HomeMy WebLinkAboutT-2020021/4" LOAD LINE Ir4"
I /8e, Ifa"
FUSE CUTTING RINGS
LENGTH = 4 7/8"
DIAMETER= 7/8"
FUSE KIT
EPDXY FILL
INLINE SPLICE WYE SPLICE
SPLICE KIT
LETTER SUFIXED LETTER PREFIXED
CITY OWNED PUGET POWER OWNED
1�
N i
CURB N
—E 11
+ `F DECAL -
r� REFLECTORIZED 601M
Z 45° GOLD OR WHITE LEGEND
ON BLACK BACKGRODID
Z
o TRAFFIC
0 00 FLOW
PLAN VIEW
�9
5/18" GALV STEEL
COVER PLATE
(DIAMOND PATTERN)
1
,-MV. STEEL FRAME ANCHORED IN PLACE
(DIAMOND PATTERN)
"D d
SECTION A-A SECTION B -B
m\
JUNCTION BOX -TYPE I
STREET LIGHT STANDARD
DECAL NUMBERING SYSTEM
A M
C A BOX TYPE
R ITEM TYPE 1 I TYPE 2
1 I K ALTERNATE A ALTERNATE BI
C BOX..IOUTSID WIDTH LENGTH B 22 22
19. 28••
B BOX OUTSIDE WIDTH 17 17.. V2"
L D BOX INSIDE WIDTH 13" 19" 17"
ABERDEEN AVE_ NE m E LID LENGTH IE IE 261/27
3 4 5 6 7 E F LID WIDTH 13" 18 17"
G BOX DEPTH i2 127' 12"
--- • -t H LID FRAME DEPTH 5/16" SAG" 5/167
J WALL THICKNESS (MIN) - 1 1/2 °. 1 1/2 " 1 1/2"
K WIRE REINFORCEMENT W-3 W -2.5 W-2.5
PLAN VIEW - L LEGEND SEE DFi AIL SEE DETAIL SEE DETAIL
_T■ JUNCTION BOX DIMENSION TABLE
K ITEM MATERIAL
- BOX 600 PSI CONCRETE (SEE NOTES)
_ FRAME DIAMOND PLATE STEEL
8 LID SUPPORT V C.L. 8" MIN. THICK STEEL OR T -A36
'
LID DIAMOND PLATE STEEL
ANCHORS STEEL WIRE OR TEE PLATE
v~i ELEVATION. VIEW REINFORCEMENT ASTM A-82 STEEL
= z 6" MIN -8"MAX MATERIAL TABLE
~ 2 I" NOM
N ABERDEEN PL. NE T S T SIGNALS
g i►I 3 'MAX
W 7 TRAFFIC SIGNAL ILLUMINATION LIGHTING
z �2" MAX SYSTEM LEGEND SYSTEM LEGEND TS -LT
12 6 "GRAVEL PAD NOTE= FORM LETTERS WITH
(COMPACTED) 1/8" WELD BEAD. GRIND OFF TELEMETRY
i DIAMOND PATTERN BEFORE
II FORMING LETTERS.
TYPICAL. JUNCTION BOX LEGEND DETAIL
INSTALLATION DETAILS
I
LID NOTE :2 HOOKS
PER LIDS:
STREET LIGHTING CIRCUIT DIAGRAM [I��XI "X3 /18" FLG.1
HOOK DETAIL
JUNCTION BOX DETAILS
NIRE LO
2" W.P.S. SLIPFITTER
EVACKET C413LE 2
OP Z5c 314' REDUCING W"EK
51N6LE OR DOUBLE
MAST AtzM AS
tZEQ�� \ -/
\ 3/4" t�
\ \� / PW -POUI3LE MAST
AIZM . I145TALL 2 "°
MAST AI2M (QAOLE BETWEEN
WIRING t7lZM LUMINAI12E5 WIZEN 3/4, RoMEX comtNECCO(Z
BOTU LUM I NAI IZES LOCK1 or
A� E ON SAME
STRAIN RELIEF DETW L
NOTES=
ALL DIMENSIONS ARE_ EXACT CONFIGURATIONS VARY
AMONG DIFFERENT MANUFACTURERS
THE NOTED LID THICKENERS OVERALL MINIMUM_ THE
DIAMOND PATTERN FOR TYPE OR TYPE 2 BOXES SHALL
BE 28% MINIMUM OF OVERALL THICKNESS.
LID SUPPORT MEMBERS SHALL BE WELDED TO THE FRAME.
4000 PSI CONCRETE IS ALLOWED IF BOX REINFORCEMENT
CONSISTS OF 6X6 - W3XW3 WELDED WIRE FABRIC
WELDED TO THE FRAME.
WHEN NOTED IN THE CONTRACT, TYPE 2 AND TYPE 3
BOXES SHALL BE PROVIDED WITH 10 DEEP EXTENSION
BOXES
WHEN NOTED IN THE CONTRACT, TYPE 2 BOXES SHALL
BE PROVIDED WITH A 10 X 27 1/2" 10 GAGE DIVIDER
PLATE COMPLETE FASTENERS.
