Loading...
HomeMy WebLinkAboutT-220806SWV4, SEC 8, T 23 N, R 5 E, W.M. I U PAVEMENT MARKINGS LEGEND (*THIS SHEET) * I DOUBLE YELLOW, TYPE I AND TYPE 2d LANE MARKERS * 2 WHITE, BROKEN LINE, TYPE I AND TYPE 2e LANE MARKERS - -- — -- -- = * 3 DOUBLE WHITE, TYPE I AND TYPE 2e LANE MARKERS * 4 DOUBLE YELLOW, 6" SOLID PAINT LINES * S WHITE, THERMOPLASTIC TURN ARROW 6 WHITE, 24" THERMOPLASTIC STOP BAR "° m -- - - - -— F * 7 WHITE, THERMOPLASTIC CROSSWALK, 10' WIDTH UNLESS OTHERWISE NOTED F — — — _ 2 O * 8 PRECAST TYPE "C" TRAFFIC CURB LI w 9 YELLOW 10" RAISED BUTTONS, 3' ON CENTER w - 2 r . , -- m In �'� '\ ,i` `" - ,� , . ,` r - BUS - -- 10 WHITE, 12" SOLID PAINT LINE .r L25 -- - -� - - -- N W -_- -- - —'— -- -- - -� - - - -- II YELLOW, 12" SOLID PAINT LINE V) - 2 PARK AVE. N o + _ - 40 B ° " + O SIGNING LEGEND rn 411 42 B 5 _ Q r7 REMOVE D STORE EXISTING BUS STOP" SIGN AND POST (METRO WILL PICK-UP AND INSTALL) N 0 °57'29" E' Q I MOV AN 0- -L/ v _ R =150, — T: `R =150' I I 3 z 3 REL.00IATE EXISTING NGSBOEI "BOEING" SIGN AND RPOST NBACK V CLEAR OF NEW SIDEWALK, { J 4 RELOCATE EXISTING "BOEING" SIGN AND POST BACK 5' CLEAR OF WALLS. — J -- _ 5 RELOCATE EXISTING "BOEING" SIGN AND POST BACK 2' CLEAR OF NEW WALLS. U - — _ ��_;,.,w,— ( — — F' 6 RELOCATE EXISTING "R2 -I (30 MPH)" SIGN ON TO ILLUMINATION POLE. F- L23 L22 _ y 7 RELOCATE EXISTING "KENNY'S" SIGN AND POST BACK V CLEAR OF NEW SIDEWALK. J — 4 4 2 I I 2 .. I 'I fi 6 10 3 4 — _ _ _ V2' _ _ ILLUMINATION CONSTRUCTION NOTES 6 2 8 ` a 2 -- -;� \ 3 �, I 3 I INSTALL GENERAL ELECTRIC M -400 A2 POWR /DOOR LUMINAIRE WITH MEDIUM TYPE III B M 1 TYPE I JUNCTION BOX ADJACENT TO LUMINAIRE PER CITY OF RENTON M M - - f X CUTOFF OPTICS, 400 WATT HIGH PRESSURE SODIUM LAMP, 35' MOUNTING HEIGHT, AND FIXED M ti p ti BASE TYPE. INSTALL T +a + +.; '+ � STANDARD PLAN J014. 2 REMOVE EXISTING JUNCTION BOX AND EXISTING WIRING. a(,). 3 REMOVE EXISTING LUMINAIRE. 4 INSTALL TYPE I JUNCTION BOX. 5 INSTALL NEW LUMINAIRE ON NEW SIGNAL POLE. 6 EXISTING LUMINAIRE TO REMAIN. 7 COORDINATE WITH PUGET POWER FOR DISCONNECT OF ELECTRICAL SERVICE OR RELOCATE BEFORE RE- WIRING. 8 EXISTING JUNCTION BOX AND ILLUMINATION WIRING TO REMAIN. 9 EXISTING YARD LIGHT TO REMAIN. 10 SPLICE NEW ILLUMINATION CIRCUIT TO EXISTING ILLUMINATION WIRING IN THE EXISTING JUNCTION BOX. If RELOCATE EXISTING YARD LIGHT (I' MIN. CLEAR OF SIDEWALK). 