Loading...
HomeMy WebLinkAboutT-202201EXISTING 4' CONIC. SIDEWALK STA. 52 +97.71 CL N.E. 12TH STREET -- y l GAS LINE Al Z > I °a o ( 1 g Ll 0i - EXISTING 3" PVC CONDUIT I FOR CITY OF RENTON TELEMETRY LINES. SEE ! I ; NOTE 11. ( 1 i i �pr Fa PROPERTY LINE - w I i a "C WITH 1 NEW 7'IC (NC. I NYLON PULL STRING SIDEWALK i PHOTOk I ON LU IN RE J I 3 31 I auC,3'r1,a*&, IIj 1/2" GAS INE 3012 `. III I ql ja „c 301, 2-8 EXISTING PHONE MPANY TERMINAL BOX 1 I TO BE RELOCATED BEHIND SIDEWALK. 2” GAS ( j f/o i%r✓ /e LINE Fjeode i UTILITY POLE 0 BE RELOCATED BEHIND SIDEWALK, SEE NOTE 12. 1 { 120/240 VAC, I SERVICE FROM TRANSFORMER LOCATED ON POLE. i 3 LEGEND: H.P.S. LUMINAIRE. FOR SPECIFICS SEE LUMINAIRE SCHEDULE. PVC CONDUIT - SCHEDULE 40 WITH SCHEDULE 80 UNDER ROADWAYS. Q JUNCTION BOX ® CONTROL CABINET, SEE PANEL SCHEDULE. MH MANHOLE FH FIRE HYDRANT SO STORM DRAIN SS SANITARY SEWER CB CATCH BASIN ! ' i EW DRIVEW Y -� 1 MH I I { EMPTY CONDUITS ` 2 4" DIA. 12" DIA. J MH d7 I VMH 1 LINE C8 I a „C ,# 8 i i WATER D II X l ST € NG 3” PVC {I OR CITY OF RENT I TELEMETRY LINES. i NOTE 1!, r r I 13733 F1 NYLON PULL STRI NEW iii' CONIC. I { S I 0EV 4LK--+----w I I I I � { i 1I}' R?-G14 - 09-44Y j ) i uTiL /TY FA"A4@'A/T ! I i t LIT I L 1 TY POLE TO BE D7-RELOCATED. SEE NOTE 12. INAL PHONE COMPANY TED BEHIND SIDEWALK. PROPERTY LINE EXISTING PUGET POWER 12" SD-J UNDERGROUND J -BOX SITE PLAN — 12TH & MONROEII SCALE: I" = 20' 0 10' 20' 40' 60' 7,41041 -202 2 GRAPHIC SCALE IA I I I 19 18 17 16 _111awl-ax—I _40w DIAMETER = 7/8" LOAD LINE '/4 I/8" I/8" FUSE CUTTING RINGS FUSE KIT EPDXY FILL EPDXY FILL ' INLINE SPLICE WYE SPLICE SPLICE KIT NOTES: QI ALL WORK SHALL BE IN ACCORDANCE WITH THE LATEST CITY OF RENTON STANDARD SPECIFICATION AND THESE PLANS, Q2 THIS SITE PLAN IS DIAGRAMMATIC AND IS INTENDED TO SHOW FEATURES OF THE INSTALLATION, AND NOT EXACT FEATURES OF THE SITE. CONTRACTOR SHALL FIELD VERIFY FEATURES AS NECESSARY. COORDINATE ANY DISCREPANCIES BETWEEN THE DRAWING AND THE FIELD WITH THE OWNER AND /OR HIS REPRESENTATIVE. Q3 THE CONTRACTOR SHALL SUBMIT A REQUEST TO THE CITY OF RENTON FOR MATERIALS APPROVAL AT THE EARLIEST POSSIBLE DATE. ® ALL WORK SHALL BE CONSISTANT WITH UTILITY AGENCY REQUIREMENTS, THE CONTRACTOR SHALL CONTACT ALL PERTINENT UTILITY AGENCIES 48 HOURS BEFORE COMMENCING WORK, AND SHALL COORDINATE THE WORK WITH THE UTILITIES THROUGHOUT THE PROJECT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING UTILITIES AND SHALL NOTIFY THE AFFECTED UTILITY COMPANY AND THE CITY OF RENTON IMMEDIATELY UPON DAMAGE. Q THE CONTRACTOR SHALL NOTIFY THE CITY OF RENTON CUSTOMER SERVICE DIVISION ..