HomeMy WebLinkAboutT-2091013 04 N m 0 0 0 1 rn N �a EQUIPMENT SCHEDULE MANHOLE SCHEDULE FLAG NOTES ( SHEETS E -1. E -2 "E -3 AND E-4-1 SYMBOLS TOP OF MANHOLE DBS _ DIRECTION OF DUCT BANK SLOPE. ITEM NO. DESCRIPTION CIRCUIT NOTES NAME T� ELEVATION EXCLUDING COLLARS PLUMB. 2 EA. 4 INCH RACEWAY TO NEW MANHOLE. INTERCEPT EXISTING DUCT SYSTEM. HV HIGH VOLTAGE FEEDER- 15,000 VOLTS. REMOVE EXISTING PULLBOX S -3. 2 � E LOW VOLTAGE FEEDER -600 VOLTS SL STREET AND SIGN LIGHTING VOLTS 1O LUMINAIRE TYPE Al 1 EXISTING SIGN FEEDER WITH SIGN COMMUNICATION LINE. LOCATE AND PROTECT. _ _ A DUCT BANK. SEE SCHEDULE -600 C COMMUNICATION AND TELEPHONE SERVICE O2 LUMINAIRE TYPE C WITH POLE 1 PULLBOX S -5 A TOP AT ROAD BED GRADE. RACEWAY CONCEALED. SEE SCHEDULE EXISTING SIGN SERVICE TRANSFORMER TO REMAIN. Q3 LUMINAIRE TYPE A2 2 MANHOLE S -3 D TOP AT 1 FOOT BELOW FINISHED GRADE. _4.__ RACEWAY UNDERGROUND. SEE SCHEDULE O LUMINAIRE TYPE MANHOLE S -6 D TOP AT 1 FOOT BELOW ROAD BED GRADE. R::�:_ REMOVE EXISTING H.V. FEEDERS AND PROVIDE NEW H.V. FEEDERS. SEE E4. — - — EXISTING ELECTRICAL UTILITIES B WITH POLE 1 MANHOLE S -7 A TOP AT 1 FOOT BELOW ROAD BED GRADE. � MAINTAIN IN SERVICE UNTIL NEW H.V. FEEDER IS IN SERVICE. REMOVE FEEDER AND O LIGHTING CONTROL PANEL SEE DETAIL 2 MANHOLE S -8 A TOP AT 1 FOOT BELOW FINISH GRADE. RACEWAY AS PART OF TUNNEL CONNECTION. - x - EXISTING ELECTRICAL UTILITIES TO BE REMOVED PROVIDE CONCRETE PAD DRAWING E6 © EXISTING TELEPHONE SERVICE TO HOSPITAL - - - EXISTING NON- ELECTRICAL UTILITIES. SEE OTHER SHEETS 1 O6 19" X 14" X 12" DEEP CONCRETE SEE DETAIL 1 MANHOLE CS -1 C TOP AT 65 TUNNEL UNDER EXISTING UTILITIES FOR DUCT BANK. HAND EXCAVATE TO LOCATE - - - - - - FOR WORK REQUIREMENTS. PULL BOX W/ METAL LID DRAWING E6 UNDERGROUND UTILITIES. 7 Q LUMINAIRE TYPE D WITH POLE 1 MANHOLE CS -2 C TOP AT 1 FOOT BELOW ROAD GRADE. ® RELOCATE AND LOWER EXISTING 30' POLE, LIGHT FIXTURE. REMOVE PULLBOX. NEW NON- ELECTRICAL UTILITIES AS NOTED. SEE OTHER SHEETS FOR WORK REQUIREMENTS EXCEPT WHERE NOTED MANHOLE CS -3 C TOP AT 1 FOOT BELOW FINISHED GRADE. PROVIDE NEW POLEBASE. "PROVIDE... ", "RELOCATE... ", ETC. MANHOLE CS-4 C SAME AS S8. R�::_ TUNNEL UNDER EXISTING UTILITY TRENCH. HAND EXCAVATE ONLY. TUNNEL UNDER EXISTING WALK. WALL PACK LIGHTING FIXTURE. SEE SCHEDULE FOR TYPE. PULLBOX CS -5 A TOP AT ROAD BEND GRADE. a LEE SPECIFICATIONS. MANHOLE CS -6 C TOP AT 1 FOOT BELOW FINISHED GRADE. 11 REPAIR OR REPLACE EXISTING WALK AND HANDRAIL TO PRE - CONSTRUCTION CONDITION. o POLE MOUNTED AREA LIGHTING FIXTURE r{ EXISTING AREA LIGHTING FIXTURE - MAINTAIN IN SERVICE. TELEPHONE CABLE, LOCATE AND PROTECT. EXISTING TELEPHONE PULLBOX. EXISTING AREA LIGHTING FIXTURE TO BE REMOVED OR RELOCATED. 