Loading...
HomeMy WebLinkAboutT-216401W f f 1 V f '— — — — — — — — — — VI_ I f � ?- - -� __ — - - - -- A . / A 4 +00 5+00 TALBOT ROAD I � N N +I II F- a TQ PLIGET POWER r o n i 1 `1 I 5FRVICE_ IZZA5INET 9 7 +00 ---- — —_ — - — 8 +00 NOTE: IT IS THE CONTRACTOR'S RESPONSIBILITY TO GIVE THE CITY OF RENTON TRAFFIC ENGINEERING DEPARTMENT 24 HOURS NOTIFICATION OF WORK TO BE PERFORMED ON PROJECT FOR INSPECTION PURPOSES. 235 -2620. CITY OF RENTON STANDARD SPEC. 8- 20.3(2) "NO WORK SHALL BE COVERED UNTIL IT HAS BEEN EXAMINED BY THE ENGINEER." NO WORK SHALL BE STARTED UNTIL MATERIALS HAVE BEEN SUBMITTED AND APPROVED BY THE CITY OF RENTON. CONSTRUCTION NOTES AO P.S.P. & L. TRANSFORMER. CONTRACTOR PROVIDED SERVICE CABINET, CONDUIT, AND CONDUCTORS TO TRANSFORMER. 2" SCH. 40 PVC, 3 - # 2 USE -XLP. OB INSTALL LIGHTING STANDARD AND LUMINAIRE. TYPE A. OC INSTALL TYPE U J -BOX. , OD INSTALL STREET LIGHTING SERVICE CABINET, 120/240 VOLT TYPE III SINGLE PHASE GROUNDED NEUTRAL SERVICE. FOOTCANDLE LEVEL (BASED ON G.E. ISOFOOTCANDLE CURVES). S /ONAL�' EXPIRES �F THESE PLANS ARE AS•BUILT AND THE INFORMATION SHOWN ACCURATELY REFLECTS EXISTING FIELD CONDITIONS AS OF THIS DATE //// =3=°� ��Q..� ap wnsy`r cgG�r 7 o•� R32 i�yo saes o alga //- 3- 95 LEGEND -f}t —UNDERGROUND CIRCUIT: CONDUIT: 1 1/2" SCH. 40 PVC. i CONDUCTORS: # 8 USE -XLP HASH MARKS = NO. OF CONDUCTORS 9 = GROUND WIRE #10 -�-� — STREET CROSSING: CONDUIT: 1 1/2" SrP. 80 PVC. 9 CONDUCTORS: # 8 U$E -XLP HASH MARKS = NO. OF CONDUCTORS 9 =GROUND WIRE #10 ® CONCRETE PULL BOX WITH STEEL COVER, TYPE B CITY OF RENTON STANDARD, WSDOT TYPE J -20.1 STREET LIGHTING SERVICE CABINET, 120/240 VOLT, TAPE III, SINGLE PHASE, GROUNDED NEUTRAL SERVICE. Q P.S.P. & L. TRANSFORMER, 120/240 V., SINGLE PHASE SERVICE. LIGHTING STANDARD AND LUMINAIRE: (TYPE A) STANDARD: 30' TAPERED ALUMINUN, DAVIT TYPE PER CITY OF RENTON STANDARD. 12' MAST ARM. i1 FIXTURE: 150 W. H.P.S., 240 VOLT, MEDIUM CUTOFF TYPE III DISTRIBUTION (FIELD ADJUSTABLE) POWER DOOR TYPE CONSTRUCTION, DROP LENS TYPE. GE M25OA2 SERIES. GE LAMP #LU 150. NUMBER: NUMBER ADJACENT TO FIXTURE IS CIRCUIT NO. CONDUCTOR: CABLE INSIDE THE LIGHT STANDARD AND MAST ARM SHALL BE TWO CONDUCTOR STRANDED COPPER NO 10 AWG REFERRED TO AS THERMOPLASTIC POLE AND BRACKET CABLE. ASTERIX: PROVIDE PHOTOELECTRIC CELL AT STANDARD WITH AN ASTERIX. NOTE: SEE DETAIL SHEET FOR EXACT FOUNDATION, J -BOX, AND STANDARD LAYOUT AND FOR CONDUIT ROUTING UNDER SIDEWALK. CHECKED FOR COMPLIANCE TO CITY'S STANDARDS WATER UTILITY DATE FIRE DUPARTMENT fUflgj9y DATE - &,�� , !/t /Z 9___ I I PLAN REVIEW /a'" DATE MAINTENANCE UA I L I NO. I REVISION T -2/64 TOTEM ELECTRIC OF TACOMA, INC. P.O. BOX 1043 3835071 2332 JEFFERSON AVE - TACOMA WASHPIGION 98401 BY APPR. DATE APPROVED { SHEET -9 I— OF a_ o�n�cron a ruwc won,n C Kf � m O o y of w w . V \ �y LUMINAIRE SCHEDULE, TALBOT ROAD C, Se LUMINAIRE POLE LOC. C.L.TO ROAD ARM LENGTH CKT. NO. VOLTAGE DROP I I . 2501C 4+30 25L 12' 1 0.89 V. 12 13 14 26030:. 