HomeMy WebLinkAboutT-225301STREET LIGHTING NOTES
1. ALL WORK SHALL BE IN ACCORDANCE WITH THE CITY OF RENTON
STANDARD SPECIFICATIONS AND THESE PLANS AND THE LATEST
EDITION OF THE STANDARD SPECIFICATIONS FOR ROAD, BRIDGE,
AND MUNICIPAL CONSTRUCTION BY WSDOT AND APWA
WASHINGTON STATE CHAPTER. IT IS THE RESPONSIBILITY OF
THE CONTRACTOR TO OBTAIN COPIES OF THESE DOCUMENTS. IN
THE CASE OF CONFLICTS, THE STANDARDS AND SPECIFICATIONS
OF THE CITY OF RENTON SHALL BE USED.
2. THE LOCATIONS OF FEATURES SHOWN ARE APPROXIMATE AND
SHALL BE VERIFIED IN THE FIELD BY THE CONTRACTOR AS
NECESSARY. FOR UTILITY LOCATE CALL 1 -800- 424 -5555.
3. ALL MATERIALS SHALL BE NEW AND OF THE BEST AVAILABLE
GRADE OR QUALITY, EXCEPT AS NOTED. ALL EQUIPMENT
FURNISHED SHALL BE GUARANTEED AGAINST COMPONENT
FAILURE FOR A PERIOD OF ONE YEAR FOLLOWING ACCEPTANCE
BY THE CITY.
4. THE CONTRACTOR SHALL SUBMIT A REQUEST TO THE CITY OF
RENTON TRAFFIC ENGINEER FOR MATERIAL APPROVAL AT THE
EARLIEST POSSIBLE DATE.
5. ALL WORK SHALL BE CONSISTENT WITH AFFECTED UTILITY
AGENCY'S REQUIREMENTS. THE CONTRACTOR SHALL CONTACT
ALL PERTINENT UTILITY AGENCIES FORTY -EIGHT (48) HOURS
BEFORE COMMENCING WORK, AND SHALL COORDINATE THE
WORK WITH UTILITIES THROUGHOUT THE PROJECT.
6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO
EXISTING UTILITIES. THE CONTRACTOR SHALL NOTIFY THE
AFFECTED UTILITY COMPANY AND THE CITY IMMEDIATELY UPON
DAMAGE.
7. THE CONTRACTOR SHALL NOTIFY THE CITY OF RENTON
CONSTRUCTION ENGINEERING DIVISION AT 277 -5570 FOR
INSPECTION PURPOSES TWENTY -FOUR (24) HOURS BEFORE
COMMENCING WORK. NO WORK SHALL BE COVERED UNTIL IT
HAS BEEN EXAMINED BY THE ENGINEER.
8. CAUTION - OVERHEAD ELECTRICAL SERVICE LINES ARE NOT
SHOWN ON THE DRAWINGS. THE CONTRACTOR IS RESPONSIBLE
FOR DETERMINING THE EXTENT OF ANY HAZARD CREATED BY
OVERHEAD ELECTRICAL POWER IN ALL AREAS AND SHALL
FOLLOW PROCEDURES DURING CONSTRUCTION AS REQUIRED BY
LAW AND REGULATIONS AND TAKE PRECAUTIONS THAT MAY BE
REQUIRED. MINIMUM CLEARANCE FROM OVERHEAD POWER TO
THE STREET LIGHT STANDARDS IS 10 TO 16 FEET, DEPENDING ON
VOL TA GE.
9. MAINTAIN CLEARANCES FROM SUCH FEATURES SUCH AS
PROPERTY LINES, LOCATION OF DRIVEWAYS, FIRE HYDRANTS AND
ANY OTHER FEATURES. MINIMUM CLEARANCE FROM DRIVEWAYS
SHALL BE 10 -FEET, MINIMUM CLEARANCE FROM CURB 30- INCHES.
10. ALL CONDUCTORS FOR STREET LIGHTING SHALL HAVE TYPE USE -RHH
(XLP) INSULATION. CONDUCTOR INSULATION FOR PHOTO CELL
CIRCUIT SHALL BE THHN.
11. CONTINUITY AND MEGGER TESTS SHALL BE CONDUCTED AND
ANY DEFECTS NOTED SHALL BE CORRECTED BEFORE FINAL
ACCEPTANCE OF THE ELECTRICAL SYSTEM FOR STREET LIGHTS.
12. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL
COORDINATION WITH THE POWER COMPANY FOR SERVICE WORK.
THE CONTRACTOR SHALL PROVIDE AND INSTALL ALL MATERIAL NOT
PROVIDED BY THE POWER COMPANY.
13. NO HANDHOLES, POLES, OR JUNCTION BOXES SHALL BE LOCATED
WITHIN THE SIDEWALK.
14. ALL STREET LIGHTING CONDUIT SHALL HAVE A MINIMUM OF 24
INCHES OF COVER.
15. THE CONTRACTOR SHALL PROVIDE AS BUILT DRAWINGS AT
COMPLETION OF PROJECT.
