Loading...
HomeMy WebLinkAboutT-221702GENERAL NOTES 1. All work shall be in accordance with the National Electric Code and these plans. 2. Unless otherwise noted, the location of features shown are approximate and the exact location will be established by the Engineer in the field. 3. Install all street lighting materials shown on the plans, except where noted. All materials shall be new and of the best available grade or quality. 4. The contractor shall submit a request to the City of Renton for materials approval at the earliest possible date. 5. All work shall be consistent with utility agency requirements. The contractor shall contact all pertinent utility agencies 48 hours before commencing work and shall coordinate the work with the utilities throughout the project. 6. The contractor shall be responsible for any damage to existing utilities. The contractor shalt notify the affected utility company and the City immediately upon damage. 7. The contractor shall notify the City of Renton Field Inspection Division (277 -5570) for inspection purposes, 24 hours before commencing work. No work shall be covered until it has been examined by the engineer. 8. All conduit shall be PVC Schedule 40, except for street crossings, which will be PVC schedule 80. 9. All conduit cover shall be 24 inches minimum. 10. Minimum conduit is 1 1/2 ". 11. Pole numbers will be designated by City of Renton. Private poles will be preceded by the Letter "P " 12. Ali pole cable to be 10/2 stranded bracket cable. 13. Each pole to be grounded and bonded as per N.E.C. ground to return to main isolated ground bus in service center. 14. All lighting conduit to be routed under sidewalk - then to pole or pole base behind sidewalk. WHU NG SCHEDULE Circuit No. CONDUIT SIZE CONDUCTOR COMMENTS *A 1.5" Sch. 40 PVC #t 248 THHN Lighting % VOLT DROP I 1 -910 Ground 0+34 2 1.5" Sch. 40 PVC 2-48 THHN Lighting 1 .04 1-#10 Ground P0053C 3 1.5" Sch. 40 PVC 2 -#8 THHN Lighting Post top 1 1410 Ground 3 4 13" Sch. 40 PVC 2 - - #S THHN Lighting 25' 10" 1-#10 Ground .38 5 2" Sch 40 PVC 3- #2 THHN service # 1 2 17. 1 #10 GRND FROM CC TO POLE #9 2 #8 & 1 910 GRND FROM POLE 9 TO 13C EPDXY FILL EPDXY FILL INLINE SPLICE WYE SPLICE col Ir"C IZIT FUSE KIT I SPLICE KIT DETAILS DIAMETER = 7/0 I.n #w O ADOPTED �4 -7/8 "-mil DWG. NAME: JR -12" e SP PACE: J013 LOAD LINE POLE NO. 1/4" FUSE FUSE KIT SEC. 1791-SF POLE LOCATION POLE OFFSET MOUNTING HEIGHT ARM LENGTH CIRCUIT NO. % VOLT DROP I POOSIC 0+34 y POLESCHEDULE POLE NO. POLE I.D.# POLE Sta. POLE LOCATION POLE OFFSET MOUNTING HEIGHT ARM LENGTH CIRCUIT NO. % VOLT DROP I POOSIC 0+34 Tract B 22' 12' Post top 1 .04 2 P0053C T 4 Tract B 20.5' 12' Post top 1 .17 3 P0055C 0 +75 Lot 48 NW 20.5' 25' 10" 1 .38 4 P0057C 414V Lot 48 S 20.5' 25' 10" 1 .52 5 P0059C 1 +50 Lot 50 20.5' 25' t0" 1 .87 6 P0061C 2�+ Lot 52 20.5' 25' to,, 1 1.16 7 P0063C +�6774� i+BU- rot 54 20 S' 25' 10" 1 1.44 8 P0065C 4 +92 Lot 56 20.5' 25' 10" 1 1.70 9 P0067C 4+-I& Lot 58 20.5' 25' 10" 1 1.93 10 P0066C Lot 60 20.5' 12' Post top 1 2. I S 11 P0068C 6+92 Lot 60 20.5' 12.' Post top 1 2.19 12 EP00�72C C_ Lot 59 20.5'. 