(277 -5570) FOR INSPECTION PURPOSES, 24 HOURS BEFORE COMMENCING WORK. NO WORK SHALL BE COVERED UNTIL IT HAS BEEN EXAMINED BY THE ENGINEER. © INSTALL ALL STREET LIGHTING MATERIALS SHOWN ON THE PLANS, EXCEPT AS NOTED. ALL MATERIALS SHALL BE NEW AND OF THE BEST AVAILABLE GRADE OR QUALITY, EXCEPT AS NOTED. A I' -2" 2' TO -2' 30' OVERHANG 23' -3" Q7 TESTING OF THE ENTIRE SYSTEM SHALL BE PERFORMED AFTER INSTALLATION. ANY DEFECTS NOTED SHALL BE CORRECTED BEFORE FINAL ACCEPTANCE. WHEN THE LIGHTING SYSTEM HAS BEEN COMPLETELY TESTED AND ALL DEFICIENCIES CORRECTED, . A NOTARIZED BILL OF SALE SHALL BE PROVIDED TO THE CITY. THE CITY SHALL THEN SUPPLY A LETTER OF ACCEPTANCE FOR RELEASE OF BONDAGE ON THE PROJECT. THE BILL OF SALE SHALL BE NOTARIZED AND SHALL INCLUDE THE FOLLOWING: 1) NUMBER OF POLES; 2) NUMBER OF LUMINAIRES; 3) NUMBER OF JUNCTION BOXES; AND 4) STATEMENT IDENTIFYING ALL OTHER NECESSARY APPURTENANCES (WIRE, CONDUIT, ETC...). ® ALL EQUIPMENT FURNISHED SHALL BE GUARANTEED AGAINST COMPONENT FAILURE FOR A PERIOD OF ONE YEAR FOLLOWING ACCEPTANCE FROM THE CITY. Q9 AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR UPON COMPLETION OF THE PROJECT.. QO CONSTRUCTION SHALL BE COORDINATED SUCH THAT EXISTING STREET LIGHTS REMAIN OPERATIONAL DURING DUSK HOURS. II EXISTING SITE INFORMATION WAS OBTAINED FROM HANSEN SURVEYING SHEET I OF I, DATED 3/8/90; AND CITY OF RENTON DRAWING 3B129 SHEETS 9/28 AND 10/28, DATED 11/18/85. 1QPuceT- poweRTO REPI -ACE EXIST!N¢ PawEri POLES WITH TALLER POLES LOCATED BEHIND THE SIDEWALK. COORDINATE STREET LIGHT INSTALLATION WITH PUGET POWER TO INSURE THAT A MINIMUM OF 10 FEET CLEARANCE IS MAINTAINED BETWEEN STREET LIGHTS AND POWER LINES. COSTS OF REQUIRED POLE CHANGES WILL BE PAID TO PUGET POWER BY OWNER. R/W LINE SIDEWALK CURB CL ROADWAY L` rti � Q) I` 0) � tt0 � C E, W O tall W a N F�1 co U O O UZ 'd Cd 41 Cd 46 -02 m N Q W z 0 a U O L, U ai 1� W d Cd a 1.4 U 'b Cd >ti a1 U Ca C\2 ►-- - - - - - - - - _- - -' CURB - - - - -- - - -- L-- SIDEWALK R/W LINE G .r.: +� 10' MIN. TRENCH LOCATION •r" CLEARANCE FROM DRIVEWAY F LIGHT BASE AND JUNCTION BOX LOCATIONS O SCALE: NONE SCALE: NONE E- FUSE KITS QUICK DISCONNECT 10 AMP IN LINE FUSE KITS - S.E.C. OR EQUAL - TYPICAL