NON-CONCRETE BOXES MAY BE SUBMITTED FOR
APPROVAL. EVALUATION WILL INCLUDE AN H -20 LOAD
TEST.
t
e
%P-
RECOMMENDED
I
INSTALL DECAL
NUMBERS TO BE
NUMBERS VERTICALLY
2' TO 2 1 /2"' IN
� BY 11tf>H
HEIGHT, INSTALLED
ONLY IN DRY
WEATHER 50°
OR ABOVE
NUMBERING EXAMPLES
LETTER SUFIXED LETTER PREFIXED
CITY OWNED PUGET POWER OWNED
1�
N i
CURB N
—E 11
+ `F DECAL -
r� REFLECTORIZED 601M
Z 45° GOLD OR WHITE LEGEND
ON BLACK BACKGRODID
Z
o TRAFFIC
0 00 FLOW
PLAN VIEW
�9
5/18" GALV STEEL
COVER PLATE
(DIAMOND PATTERN)
1
,-MV. STEEL FRAME ANCHORED IN PLACE
(DIAMOND PATTERN)
"D d
SECTION A-A SECTION B -B
m\
JUNCTION BOX -TYPE I
STREET LIGHT STANDARD
DECAL NUMBERING SYSTEM
A M
C A BOX TYPE
R ITEM TYPE 1 I TYPE 2
1 I K ALTERNATE A ALTERNATE BI
C BOX..IOUTSID WIDTH LENGTH B 22 22
19. 28••
B BOX OUTSIDE WIDTH 17 17.. V2"
L D BOX INSIDE WIDTH 13" 19" 17"
ABERDEEN AVE_ NE m E LID LENGTH IE IE 261/27
3 4 5 6 7 E F LID WIDTH 13" 18 17"
G BOX DEPTH i2 127' 12"
--- • -t H LID FRAME DEPTH 5/16" SAG" 5/167
J WALL THICKNESS (MIN) - 1 1/2 °. 1 1/2 " 1 1/2"
K WIRE REINFORCEMENT W-3 W -2.5 W-2.5
PLAN VIEW - L LEGEND SEE DFi AIL SEE DETAIL SEE DETAIL
_T■ JUNCTION BOX DIMENSION TABLE
K ITEM MATERIAL
- BOX 600 PSI CONCRETE (SEE NOTES)
_ FRAME DIAMOND PLATE STEEL
8 LID SUPPORT V C.L. 8" MIN. THICK STEEL OR T -A36
'
LID DIAMOND PLATE STEEL
ANCHORS STEEL WIRE OR TEE PLATE
v~i ELEVATION. VIEW REINFORCEMENT ASTM A-82 STEEL
= z 6" MIN -8"MAX MATERIAL TABLE
~ 2 I" NOM
N ABERDEEN PL. NE T S T SIGNALS
g i►I 3 'MAX
W 7 TRAFFIC SIGNAL ILLUMINATION LIGHTING
z �2" MAX SYSTEM LEGEND SYSTEM LEGEND TS -LT
12 6 "GRAVEL PAD NOTE= FORM LETTERS WITH
(COMPACTED) 1/8" WELD BEAD. GRIND OFF TELEMETRY
i DIAMOND PATTERN BEFORE
II FORMING LETTERS.
TYPICAL. JUNCTION BOX LEGEND DETAIL
INSTALLATION DETAILS
I
LID NOTE :2 HOOKS
PER LIDS:
STREET LIGHTING CIRCUIT DIAGRAM [I��XI "X3 /18" FLG.1
HOOK DETAIL
JUNCTION BOX DETAILS
NIRE LO
2" W.P.S. SLIPFITTER
EVACKET C413LE 2
OP Z5c 314' REDUCING W"EK
51N6LE OR DOUBLE
MAST AtzM AS
tZEQ�� \ -/
\ 3/4" t�
\ \� / PW -POUI3LE MAST
AIZM . I145TALL 2 "°
MAST AI2M (QAOLE BETWEEN
WIRING t7lZM LUMINAI12E5 WIZEN 3/4, RoMEX comtNECCO(Z
BOTU LUM I NAI IZES LOCK1 or
A� E ON SAME
STRAIN RELIEF DETW L
NOTES=
ALL DIMENSIONS ARE_ EXACT CONFIGURATIONS VARY
AMONG DIFFERENT MANUFACTURERS
THE NOTED LID THICKENERS OVERALL MINIMUM_ THE
DIAMOND PATTERN FOR TYPE OR TYPE 2 BOXES SHALL
BE 28% MINIMUM OF OVERALL THICKNESS.
LID SUPPORT MEMBERS SHALL BE WELDED TO THE FRAME.
4000 PSI CONCRETE IS ALLOWED IF BOX REINFORCEMENT
CONSISTS OF 6X6 - W3XW3 WELDED WIRE FABRIC
WELDED TO THE FRAME.
WHEN NOTED IN THE CONTRACT, TYPE 2 AND TYPE 3
BOXES SHALL BE PROVIDED WITH 10 DEEP EXTENSION
BOXES
WHEN NOTED IN THE CONTRACT, TYPE 2 BOXES SHALL
BE PROVIDED WITH A 10 X 27 1/2" 10 GAGE DIVIDER
PLATE COMPLETE FASTENERS.
NON-CONCRETE BOXES MAY BE SUBMITTED FOR
APPROVAL. EVALUATION WILL INCLUDE AN H -20 LOAD
TEST.
t
e
%P-
RECOMMENDED
RECOMMENDED
FOR APPROVAL
FOR APPROVAL
BY c �. �7 e�
� BY 11tf>H
9"
T?O —4 ( -20Z0 + I I
I I I I I I I& I I I I I I I I I& I I 1 1 1 A I I I AL I I I Ilk I� I I 1 I �I