Loading...
HomeMy WebLinkAboutT-203003M -400AZ LIPUNAIRE SPECIFICATIONS S M•zsoA1 This specifications covers the requirements for a street lighting lumfneire with integral ballast, for use with a horizontal burning High Pressure Sodium. DETAILED REQUIREMENTS 1. HOUSING a. The housing shall be a precision aluminum die -cast. This housing shall enclose the slipfitter, reflector, lamp socket terminal board and ballast components. III. Provision shall be made on the top housing to permit leveling of the unit. c. The housing shall be of adequate size to allow for operation of alt of the components within their designed operating temperatures. d. Housing shall be able to withstand 1000 hour salt spray test. Per ASTH 117. e. The housing shall have an acrylic base elactrocoat finish, the color to be ASA.70 gray. 2. SLIPFITTER a. The slipfitter shall be suitable to accept a 1 -1/4' to 2' pipe and shall contain a pipe stop. b. Clamping and leveling of the lumiaire to the mounting pipe shall be accomplished by the tightening of 4 bolts which shall be accessible from within the unit. c. No re- arrangement of parts or separate parts shall be required when mounting the unit to either 1 -1/4' or 2' pipe. 3. LAMP SOCKET a. The tamp socket shall be a mogul porcelain enclosed. The rating of the socket shalt exceed the lamp starting voltage. Is. The screw shell shall contain integral lamp grips and the center contact shall be non- cautilever spring laded. C. The socket shall be adjustable to any of two vertical and four horizontal positions. d. Socket shall conform with TW -147 specification of EEI standards. 4. REFLECTOR a. The reflector shall be of aluminum bydro-fora construction finish with the Alglas process. b. The reflector shall be rigidly mounted within the parsing to assure a firm surface for proper sealing when the unit is closed. c. Gaskets between the reflector and glassware shall be made of Ethylene Propylene Diane Monomer Rubber. The optical assembly shall also contain an activated charcoal filter to be effective both mechanically and chemically in removing airborne particulate and gaseous matter and assure proper breathing of the optical assly. This filter shall be so loo emb ted so as at to interfere with the light distribution. S. REFRACTOR a. The refractor shall be of borosilicate prismatic glass. 6. DOOR GLASS HOLDER -DOOR a. The door glass holder -door shalt be secured and hinged to the upper housing at one end and latched to the upper housing at the opposite end with a spring laded stainless steel latch piece. The latch shall be of such size as to permit opening by a lineman when working with lineman's gloves when the lumiaire is mounted either in it's normal position or upside down. 7. TERMINAL BOARD a. The terminal board shall be molded of Fiberglass Reinforced Polyester-protective barriers between each terminal. b. The terminal screws shall he of the captive type and each screw shall be equipped with wire grips which will automatically be raised and lowered as the terminal screw is operated. Termiais shall be capable of accepting up to 06ANG conductors. c. All components are to be prewired to a single terminal board requiring only customer connections to clearly identified terminals. d. Terminal Board shall be a Dead Back design with no exposed electrical components. 8. HARDWARE a. All hardware shell be of an- corrosive or suitably protected metal, plated where necessary to prevent electrolytic action by contact with aluminum. 9. BALLAST a. The ballast shall be of the built -in design mounted within the luminaire in such a manner that it can be easily disconnected by simple disconnecting plugs. Is. The ballast and other auxiliary equippmmeent shall be mounted on a separable die -case component of the luminaire to facilitate replacement. ovum NOTES: 1. ALL WORK AND !MATERIALS SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE CITY OF RENTON STANDARDS AND SPECIFICATIONS. 