5 +80 25L 12' 1 0.47 V. 250$0 7+27 25L 12' 1 0.04 V. . _ SERVICE .. CABINET 7 +27 34L �s I � N N +I II F- a TQ PLIGET POWER r o n i 1 `1 I 5FRVICE_ IZZA5INET 9 7 +00 ---- — —_ — - — 8 +00 NOTE: IT IS THE CONTRACTOR'S RESPONSIBILITY TO GIVE THE CITY OF RENTON TRAFFIC ENGINEERING DEPARTMENT 24 HOURS NOTIFICATION OF WORK TO BE PERFORMED ON PROJECT FOR INSPECTION PURPOSES. 235 -2620. CITY OF RENTON STANDARD SPEC. 8- 20.3(2) "NO WORK SHALL BE COVERED UNTIL IT HAS BEEN EXAMINED BY THE ENGINEER." NO WORK SHALL BE STARTED UNTIL MATERIALS HAVE BEEN SUBMITTED AND APPROVED BY THE CITY OF RENTON. CONSTRUCTION NOTES AO P.S.P. & L. TRANSFORMER. CONTRACTOR PROVIDED SERVICE CABINET, CONDUIT, AND CONDUCTORS TO TRANSFORMER. 2" SCH. 40 PVC, 3 - # 2 USE -XLP. OB INSTALL LIGHTING STANDARD AND LUMINAIRE. TYPE A. OC INSTALL TYPE U J -BOX. , OD INSTALL STREET LIGHTING SERVICE CABINET, 120/240 VOLT TYPE III SINGLE PHASE GROUNDED NEUTRAL SERVICE. FOOTCANDLE LEVEL (BASED ON G.E. ISOFOOTCANDLE CURVES). S /ONAL�' EXPIRES �F THESE PLANS ARE AS•BUILT AND THE INFORMATION SHOWN ACCURATELY REFLECTS EXISTING FIELD CONDITIONS AS OF THIS DATE //// =3=°� ��Q..� ap wnsy`r cgG�r 7 o•� R32 i�yo saes o alga //- 3- 95 LEGEND -f}t —UNDERGROUND CIRCUIT: CONDUIT: 1 1/2" SCH. 40 PVC. i CONDUCTORS: # 8 USE -XLP HASH MARKS = NO. OF CONDUCTORS 9 = GROUND WIRE #10 -�-� — STREET CROSSING: CONDUIT: 1 1/2" SrP. 80 PVC. 9 CONDUCTORS: # 8 U$E -XLP HASH MARKS = NO. OF CONDUCTORS 9 =GROUND WIRE #10 ® CONCRETE PULL BOX WITH STEEL COVER, TYPE B CITY OF RENTON STANDARD, WSDOT TYPE J -20.1 STREET LIGHTING SERVICE CABINET, 120/240 VOLT, TAPE III, SINGLE PHASE, GROUNDED NEUTRAL SERVICE. Q P.S.P. & L. TRANSFORMER, 120/240 V., SINGLE PHASE SERVICE. LIGHTING STANDARD AND LUMINAIRE: (TYPE A) STANDARD: 30' TAPERED ALUMINUN, DAVIT TYPE PER CITY OF RENTON STANDARD. 12' MAST ARM. i1 FIXTURE: 150 W. H.P.S., 240 VOLT, MEDIUM CUTOFF TYPE III DISTRIBUTION (FIELD ADJUSTABLE) POWER DOOR TYPE CONSTRUCTION, DROP LENS TYPE. GE M25OA2 SERIES. GE LAMP #LU 150. NUMBER: NUMBER ADJACENT TO FIXTURE IS CIRCUIT NO. CONDUCTOR: CABLE INSIDE THE LIGHT STANDARD AND MAST ARM SHALL BE TWO CONDUCTOR STRANDED COPPER NO 10 AWG REFERRED TO AS THERMOPLASTIC POLE AND BRACKET CABLE. ASTERIX: PROVIDE PHOTOELECTRIC CELL AT STANDARD WITH AN ASTERIX. NOTE: SEE DETAIL SHEET FOR EXACT FOUNDATION, J -BOX, AND STANDARD LAYOUT AND FOR CONDUIT ROUTING UNDER SIDEWALK. CHECKED FOR COMPLIANCE TO CITY'S STANDARDS WATER UTILITY DATE FIRE DUPARTMENT fUflgj9y DATE - &,�� , !/t /Z 9___ I I PLAN REVIEW /a'" DATE MAINTENANCE UA I L I NO. I REVISION T -2/64 TOTEM ELECTRIC OF TACOMA, INC. P.O. BOX 1043 3835071 2332 JEFFERSON AVE - TACOMA WASHPIGION 98401 BY APPR. DATE APPROVED { SHEET -9 I— OF a_ o�n�cron a ruwc won,n C Kf � m O o y of w w . V \ �y C, Se VA r 1 1 ! gI I I ! A I I I A I I& g I A I I I A I 1 I 1A I I I I I Al 19 18 17 16 15 14 13 12 11 10 9 8 7 6 R146- Mi RO OX 6 7 8 .9 10 11 sO 3 4 12 13 14 15 16 17 18 19 2