5 EQUIPMENT IDENTIFICATION EXISTING H.V. FEEDER TO SUBSTATION. MANHOLE COLLARS WHERE DUCT BANK IS LOCATED NEAR RETAINING WALLS, VERIFY EXACT EXTENT OF LIGHTING CONTROL PANEL DIAGRAM PROVIDE COLLARS FOR THE HEIGHTS REQUIRED TO SET COVERS AT FINISH ELEVATIC N. TIE BACK ,SYSTEM BEFORE PLACING DUCT BANK. SEE GRADING PLANS AND ELEVATIONS, FOR FINISHED ELEVATIONS. PROTECT EXISTING GROUND MOUNTED FIXTURES. MAINTAIN SIGN IN OPERATION. CIRCUIT BREAKER EXISTING LIGHTED SIGN: RELOCATE TO NEW LOCATION SHOWN. RECONNECT ELECTRIC PC PHOTO CELL SUPPLY. REMOVE RACEWAY AND PULLBOX AT EXISTING LOCATION. ct CONTACTOR COIL EXISTING IRRIGATION LINE, IRRIGATION CONTROL STATIONS AND CONTROL WIRING. NORMALLY OPEN (N.O.) CONTACTS RELOCATE LINE UPWARD AS NECESSARY AT DUCT BANK CROSSING. UTILIZE NEW MATERIALS TO MATCH EXISTING MATERIALS. -;4F NORMALLY CLOSED (N.C.) CONTACTS PROVIDE JUNCTION BOX SURFACE MOUNTED ON INSIDE OF TUNNEL WALL. CORE DRIVE WALL FOR RACEWAY. LOCATE CORE DRILL HOLE BETWEEN REINFORCED STEEL N.V. ONE -LINE DIAGRAM EXISTING CABLE CONDUIT AND WIRE SCHEDULE DUCT BANK SCHEDULE NEW CABLE RUN NO. DESCRIPTION NOTES RUN NO. DUCTS NOTES -_X X x t'sr1NG CABLE TO BE REMOVED O2 4 O 5" PRIMARY SYSTEM j— SPLICE 1� (1 ") 2 #10 + 1 #10 G. O3 8 ® 5" PRIMARY SYSTEM �-CE- ") JUNCTION 2� (1 2 #10 + 1 #10 G. O 2 ® 4" PRIMARY SYSTEM E- A (1 ") 4 X10 + 1 #10 G. O5 6 ® 5" PRIMARY SYSTEM ��— FUSED H.V. SWITCH &4 (1 ") 2 #10 + 1 #10 G. SURFACE MOUNTED O 4 ®4" AND 4 ®5" COMMUNICATION SYSTEM ... POWER TRANSFORMER S (1 -1/4 ") 4 #10 + 1 #10 G. SURFACE MOUNTED �— MO C.T.'S AND POWER METER A (1 ") 4 #10 + 1 $10 G. CONCEALED IN ROADWAY E?� (1 -1/4 ") 4 #10 + 1 #10 G. ABBREVIATIONS R (1 -1/4 ") 4#10 + 1 #10 G. A (1 ") 2 #10 + 1 X10 G. EXTEND EXISTING RACEWAY k CB CIRCUIT BREAKER (OR CATCH BASIN) PULL NEW CONDUCTORS. EXIST. EXISTING ® (1 ") 2 #10 + 1 $10 G. GENERAL NOTES 1. DUCT BANK ELEVATIONS ARE CONTROLLED BY DRAINAGE REQUIREMENTS. FC FOOTCANDLE O1 SEE LIGHTING CONTROL PANEL DUCT BANK WILL TYPICALLY BE DEEPER THAN REQUIRED BY CODE. DIAGRAM ON E -6. G. GROUND [WIRE] 2. ALL DUCT BANKS SHALL BE SLOPPED TO DRAIN TO A MANHOLE OR PULLBOX r WITH A MINIMUM SLOPE OF ONE (1) PERCENT. � 11 io t NTS NOT TO SCALE P POLE PB PULLBOX RGS RIGID GALVANIZED STEEL RECOMMENDED SPEC. SPECIFICATION [SECTION] FOR APPROVAL / BY 4`SAl W/ WITH CITY OF RENTON DEPARTMENT OF PUBLIC WORK' S PAKLI N G ` -�`� SOUTH 43rd STREET G �j jj jjDO if v ENGINEERS �i,\ VALLEY MEDICAL CENTER AND ELECTRICAL SYMBOLS AND SCHEDULES usn.a open" ENGINEERING COMPANY PLANNERS ? b. V DEaIQEa DA BQIS IV� DAIS 3 �*t kL WMW FILE NO: DRAwmc Na E1 7.0� �ts �t��� ' x.mc�""iwaeroaa"ce SEATTLE WASHINGTON .- ��r�AG �A a� °` r4 a�a AR ow+aw scuE NDY 1D srAIE Na REVISION BY er DALE APPROVM sN¢EY No- 89 av 81 Cn . T-69161 SGANIJEG OCT - #160 #� 50 8 2� IX w �L