2. PRIOR TO ANY CONSTRUCTION ACTIVITY, THE CONTRACTOR SHALL SCHEDULE AND ATTEND A PRE - CONSTRUCTION CONFERENCE WITH THE CITY OF RENTON CONSTRUCTION INSPECTION PERSONNEL. 3. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 4. ANY DEVIATION FROM THESE PLANS WILL REQUIRE PRIOR APPROVAL FROM THE OWNER, ARCHITECT, ENGINEER AND APPROPRIATE PUBLIC AGENCIES. S. IT SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE AND ANY OTHER RELATED PERMITS PRIOR TO ANY CONSTRUCTION ACTIVITY. 6. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY EXISTING CONDITIONS AND TO AVOID ANY OTHER UTILITIES NOT SHOWN ON THE DRAWINGS WHICH MAY BE AFFECTED. THE CONTRACTOR SHALL - NOTIFY ALL PERTINENT UTILITY AGENCIES AT LAST 48 HOURS PRIOR TO COMMENCING WORK, AND SHALL COORDINATE WITH THE UTILITIES THROUGHOUT THE PROJECT. THE ARCHITECT, OWNER AND ENGINEER SHALL BE CONTACTED IMMEDIATELY IF CONFLICTS EXISTS. 7. CONTRACTOR SHALL VERIFY EXACT LOCATION OF STREET LIGHTING WITH ENGINEER IN FIELD. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING UTILITIES. THE CONTRACTOR SHALL NOTIFY =THE AFFECTED UTILITY COMPANY AND THE CITY IMMEDIATELY UPON DAMAGE. I 1 I I Al e. The High Pressure Sodium ballast shall be of the Magnetic Regulator design rated for volts. d. Ballast core lw a inn be of high quality electrical grade - - �I��IIiIIIIIli11�L��ll:�l� �III�Ei�tIj1939 {III ate« p."gg��w®wm\t\m -N«M2 Q . steel welded together to minimize no se and assure trouble free NEDLILE operatic over the life of the luminaire. e. Balast cul ls sball be precision wound on formed insulating bobbins mad tendals Shall be of a push on type ConnlCtiOn. . r1F ARM IJATrAkAF- ?F.G f. Casponents to provide the high starting voltage required by the High 25' $1 150 Y Pressure Sodium is" shall be mounted on a plug in assembly for easy JM" 1M1 servicing. 25' B' I50 Y g. GaneraI - Compliance with tamp specifications mommttmtam The ballast shall be capable of starting and operating one 150 watt High Pressure Sodium lamp from a 1 (120,20811L 2)7 or 4801 volt 60 hz. power source within the limits The ballast, including starting specified by the lamp manufacturer. aid, must protect itself against normal lamp failure modes. The with the lamp in an open - -or ballast shell be capable of operation spurt ctremtt-- comilitfon for six months without significant loss of ballast life. The ffxtere manufacturer span submit a statement to the effect that the ballast to be furnished is in full compliance with lamp ballast specification available to the fixture manufacturer from the lamp awfactwers at the time of bidding. Lane Wttage - For momial line voltage and awful lamp voltage, the ballast design eater will not vary more than 5% from rated lamp watts. Regmlattc - At any lamp voltage, from a fall through life lamp wattage regulation spread at that tamp voltage shall not exceed 18% fair _ IDS line voltage variation. The ttmdatre mamafaettwer will supply ballast electrical data and Imp operating welt -wstt traces for moaial and + 10% rated 1 ine voltage to verify ballast perfa'aanca and compliance with lamp specification. for the rated life of the Tamp. Starting Requirements - The ballast must reliably start and operate the l�capmto ambient temperatures dam to -40 deg. F for the rated life &llastlprimary current daring starting most not exceed normal operating current. ' Lamp Current Crest Factor - The tamp current crest factor shall not exceed 1.7 for + 1011 line voltage variation at any lamp voltage, for emmfal thr'ovo-lift. Ballast Poway Factor - The power factor of the lamp ballast system, shall not drop below 9011 for 102 lfne. voltage variations at any lamp voltage. through life. Capacitor Iariaaa - The ballast design shall be such that the normal mauufaetertng tolerance for capacitors of + 62 will not cause more tbw a + 811 varieties in regalatfc througT rated lamp life for memtanine voltage. 