12' Post top 1 2.24 13A -7fi33- Tract G 24' - 12' Post top 1 2.26 13B P0074C - }+89 -7 Tract G 32'' Sti Post top 1 2.29 13C 1758C 7+90 Tract G 41' 30' 8' 1 2.30 14 P0069C 1 +79 Lot 82 21' 25' 10" 2 .88 15 P0071C 2 91 Lot 79 20.5' 25' 10" 2 1.28 16 P0076C 9+34 Lot 77 NW 20.5' 25' 10" 2 1.58 17 P0078C 1 +28 Lot 77 SE 15, 25' 10" 2 2.00 18 P0080C I. Lot 72 20.5' 25' 10" 2 2.30 19 P0082C g+23- Lot 71 20.5' 25' 10" 2 2.47 20 P0084C 3+3EF Let 69 20.5' 25' 10" 2 2.61 21 P0075C -0++F Lot 66 20.5' 25' 10" 2 2.74 22 P0073C Lot 65 20.5' 25' 10" 2 2.77 23 P0050C 0 +39 Tract A 22' 12' Post top 3 .02 24 P0052C �+N- Tract A 20.5' 12' Post top 3 .25 25 P0054C 0 Lot 12 20.5' 25' 10" 3 .60 26 P0077C s - Lot 13 20.5' 25' IO" 3 � .84 27 P0079C p�H�{r674- Lot 15 20.5' 25' 10" 3 1.05 28 P0086C Lot 18 20.5' 25' 10" 3 1.22 29 P0088C �+++S -F+6&Z Lot 21 20.5' 25' 10" 3 1.36 30 P0090C - +8� Lot 23 20.5' 25' 10" 3 1.49 31 P0092C s+ 3199- Lot 26 20.5' 25' 10" 3 1.53 32 P0106C 3+ih3 Lot 39 20.5' 25' 10" 4 .95 33 P0104C + 7 Lot 36 20.5' 25' 10" 4 1.21 34 POIOOC 2 +33 Tract D N 20.5' 25' 10" 4 1.46 35 P0102C 4 +25 Tract D NE 20.5' 25' 1o" 4 1.64 36 P0098C 1 7o Tract D NW 20.5' 25' 10" 4 1.77 37 P0096C at 91531- Lot 30 20.5' 25' 10" 4 1.90 38 P0094C 0 +75 Lot 28 12' 25' 10" 4 1.93 39 P0108C of Let 18.5' 30' 8' 3 .38 40 POI IOC -L�33 Let 7 18.5' 30' 8' 3 .35 41 POI 12C 3 +22 Lot 11 18.5' 30' 3 .22 42 Poll 14C 5 +57 Lot 46 18.5' 30' 8' 1 .04 12' - AT23 -8" NECK ACORN GLOBE )0 WATT HPS -MG STD. BASE SIZE 3LACK FINISH W12117 -CA /BK ECORATIVE STREET LIGHT STANDARD (TYPICAL 9 LOCATIONS) CONTACTOR CABINET SERVICE & CIRCUIT NO. MAIN BREAKER BRANCH BREAKER CONTACTOR COMMENTS SERVICE 100 amps MB0 -7 23'071000 MEO -6 24'- 7'/1150 Circuit 41 -2P, 240V M80 -7.5 20 amps 30 amps 47' Circuit 42 -2P, 240V 27'11'/1330 MEO-7.5 20 amps 30 amps M80 -9 Circuit #3 -2P, 240V 32'10'/1570 20 amps 30 amps 32'10 "/1670 MEO -g.4 Circuit #4 -2P, 240V 5'2" 20 amps 30 amps 1 40'072100 4' SIDEWALK ta' 2TLITY NT 14' 14 SECTION A -A Ni Centrecon Series "Mrr Medium Square Pole Mounting Height - 23'0" - 40'0" Ameron Centrecon Series "M" prestressed concrete lighting poles provide the light pattern required for shopping centers, parking lots, green belts or other areas requiring decorative and roadway lighting. Application can be post top, mast arm or side mounted. These strong, durable poles are available in various aggregates and finishes. MRO Anrhnr Raca. V_ 1mM1OAAO1 n IA4�C_ Pole Leni Pale Length/ Embedded Number Weight Number Weight Depth MB0 -7 23'071000 MEO -6 24'- 7'/1150 5'0' M80 -7.5 24'7'/1120 MEO-7 277/1250 47' Me0 -2.5 27'11'/1330 MEO-7.5 29'6'/1350 4'11" eg M80 -9 29'6 "/1450 MEO -8.5. 