Loading...
HomeMy WebLinkAboutT-210701INSTALL II 40 V T1� 0 STREET LIGHTING NOTES o AT APROX STA_ 0+31. 6w ALT - CD - - - - - - - i ]. ALL WORK SHALL BE TI ACCORDANCE KITH THE CITY OF RETEST BENCHMAW. TOP OF M IT N CASE AT iQti� St _ �O STANDARD SPECIFICATIONS AND THESE PLANS AND THE LATEST ME 10th: ST, R ANACORT£S AVE, -� _ - _ - _ ELEV. a 40&2M CITY OF RENTOW DATW r - 7-- EDITION IC THE STANDARD SPECIFICATIONS FOR ROAD, BRIDGE I APR SER LOCATK)N AND WASHINGTON CONSTRUCTION BY WSDOT AND APWA WASHINGTON STATE CHAPTER. IT IS THE RESPONSIBILITY OF _ I TO BE AVSTALLED BY UWWFY COWANY THE CONTRACTOR TO OBTAIN COPIES OF THESE DOCUMENTS IN THE CASE OF CONFLICTS THE STANDARDS AND SPECIFICATIONS a OF THE CITY OF RENTON SHALL BE USED_ a� v 2 THE LOCATIONS OF FEATURES SHOWN ARE APPROXIMATE AND SHALL BE VERIFIED IN THE FIELD BY THE CONTRACTOR AS NECESSARY. FOR UTILITY LOCATE CALL 1 -800- 424 -5555- i 3. ALL MATERIALS SHALL BE NEW AND OF THE BEST AVAILABLE GRADE OR QUALITY, EXCEPT AS NOTED. ALLL EQUIPMENT 40 ® �® BD = °o I v 1 I FURNISHED SHALL BE GUARANTEED AGAINST COMPONENT j - 2 FAILURE FOR A PERIOD OF ONE YEAR FOLLOWING ACCEPTANCE BY THE CITY. SCQ 72 Feet W e d- I ii A THE CONTRACTOR SHALL SUBMIT A REQUEST TO THE CITY OF I I I RENTON TRAFFIC ENGINEER FOR MATERIAL APPROVAL AT THE 73 EARLIEST POSSIBLE DATE J 5. ALL WORK SHALL BE CONSISTENT NTH AFFECTED UTILITY CON AGENCES REQUIREMENTS. THE CONTRACTOR SHALL CONTACT ALL PER71NENT U77LITY AGENCIES FORTY -EIGHT (48) HOURS BEFORE COMMENCING WORK, AND SHALL COORDINATE THE i WORK NTH UTILITIES THROUGHOUT THE PROJECT. m 2 I 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO \ 0 2 7210 EXIS77NG UTILITIES. THE CONTRACTOR SHALL NOTIFY THE + ' AFFECTED U77UTY COMPANY AND THE CITY IMMEDIATELY UPON ✓' I DAMAGE ✓�� I 7. THE CONTRACTOR SHALL NOTIFY THE CITY OF RENTON CONSTRUC77ON ENGINEERING DIVISION AT 277 -5570 FOR LLJ z I I 73 INSPECTION PURPOSES TWENTY -FOUR (24) HOURS BEFORE r ltJ ` HHASMBEEN EXAMINED BY ENGINEER. BE COVERED UNTIL IT V 25 Q 8. CAUTION - OVERHEAD ELECTRICAL SERVICE LINES ARE NOT SHOWN ON THE DRAWINGS THE CONTRACTOR IS RESPONSIBLE ! • 7467 .l �1 m FOR DETERMINING THE EXTENT OF ANY HAZARD CREATED BY v m NDt/sa: (71v) OVERHEAD ELECTRICAL POWER IN ALL AREAS AND SHALL / FOLLOW PROCEDURES DURING CONSTRUCTION AS REQUIRED BY aDg 3 LAW AND REGULATIONS AND TAKE PRECAUTIONS THAT MAY BE „ O " 1 ° 7,428 REQUIRED. MINIMUM CLEARANCE FROM OVERHEAD POWER TO O q, THE STREET LIGHT STANDARDS IS 10 TO 16 FEET, DEPENDING ON 70 Z VOLTAGE 7 24 r �; Q\ 9. MAINTAIN CLEARANCES FROM SUCH FEATURES SUCH AS 7762 " \ s PROPERTY LINES, LOCA77ON OF DRIVEWAYS, FIRE HYDRANTS AND 5 ANY OTHER FEATURES. MINIMUM CLEARANCE FROM DRIVEWAYS m vM �p 3 SHALL BE 10 -FEET, MINIMUM CLEARANCE FROM CURB 30- INCHES o° S, 10. ALL CONDUCTORS FOR STREET LIGHTING