HomeMy WebLinkAboutT-209501GENERAL NOTES
CONSTRUCTION NOTES
1. All work shall be in accordance with the City of Renton Standards Specifications and
O
Install new flat lens cobra head 100W HPS, 240V, Medium Cutoff Type III
these plans.
NO.
Distribution on 30' Davit Pole with 6' arm. Also install WSDOT Type I
1
3863B
Junction Box (See Standard Plan J -11a) and pad foundation.
2. The locations of features shown are approximate and shall be verified in the field by
2 - #8 AWG (USE -XLP)
Lighting
the contractor as necessary.
O
Install new flat lens cobra head 10OW HPS, 240V, Medium Cutoff Type III
3865B
1 +OOW
Distribution on 25' Davit Pole with 6' arm. Also install WSDOT Type I
3. Install ail street lighting materials shown on the plans, except where noted. All materials
Lighting
Junction Box (See Standard Plan J -11a) and pad foundation_
shall be new and of the best available grade or quality, except where noted.
— I _
2 #5 1
6
_J I
0 +42
OInstall
photocell on luminaire #4.
4. The contractor shall submit a request to the City of Renton for materials approval at
33
(Schedule 40)
the earliest possible date.
O
Service Cables (3 - #2's) and Conduit (2" Schedule 40) shall connect from
2"
2 - #8 AWG (USE -XLP)
Service Cabinet to nearest Puget Sound Power & Light power source.
5. All work shall be consistent with utility agency requirements. The contractor shall contact
(Schedule 80)
3 - #10 (USE -XLP)
all pertinent utility agencies 48 hours before commencing work and shall coordinate the
O
Install Service Cabinet at Sta. 1 +70, 18' LT.
work with the utilities throughout the project.
Lighting
55
6. The contractor shall be responsible for any damage to existing utilities_ The contractor
3 - #10 (USE -XLP)
Photocell
shall notify the affected utility company and the City immediately upon damage.
49' LT
1 - #8 Bare Ground
7. The contractor shall notify the City of Renton Field inspection Division (277 -5570) for
A -2
2"
inspection purposes, 24 hours before commencing work. No work shall be covered until
Spare
A
it has been examined by the engineer.
4 - #8 AWG (USE -XLP)
Lighting
8. All conduit shall be PVC Schedule 40 unless noted otherwise.
(Schedule 40)
3 - #10 (USE -XLP)
9. All conduit cover shall be 24 inches.
? RD -at 1 -2045
j
6
I
`';
12
]j
5 4
R J ED 2
3
7 AS
we
frt
01 1
�II
10
#7
1
#6
� 11
WIRING SCHEDULE
RUN
CONDUIT
CONDUCTOR
COMMENTS
NO.
SIZE
1
3863B
1 +00E
2"
2 - #8 AWG (USE -XLP)
Lighting
1A
(Schedule 40)
I 4
#
3865B
1 +OOW
2"
2 - #8 AWG (USE -XLP)
Lighting
A2
(Schedule 80)
— I _
2 #5 1
6
_J I
0 +42
2"
2 - #8 AWG (USE -XLP)
Lighting
33
(Schedule 40)
1 - #8 Bare Ground
Ground
1 +72
2"
2 - #8 AWG (USE -XLP)
Lighting
A4
(Schedule 80)
3 - #10 (USE -XLP)
Photocell
3 +22
2"
2 - #8 AWG (USE -XLP)
Lighting
55
(Schedule 40)
3 - #10 (USE -XLP)
Photocell
4 +45
49' LT
1 - #8 Bare Ground
Ground
A -2
2"
OPEN
Spare
A
2"
4 - #8 AWG (USE -XLP)
Lighting
A -2
(Schedule 40)
3 - #10 (USE -XLP)
Photocell
? RD -at 1 -2045
LEGEND
10 0 10 20
® TYPE I JUNCTION BOX SCALE IN FEET
Q TYPE II JUNCTION BOX
�!( LUMINAIRE AND POLE
® SERVICE CABINET
— — CONDUIT [
A WIRE NOTE
O CONSTRUCTION NOTE
- - -- R.O.W.
POLE SCHEDULE
POLE
NO.
1 DA YTOV ( A VENUE
POLE
LOCATION1
I POLE
OFFSET
MOLINTING1
HEIGHT
ARM
LENGTH
CIRCUIT
NO.
COMMENT
1
3863B
1 +00E
24' LT
30'
J'. 2
A -1
4 +00
I 4
#
3865B
1 +OOW
24' LT
3 +0o 2 00
1 +00
A -1
N.E. 16th Street
— I _
2 #5 1
6
_J I
0 +42
19' LT
25'
2 #3 I
/
Dayton Avenue
4
3867B
1 +72
19' RT
25'
6'
A -2
Dayton Avenue
with Photocell
5
3866B
3 +22
19' LT
25'
6'
A -2
Dayton Avenue
6
3869B
4 +45
49' LT
25'
6'
A -2
CUL-DE-SAC See Plans ns
7
)
4 +45
49' RT
25'
6'
A -2
1
1
5
1 1
I I
iI
I
12
I
13 ! 14
R J ED 2
II
O +0BCNEA ;Pl3TR
I I
POLE SCHEDULE
POLE
NO.
POLE
1. D. #
POLE
LOCATION1
I POLE
OFFSET
MOLINTING1
HEIGHT
ARM
LENGTH
CIRCUIT
NO.
COMMENT
1
3863B
1 +00E
24' LT
30'
6'
A -1
N.E. 16th Street
2
3865B
1 +OOW
24' LT
30'
6'
A -1
N.E. 16th Street
3
3864B
0 +42
19' LT
25'
6'
A -1
Dayton Avenue
4
3867B
1 +72
19' RT
25'
6'
A -2
Dayton Avenue
with Photocell
5
3866B
3 +22
19' LT
25'
6'
A -2
Dayton Avenue
6
3869B
4 +45
49' LT
25'
6'
A -2
CUL-DE-SAC See Plans ns
7
3868B
4 +45
49' RT
25'
6'
A -2
CUL -D See P laaSAC
ns
CONTACTOR CABINET
SERVICE &
CIRCUIT No.
MAIN
BREAKER
BRANCH
BREAKER
CONTACTOR
COMMENTS
Service
100 amps
—
—
—
A- 1/240V
—
15 amps
30 amps
A- 2/240V
—
15 amps
30 amps
WM E POPP ASSOCIATES
TRANSPORTATION • CWL - CNOINlEN�
BELL -E WASHINGTON
0+Y 0 DAYTON. AVE
E' Est
II I
rRC AL 3
Rye —Y
1 +00w
1 I #2
CHECKED FCR COMFUAiNCE
TO CITY SIAWKRDS I
77LLr�rLr iip7la4xtCCe 5 -� -%3 C
I I f C I II
1n 1n '1 7 9r 11r- 4 1 4 n 4 n 11 1n n n n n n nl�r -1nr-N t-1%v