32'10'/1570 4'11' MB0 -10 32'10 "/1670 MEO -g.4 36'0/1780 5'2" MB0 -11 36'1'/1880 MEO -10.6 1 40'072100 5'10' M80 -12.2 40'0" /2150 MEO -12.2 1 49'3'/2760 913' Appearance Code Aggregate /Finish Cement Color Gray White rawn Black N.Wnsi /Mold finish 4111 9211 NatureVPOlished 4112 #212 512 0612 Natural /Exposed 4113 9213 #513 #613 Tenazzo /Polished 4122 0222 a#4 #522 #622 Tenauo /Exposed 4123 4223 4523 #623 Sonora Gold/POlished 9232 Sonora GOld/Exposed Ordering information g MEO -7.5 � M E 0 - 8.5 1213)0 Ta S SO III P/ I v - 1 VI II P"c D =sign tixri Aran D�,icn-lcn I - Sales, mounting height dcs ma: -;hic is usually dictated by the hype of lumincirs and degree or illumination required. II - Select tenon size or side mount as required by fixture. III - Select pole which will give proper mounting height with type of arm selected. IV - Select footing requirements- anchor base or embedded style. V - Select shape of pole- round, octagonal, square. VI - Select finish from appearance codes, MAGNUFO SMO 1H RCS SERIES - RECTANGULAR CUTOFF LUMINAIRE - HPS RCS -A- 1505 -3P The Magnuform III Series offers an aesthetically -styled rectangular housing with sharp cutoff for a variety of distributions for any lighting application. With a wide range Of optical assemblies the RCS Series is ideal for shopping centers, parking areas, malls, commercial and industrial complexes, roadway, or any area where luminaire styling contributes to the visual environment. The RCS unit is available in 100 -400 waft HPS and 175 -400 Metal Halide. Housing - Lightweight, rugged one -piece formed and welded aluminum insures smooth construction and weatherproof integrity. The luminaire is pre- drilled for mounting to pole or wall. Ballast - 1 BO °C insulation, -20 °F starting )-40 °F, HPS), 60 Hz HPF ballast. 50 Hz ballast available - contact factory. Lens Door Frame - Extruded frame with rigid corner bracing and die -cast zinc latches to permit tool -less entry for servicing. The door has high quality silicone gasketing to seal against entry of insects, din and moisture. D I ' ecorative silkscreening provides for concealment of DIMENSIONS O sp. e ectncal compartment. I� Lens - Flat, tempered and impact resistant glass. LEKTROCOTE® Finish - Two mils minimum of .2' electrostatically applied powder coating, high temperature ,__.._26' RLGIIOF_WAY bonded to the surface for maximum adherence and finish no mmt in. s' UTILITY hardness. Standard finishes are bronze, black, gray and EASEMENT white. See ordering information. S' _ Additional Features - Full EASEMENT operation. U.L. 1572 listed and suitable for wetllocati locations, -- C.S.A. certified for outdoor use. IP suitability - IP55. �- lssi /nm1 SECTION B -B 70 l. N.T.S. oe WAS /r'V 1 _ pr 1 ee' RIGHT of WAY w- 221 G,. 1 J LJ IPjamml 3o'E %. RIGHT oF_ WAY_ __ ___. , a§'. TEDICATIMI 1 STATto We LINE 34' PLANTER b, SDEWALK rGy-I6 -,.7- rwASA 01 /01!96 J S BUILT SECTION C -C N.T.S. I 110PAI'd nGCU_AI imi ...�., .,- 331