DESIGN "B" JUNCTION BOX GROUND LUG - SPLICE KITS CLEAR EPDXY SPLICE KITS ON ALL THRU WIRE RUNS 2" MIN. GROUT UNDER POLE BASE 4" CONCRETE PAD Yjf �1 � #8 BARE COPPER GROUND WIRE TOP OF CONCRETE �a•S o n ° FOUNDATION TO BE LEVEL WITH TOP OF SIDEWALK OR CURB. , =1 ?i �(?i RECOMMENDED i FOR APPROVAL BY P PANEL SCHEDULE LOCATION: MONROE AVE. N H SERVICE: O 240 VAC, 10, 3 WIRE CKT NO,LOAD KVA MAIN BRKR 100 20 IS 20 KVA LOAD CKT NO 1 3731 F, 3733 F 0.6 SPACE ONLY 2 NW W SPACE ONLY LUMINAIRE SCHEDULE SPACE ONLY SPACE ONLY s SPACE ONLY SPACE ONLY 4.woF xi LUMINAIRE APPROX. MOUNTING ARM LAMP CIRCUIT2 REMARKS SPACE ONLY 10 SPACE ONLY NUMBER LOCATION HEIGHT LENGTH WATTAGE NUMBER SPACE ONLY 12 _LL TO LUMINAIRE 3731 F 51 +50.71 30 ft 8' -0' 250 Watt 1 New3 E 15 CONTACTOR &PHOTOCELL 0.5 Ci 3733 F 50 +10.71 30 ft 8'-0' 250 Watt 1 New •1 IF- •iFF--- •••iil 10213 frsre4:� I)Location is given from intersection of N.E. 12th St. & Monroe Ave. N.E. � -I W L I 2)See Panel Schedule. ELI Z Io EXPIRES��.,r 3)New Lumi no! re shall be ANSI /IES type M-C -III per City of Renton Specs. 1/4" MINIMUM 4 - ;6 - E- to DRAIN HOLE 14 5- BU /LT �y - I N6 Llnw% r'9 roue �, hn p TOP OF CONCRETE �a•S o n ° FOUNDATION TO BE LEVEL WITH TOP OF SIDEWALK OR CURB. , =1 ?i �(?i RECOMMENDED i FOR APPROVAL BY P PANEL SCHEDULE LOCATION: MONROE AVE. N H SERVICE: O 240 VAC, 10, 3 WIRE CKT NO,LOAD KVA MAIN BRKR 100 20 IS 20 KVA LOAD CKT NO 1 3731 F, 3733 F 0.6 SPACE ONLY 2 SPACE ONLY 5 SPACE ONLY SPACE ONLY s SPACE ONLY SPACE ONLY 9 SPACE ONLY SPACE ONLY 10 SPACE ONLY SPACE ONLY 12 _LL SPACE ONLY SPACE ONLY 14 15 CONTACTOR &PHOTOCELL 0.5 0.5 UTILITY RECEPTACLE Is �I a o O 0) E-I p r� Q) 0M GROUND jj r , Q) W W CLAMP I - — - W -�-2 0 a 4' CHECKED FOR COMPLIANCE %o�� Iii U� Gz (�I Pq ii TO CITY STANDARDS 2- (SIZED AS REQ'D) PVC CONDUIT O%71�i��.GGJ -®'� Date �'2 °- ,9/ wlry� LIGHTING SYSTEM SYSTEM Date f•' WAS <F CIIY OF REN10N 4 WIRES TO CONTACTOR �x ' DEPAi MAEra F PUBLIC WORKS CONCRETE Dete ' ,°� CI FOUNDATION • W KENSIN/"�ON APARrM�N -Fs 5/8 "z8` I ►I FJS vr Tr1_L '-i COPPER -CLAD 3' SQ. OR DIA. ' gf�rsrER S t LI�I-I"(INC -� GROUND ROD IONa! �-1 DESIGNED: KLV DATE: S/ 5/91 M E NAME J `5 TYPICAL LIGHTING UNDERGROUND SYSTEM DRAWN: IKV CHECKED: .ICV SCALE: 1" = 20' FIF1n eaac auk: SCALE: NONE N0. REVISION BY APPR DATE APPROVED: SHEEP: 1 OF: 2 148,:1 0294. I A I I 1A 1 I 1 II I 6 7 8 9 10 11 12 13 14 All I I I I j l 15 16 17 18 19