HomeMy WebLinkAboutT-2053011 -1/2" CONDUIT FROM CABINET TO J -BOX - W/ 2 -Ic p8, 1 -Ic #;10 BARE CONDUCTOR LIGHTING CONTACTOR AND CONTROL CABINET PER CITY OF RENTON STANDARD DETAILS INSTALL TYPE I -A JUNCTION BOX PER CITY OF RENTON STANDARD DETAILS COORDINATE ELECTRICAL CONNECTION W/ PUGET POWER USE 3 #6 AWG U.S.E. VERIFY SVC CONNECTION W/ PUGET POWER 7D r3lGET Pd...ta - -. Scu 2CE O- ,= pwEe?_ 4 2 +0 — I i I� l� Im w to I 3�895C _ — — — — - LciM•vEi >.. E 2.0.1✓ 6' S/W ALON PROP LINE-. - nli J m rf»7 149 %To O/W 30' ROW — — — _ -- -- — — NEW 1/2 T_71-T T — — — — 3 +00 4=00 30' ROW ( , I STA 2 +25 22' LT STREET LIGHT FIXTURE "L -1" W 3'WX7'L CONCRETE PAD W/ JUNCTION BOX PER CITY TYPICAL DETAIL 240 VAC - 150WATT M -C -III PATTERN LUMINAIRE PER CITY STANDARDS USE 35' HIGH DAVIT POLE W/ 8' ARM LENGTH FOR HIGH PRESSURE SODIUM VAPOR G.E. FIXTURE STREET LIGHTING GENERAL NOTES 1. THE CONTRACTOR SHALL SUBMIT A REQUEST FOR MATERIALS APPROVAL TO THE CITY OF RENTON PRIOR TO CONSTRUCTION. 2. AS -BUILT DRAWINGS WILL BE REQUIRED ON COMPLETION OF ALL PROJECTS. 3. THE CONTRACTOR SHALL NOTIFY ALL UTILITIES REGARDING THE FACILITIES LOCATED WITHIN THE PROJECT LIMITS 48 HOURS PRIOR TO GRADING AROUND OR UNERGORUD CROSSING OF UTILITIES. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO THE EXISTING UTILITIES. THE CONTRACTOR SHALL NOTIFY THE CITY IMMEDIATELY UPON DAMAGE. 5. THE CONTRACTOR SHALL BE RESPONSIBLE TO INSTALL POLE I.D. NUMBERS AS DIRECTED BY THE TRAFFIC ENGINEER. . 6. THE CONTRACTOR SHALL VERIFY THE LOCATION OF THE PUGET POWER SERVICE POINT. 7. THE LIGHT STANDARDS, JUNCTION BOXES, AND OTHER FIXTURES SHALL BE INSTALLED IN ACCORDANCE WITH THE DETAILS HEREIN. 8. A PHOTOCELL SHALL BE INSTALLED ON LIGHT FIXTURE L -1. 9. NO HANDHOLES, POLES, OR JUNCTION BOXES SHALL BE LOCATED WITHIN THE SIDEWALK. 10. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON AND THE 1991 STANDARD SPECIFICATIONS FOR ROAD, BRIDGE, AND MUNICIPAL CONSTRUCTION 3Y WSDOT AND APWA, WASHINGTON STATE CHAPTER. IT IS THE RESPONSIBILITY OF T. :E CONTRACTOR TO OBTAIN COPIES OF THESE DOCUMENTS. IN THE CASE OF CONFLICTS, THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON SHALL BE USED. TRU -4/ -2053 BENCHMARK: CITY OF RENTON SOUTHWEST CORNER OF CONC. VAULT, CHISELED CROSS - ELEVATION = 19.39 11. CONDUCTOR TYPE FOR LIGHTING CIRCUIT: USE -XLP; CONDUCTOR TYPE FOR PHOTO CELL CIRCUIT: THHN 12. PROVIDE MINIMUM 8 TO 10 FEET CLEARANCE FROM LIGHT STANDARD TO OVERHEAD POWER LINES. COORDINATE RELOCATION OF OVERHEAD POWER WITH PUGET SOUND POWER AS REQUIRED. 13. ALL STREET LIGHTING CONDUIT SHALL HAVE A MINIMUM OF 24 INCHES COVER. The ykels Engineering Group Inc. Consulting Engineers —Civil, Municipal, Subdivisions rN1. P.O. Box 133 Kent, W'A 98035 -0133 (206) 631 -6598 alas RECOMMENDED APPROVAL wa 7 FOR � BY T- T i9 FS GIS�cFE s %ONAL E EXPlBES �iyi93 I CITY OF RENTON