station 2 +t5. 10. All conduit shall be PVC Schedule 40 unless noted otherwise. /?(o4 CITY OF R'ENTON D E P A R T M E N T OF PUBLIC WO R K S v , 11 3 n �,le G 1 Projoct: HERITAGE FOREST WM E POPP ABBOCIATE8 r - -" - -- TgAN�POATATION •CIVIL ■NOIN��gs ' _ r BELLEVUE WASHINGTON - NO. REVISION VICINITY MAP