12 REMOVE EXISTING CONCRETE PAD. 13 RELOCATE EXISTING PAD MOUNTED TRANSFORMER (BY OTHERS). 14 RELOCATE EXISTING SERVICE CABINET TO STA. 44 +44(44'RT). CONDUIT AND WIRING SCHEDULE RUN NO. A CONDUIT CONDUCTORS 1 II %p' PVC SCH 40 2 -•8, 1-'8 GROUND 2 1 %Z" PVC SCH 40 2-'8 3 III /p" PVC SCH 80 2-E8 4 III /Z" PVC SCH 40 2- 8, 1-58 GROUND, 3 -'14 PHOTOCELL 5 I %p` PVC SCH 40 2 -'8, 3-•14 PHOTOCELL 6 II /p" PVC SCH 80 2 -•8, 3-•14 PHOTOCELL 7 I %p" PVC SCH 40 2-'6, 110 VOLT FOR IRR. CLOCK w O co a w w N O O M Q d H V) w Z J 2 U F— Q t0s EDA 20 10 0 20 40 PROJECT N SCALE: I " =20' 07- 01 -033i STA 29 +04 STA 74 +5 I f$ I f I I I ]CI I I I 'A I I 1 1 20 19 18 17 18 15 14 13 12 11 10 9 8 7 6 MICR6BOX R14 Imo — M M 1— GENERAL ILLUMINATION NOTES w w 2 I CONSTRUCT CONCRETE PAD FOR PROPOSED STREET LIGHTING AND JUNCTION BOX PER N CITY OF RENTON STANDARD PLAN J014 AND J015. w 2 STREET LIGHTING POLES SHALL BE LOCATED 1'-6" FROM CENTER OF THE POLE TO w N BACK OF NEW SIDEWALK. O 3 ALL PROPOSED ILLUMINATION CONDUIT RUNS (TRENCH) SHALL BE LOCATED 2' FROM O BACK OF CURB. N 4 REFER TO SIGNAL PLANS FOR ILLUMINATION AND INTERCONNECT CONDUIT AT NLUM do TL Q 5 ALL LUMINAIRES TO BE REMOVED SHALL BE FIRST DE- ENERGIZED AT THE SOURCE AND THEN 4?21016 t— REMOVE ALL EXISTING LIGHTING FICTURES. COORDINATE WITH PUGET POWER FOR LUMINAIRES to ON POWER POLES. COORDINATE WITH CITY OF RENTON, TRAFFIC DIVISION FOR OTHERS. N°`4a'; zThese record drawings reflect certain J 2- W, o-c "� t 3 °° 9 t;,? pensions, details, specircations, and l revisions prepared by others or obtaired from �' record drawings which have not been indepordendy ver'itled b Entrance. As result. EntranGO is Q a not responsible for ;he accuracy, am.mviatenew Or _ y ,. comoleteness ct Such Information dead In thews record drawing nntatlo ^5. E N T R A N C O ENGINEERS • SCIENTISTS • PLANNERS • SURVEYORS • c ' 36 c ,? 16104 m 9fG I St ERE' �Sm fC I ST ERE' rye tY'rw Fs8r0 NAi ENO f@3 r0 NAL t E %PIPES In )S 1 E%PiRES 0 Lq WASHINGTON ARIZONA CALIFORNIA N0. REVISION 03 2 .0 CITY OF RENTON PLANNING /BUILDING /PUBLIC WORKS DEPARTMENT PARK AVENUE NORTH BRONSON WAY NORTH TO NORTH 10th STREET CHANNELIZATION, SIGNING, ILLUMINATION & INTERCONNECT PLAN STA. 39 +00 TO STA. 47 +00 DESIGNED: DATE: DEC. 3, 1993 FILE NAME: DRAWN. M 4.1 CHECKED: SCALE: AS SHOWN FE BW%. PAG6 APPROVED: SHEET: 32 OF: 66 I A I I 6 7 8 9 10 11 12 13 14 1 I. I 1 A 15 16 17 18