LEGEND ® STREET LIGHT CONTACTOR CABINET
AND FOUNDATION (NON- METERED)
COBRA HEAD STYLE LUMINAIRE, ARM
�( AND ALUMINUM DAVIT STYLE POLE ® STREET LIGHT CONTACTOR CABINET
AND FOUNDATION (METERED)
BOX STYLE LUMINAIRE, ARM
AND ALUMINUM POLE B TYPE 1 JUNCTION BOX WITH
CONCRETE PAD
� CONCRETE PAD LIGHT BASE AND
TYPE 1 JUINC HON BOX A WIRE NOTE
- - - - PVC CONDUIT (SEE WIRING SCHEDULE) O CONSTRUCTION NOTE
CONSTRUCTION NOTES
1O INSTALL FOUNDATION AND NON- METERED STREET LIGHT CONTACTER CABINET
AT STA. 54 +88, 29.5' RT. PER STANDARD DETAILS.
OINSTALL FOUNDATION AND METERED STREET LIGHT CONTACTOR CABINET AT STA. 11 +98, 18.5' LT.
THE CABINET SHALL BE SKYLINE ELECTRIC SERIES #47700.
O3 INSTALL TWO 2" PVC (SCHED. 80) CONDUIT RISERS ON EXISTING UTILITY POLE WITH STANDOFF BRACKETS
TO TEN FEET ABOVE GRADE. INSTALL SERVICE CONDUCTORS AND COIL ADDITIONAL 25' OF CONDUCTORS
AT TOP OF RISER. COORDINATE FOR SERVICE CONNECTION BY PSP &L.
POLE SCHEDULE
POLE
NO.
POLE
ID NO.
POLE
LOCATION
POLE
OFFSET
LAMP
WATTAGE
MOUNTING
HEIGHT
MAST
ARM
SERVICE
CIRCUIT
NO.
REMARKS
1
2525F
55 +83
28.5' RT.
250
35'
8'
CITY
1
TALBOT RD. S.
2
2527F
54 +11
28.5' RT.
250
35'
8'
CITY
1
TALBOT RD. S.
3
2529F
52 +40
28.5' RT.
250
35'
8'
CITY
1
TALBOT RD. S.
4
P7014K
0 +53
18.5' RT,
100
18'
0.5'
PRIVATE
1
S. 47TH ST.
5
P7013K
1 +69
26.5' LT.
1 100
18'
0.5'
PRIVATE
1
S. 47TH ST.
6
P7012K
2 +65
18.5' RT.
100
18'
0.5'
PRIVATE
1
S. 47TH ST.
7
P7011K
3 +79
18._' LT.
100
18'
0.5'
PRIVATE
1
S. 47TH ST.
8
P7009K
4 +90
18.: ' LT.
100
18'
0.5'
PRIVATE
1
S. 47TH ST.
9
P7007K
6 +00
18.5' RT.
100
18'
0.5'
PRIVATE
1
MORRIS AVE. S.
10
P7005K
7 +09
18. F' RT.
100
18'
0.5'
PRIVATE
1
MORRIS AVE. S.
11
P7004K
8 +31
18.t LT.
1 100
18'
0.5'
PRIVATE
1
S. 46TH PL.
12
P7002K
9 +48
18.5' LT.
100
18'
0.5'
PRIVATE
1
S. 46TH PL.
13
P7001K
10 +43
18.5' RT.
100
18'
0.5'
PRIVATE
1
S. 46TH PL.
14
P7000K
11 +57
18.5' LT.
100
18'
0.5'
PRIVATE
1
S. 46TH PL.
WIRING SCHEDULE
RUN
NO.
CONDUIT
CONDUCTORS
Z
2" PVC (SCHEDULE 80)
3 - #2 SERVICE
22
1.5" PVC (SCHEDULE 40)
2 - #10, 3 - #12, 1 - #6 BARE
Z3
1.5" PVC (SCHEDULE 40)
2 - #10
A4
1.5" PVC (SCHEDULE 40)
2 - #10, 1 - #6 BARE
A5
1.5" PVC (SCHEDULE 80)
2 - #10
A6
2" PVC (SCHEDULE 40)
2 - #10, 3 - #12
Z7
2" PVC (SCHEDULE 40)
2 - #10
A2"
PVC (SCHEDULE 80)
2 - #10
2" PVC (SCHEDULE 40`
SPARE WITH PULLSTRING
7Ro -,0,* " ',?
If r r r _I I _AI r
19 18 17 16 15 14 13 12 11 10 9 8 7 6
R 148�%
GENERAL NOTES
1. SEE SPECIFICATIONS DOCUMENT FOR
PRIVATE STREET LIGHTING SYSTEM EQUIPMENT.
TRANSPORTATION PLANNING
& ENGINEERING, INC.
2101 -112TH AVENUE NORTHEAST, SUITE 110
BELLEVUE, WASHINGTON 98004
TEL. (206) 455 -5320 FAX (206) 4j3 -7180
La dSrnying
Land Use Planning A
Landscape Amhft ct-
W
a
o Z
O ® _
;v
a 2C4
Z
� Q
J
0 3
Z
rWY D O 2
LL LL
O °II°'
� Q
} w
U�
a
a
a
T.2,253
OPr� wASVy NCF
ti c
y �
16615
MAIL
RfC /STERF'�
EXPIRES 9/5/97
FOR APPROVAL
By
Ske D.,
2
O
2
'x
1
® j
M®
V
i
j
1
MARTIN
'Z of wASV,,�c�
may° o�
r
30730
RfCI STEIIFP
aNI�E� 8 -s -96
EXPIRES 01/31/97
STAMP NOT VALM
UNLESS SIGNED AND DATED
JOB M&IBER
95 -202 _
SNSETNUMBER
30 35�
1 i I I I i l i i Ii i i I I I T1
6 7 8 9 10 11 12 13 14 15 16 17 18 19