TO BE TYPE USE -RHH ¢ 7P-6 ¢ (XLP) INSULATION. CONDUCTOR INSULATION FOR PHOTO CELL 18 32419 Lam, k } \ CIRCUIT 70 BE TNHN. 17 7.214 11 a„ 9.336 m, 0 11. CONTINUITY AND MEGGER TESTS SHALL BE CONDUCTED AND CHURCH 9.064 7.203 8.071 8.074 \ 126 ANY DEFECTS N07ED SHALL BE CORRECTED BEFORE FINAL ® 22 m 23 \ ACCEPTANCE OF THE ELECTRICAL SYSTEM FOR STREET LIGHTS. L'A2 7` 7.208 7928 12- THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL 5 COORDINATION NTH THE POWER COMPANY FOR SERVICE WORK AND ALSO PROVIDE AND INSTALL ALL MATERIAL NOT PROVIDED 9' 7P -3.be .r 7.567 BY THE POWER COMPANY. 8=45 2s 7 a " 13. NO HANDHOLDS POLES, OR JUNCTION BOXES SHALL BE LOCATED TA 5 +04.88 AVE o sD2 WITHIN THE SIDEWALK. _ N. E. 9th _PL = STA 10 +00 ST 14. ALL STREET UGH77NG CONDUIT SHALL HAVE A MINIMUM OF 24 16 - - OTP-2 - - - -73 +00 7 - - - - - - - - - 6 - - - - ° 4 INCHES OF COVER. B 12i OO - o 7,729 END OF ST7�Er A aa+ 6 15. PROVIDE AS BUILT DRAWINGS AT COMPLETION OF PROJECT. STA 13+98.57 .22 as 41 I 7.300 LUMINAIRE SCHEDULE CL OF ROAD LUMINAIRE �5 LUMINAIRE POLE TO LAMP MAST CIRCUIT IDENTIFICATION NUMBER LOCATION CL OF POLE WATTAGE HEIGHTw ARM NO. NO, REMARKS 1 0 +56 18.5' LT 100 25' 6' 1 3901B 4 15 13 3: 12 a 11 - 10 - 9 - I p 2 1 +96 18.5' LT 100 25' 6' 1 3903B 9.704 14 8,023 8,544 A 8 � 7 N ® 7917 8.844 4644 &644 9,234 I 7568 3 3 +59 18.5' LT 100 25' 6' 1 3905B 1 O 4 5 +02 18.5' LT 100 25' 6' 1 3907B aka 5 6 +65 18.5' LT 100 25' 6' 1 3908B 66 6 11 +01 18.5' RT 100 25' 6' 1 3909B 78 71 60 a" 60 60 60 60 65 ° 7 12 +65 18.5' LT 100 25' 6' 1 3910B ns END OF AVENUE �eO7 8 14 +43 17.6' LT 100 25' 6' 1 3911B WIRING SCHEDULE LEGEND STA 6+74.58 T- x STANDARD DAVIT POLE, SEE STREET LIGHTING DETAILS RUN NO. CONDUIT CONDUCTORS �"`t TYPE M -S -3 H.P.S. FLAT LENS LUMINAIRE, ARM AND ALUMINUM DAVIT STYLE POLE . A 2' PVC (SCHEDULE 40) 3 - #2 (SERVICE) CITY OF RENTON C= CONCRETE PAD LIGHT BASE AND TYPE 1 JUNCTION BOX DEPARTMENT OF PUBLIC WORKS A2 1.5' PVC (SCHEDULE 40)2 - #8, 3 - #12 (PHOTOCELL), 1 - #6 BARE PVC CONDUIT (SEE WIRING SCHEDULE) �� ^ _ MISSION HILLS SUBDIVISION 1.5' PVC (SCHEDULE 40)2 - #8, 3 - #12 (PHOTOCELL), 1 - #8 BARE ® i STREET LIGHT CONTACTOR CABINET AND FOUNDATION 4 1.5' PVC (SCHEDULE 40)2 - #8 i =.- -:} $ 26597 �� N0. REVISION BY APPR. DATE STREET LIGHTING PLAN DESIGNED EMS 1.5' PVC (SCHEDULE 40)2 - #8, 1- #8 BARE ® TYPE 1 JUNCTION BOX WITH CONCRETE PAD i x ! F` ONAIENZ'` (p /I �If TRAnirVn/��AmON PLA�Q DRANK DJL DA FILE NO. 80649 1 A Lam, j1 tl IYL- AM ENGMEE 113 INC. V CHECKED SCALE _ FlELO BOOK PAGE 1.5' PVC (SCHEDULE 8D)2 - #8 T/I�O _� I-�'�� ❑T POWER TRANSFORMER BY OTHERS I �•�2�9.3� 1RN* 2101 112TH AVE NE, SUITE 110 11 KK 3 5 u �; BELLEVUE WA 98004 (206)455 -5320 APPROVED pIRECTOR CIF PUB C WORKS �T OF 5 t r I I 1 t 1 A l I 7 1 Y 1 1 I I i 1 A 1 i I I I i !