10. f4HiTELECTRIC RECO%KLES Luminaires with photoelectric receptacles shall be in accordance with EEI -11M standards and ~red to the term me] board and quick disconnect Plugs and shall be adjustable without tools. 11. PHDTOIETRIC 150 "TT When used with the gh Pressure Sodium Lamp, the ltniaire she)) light distribution. The photometric performance of the lwfa re as a adaimw conform to the appropriate following table. rinaf- faw PNOTOGELL AND 150 WATT HP-5, - - �I��IIiIIIIIli11�L��ll:�l� �III�Ei�tIj1939 {III ate« p."gg��w®wm\t\m -N«M2 Q . t1111 jMMM® i n�,. ���i010 COQ(GRETE PAD AND LI(.1F4T 6A5E. r� srirrr.ircr.a E)(ISTIIJ(1 WOOD FL)WER RILE AND LUMIWAIRE, 1111i([ImlmHat i I /2" PVG CONDUIT (SCHEDULE 40) 1M1 1s. ]WWOMS�i>�� ELECTRICAL CONTRACTOR mommttmtam S. PROVIDE ALL STREET LIGHTING MATERIALS AS SHOWN ON DRAWING. 9. THE CONTRACTOR SHALL SUBMIT A REQUIRED TO THE CITY OF RENTON FOR MATERIALS APPROVAL AT THE EARLIEST POSSIBLE DATE.' 10. AS -BUILT DRAWINGS WILL BE REQUIRED ON COMPLETION OF tSROJECT. 11. ALL EQUIPMENT FURNISHED SHALL BE GUARAl(TEED AGAINST COMPONENT FAILURE FOR A PERIOD OF DIM YEAR FOLLOWING. ACCEPTANCE BY THE CITY. 12. TESTING OF THE ENTIRE SYSTEM SHALL BE PERFO RMED. ANY DEFECTS NOTED SHALL BE CORRECTED BEFORE FINAL ACCEPTANCE. 13. THE CONTRACTOR SHALL SUPPLY A COMBINATION OF 4- DIGITS AND ONE LETTER ON EACH LIGHT POLE. THE LETTER AND NUMBERS COMBINATION SHALL BE MOUNTED AT THE 15 FOOT LEVEL ON THE POLE FACING APPROACHING TRAFFIC. LEGENDS SHALL BE SEALED WITH TRANSPARENT FILM, RESISTANT TO DUST, WEATHER AND ULTRAVIOLET EXPOSURE. THE DECAL MARKERS SHALL BE .3 INCHES SQUARE WITH A GOTHIC, BOLD, WHITE, REFLECTORIZED, 2 INCH LEGEND ON A BLACK BACKGROUND. AN I.D. NUMBER WILL BE ASSIGNED TO EACH POLE AT THE END OF THE CONTRACT OR PROJECT BY THE CITY TRAFFIC ENGINEERING OFFICE. RECOMMENDED RECOMMENDEC FOR APPROVAL FO,nRAPPROVAL �-i o-92. BY r By P �4C'k &-• TRr hS PoaiTT - RP'N5P0►irgT!CN I i 1 I I I I Z C� IECK D i 0R Mir,PLWNCE TO L,` 4 c S7'A.4'u ARDS ?hi,/�i/,�,.fim= 1,.®.�afi2 /•/6.92 ExISTWCG no, 3E iiTE BOUNDARY LIIJE -A-/T\ - - - \ 4 ft �I \ EX `\1 � NC 'o \ . BARE G 12�45AA3. :;3 1lw(,.,5'8 d 1e8 W. BARE S ------- -C - - - - -- - 3_ I I fec'.13'8 W. MOUSE NO-4 ExiSTiQUOVERHEAID TO RREr1AIN LINE KIFILAND AVE N.E. STREET LIGHTING PLAN SCALE: t' = 20' -0' PLAN NOTES! Q LATE IJEW UGNT FIXTURE AND JUMP TION OOX A MINIMUM OF 10 FEET AWAY FROM NEW DRIVEWAY, 0 PUGET ROWER WILL RELocATE EXISTInICa UiIUTY POLE Q LUMINAIRE. E.G. SHALL RF.WWWEGT FDWER TO FIXTURE. NEW O PROVID ATO' RISER MI11 Prpwp -OFFS, coi quit ro LdmINAiRE. ON POL(E�� I AoK AT BASE OF POLE FOR UtJDERUROUND CONDUIT. ® R�EIMOVNED jYHT FI r oWER WCbD UTILITY POLE To BE 5O STIN(A OVERHEAD LINE TO BE REMOVED ey PUCEs �ETI © NWCoIDEWPLKORT R MINIIMUMSOF 3 DLJEOPER RECORD DRAWINGm�•�•��jy'" Puc. 1Om tva. � uce� AS 13 3 -�UILi 4 4 9 sm 030 GfERN6>'i O�� G U4ANGE CRDER I, PPRT 8 ` ARCHITECTS PLANNERS ENGINEERS N ORS I /6 PG_4N IQEb /E!y Renton, W.ahlnA 98055 -2977 Ph.nc(206)226 -3522 F.x :(206)228 -9115 NO. REVISION i I i I I I T i 4EN 0 I - EAIsTING HOUSE NO. i • * ARM.DPRROVIDE �GF-- L�ITJ P WR/000IRAWIIT PNOTOGELL AND 150 WATT HP-5, ® Jl1NGTl0 eOx ITH CONCRETE UD. Q COQ(GRETE PAD AND LI(.1F4T 6A5E. E)(ISTIIJ(1 WOOD FL)WER RILE AND LUMIWAIRE, - -- i I /2" PVG CONDUIT (SCHEDULE 40) - -- EX15TINU OVERHEAD ROWER LINE, E•G• ELECTRICAL CONTRACTOR R1.wy NX ae> 1�g� hl ids e� gs 9ea� s_ a vo 9°a 3 C a 0 CITY OF RENTON . .DEPARTMENT OF PUBLIC WORKS RENTON SENIOR HOUSING STREET LIGHTING PLAN GNED ..G Fit NO NN :KED SCALE 9 "= 20 -0" I- cook -.Aat- tOVEO SHEET-OF- I