HomeMy WebLinkAboutT-226508� e .
7
r
I .
7 ^ -It -JW
L- J
P: \C ADD \DGN\ 93010- 20\HO- PC �.DGN
ISTEA PROJECT- MO- 0900('JO7)
TIA PROJECT" 9P- 102(006)-I
0
6
O PAVEMENT MARKINGS LEGEND I TH1s SHEET)
�a
1 DOUBLE YELLOW, TYPE I AND TYPE 2d LANE MARKERS
X 2 WHITE, LANE LINE, TYPE I AND TYPE 2e LANE MARKERS
X 3 DOUBLE WHITE, TYPE I AND TYPE 2e LANE MARKERS
YELLOW TWO WA LEFT TURN LINE, TYPE I AND TYPE 20 LANE MARKERS --
5 DOUBLE YELLOW, 6" SOLID PAINT LINES
6 WHITE, THERMOPLASTIC DIRECTIONAL ARROW
7 WHITE, 24" THERMOPLASTIC STOP BAR o
8 WHITE, THERMOPLASTIC CROSSWALK, 10' WIDTH
9 WHITE, 4" SOLID PAINT LINE
10 YELLOW, 4" SOLID PAINT LINE
It WHITE, TYPE I LANE MARKERS 2' ON CENTER
12 WHITE, TYPE I LANE MARKER ISLAND W/ CROSSHATCHING (SEE DETAIL ON SHEET 31)
13 DOUBLE WHITE, SKIP APPROACH LINE, TYPE I AND TYPE 2e LANE MARKERS
14 WHITE, THERMOPLASTIC TYPE 2 PREFERENTIAL LANE SYMBOL
YELLOW. TYPE I LANE MARKER ISLAND CROSSHATCHING (SEE DETAIL ON SHEET 31) -
C) SIGNING LEGEND
I REMOVE EXISTING "R3 -7" SIGN.
2 REMOVE F_X!STING "W9 -2" SIGN.
3 INSTAL! NEW "'N4 -3" SIGN AND POST AT H -10 *96 BACK 2' CLEAR OF NEW CURB.
4 INSTALL NEW "R5 -IOC" SIGN AND POST AT H -II.00 BACK 2' CLEAR OF NEW CURB.
❑ ILLUMINATION CONSTRUCTION NOTES
1 INSTALL GENERAL ELECTRIC M -250A2 POWR /DOOR LUMINAIRE WITH MEDIUM TYPE ll!
CUTOFF OPTICS, 250 WATT HIGH PRESSURE SODIUM LAMP, 35' MOUNTING HEIGHT,
AND MOUNT ON RETAINING WALL I (SEE SHEET 43 FOR DETAIL).
2 INSTALL TYPE I JUNCTION BOX P INSIDE OF BACK OF SIDEWALK.
3 REMOVE EXISTING LUMINAIRE, POLE, AND FOUNDATION.
4 REMOVE EXISTING JUNCTION BOX.
GENERAL ILLUMINATION NOTES
1 CONSTRUCT CONCRETE PAD FOR PROPOSED STREET LIGHTING AND JUNCTION BOX PER
CITY OF RENTON STANDARD PLAN J014 AND J015.
2 ALL PROPOSED ILLUMINATION CONDUIT RUNS (TRENCH) SHALL BE LOCATED 2' FROM
BACK OF CURB.
3 REFER TO SIGNAL PLANS FOR ILLUMINATION AND INTERCONNECT COUNDUIT AT
SIGNALIZE INTERSECTION.
4 ALL LUMINAIRES TO BE REMOVED SHALL BE FIRST DE- ENERGIZED AT THE SOURCE AND THEN
REMOVE ALL EXISTING LIGHTING WIRING. COORDINATE WITH CITY OF RENTON, TRAFFIC DIVISION.
5 CONSTRUCT LIGHTING UNDERGROUND SYSTEM PER CITY OF RENTON STANDARD PLAN J007.
CONDUIT AND WIRING SCHEDULE
RUN
NO.
LCONDUIT
HOUSER WAY N.
BRONSON WAY NORTH TO NORTH 8th STREET
CONDUCTORS
I
/V2" PVC SCH 40
2 -•8, 1-•8 GROUND
2
J
1Y2" PVC SCH 40
2-•8
�
31/ f?GS
�1 -O
RECORD DRAVANG NOTATIONS
These record draw,no,s reflect certain
inens�o�
and Icn
ec dd a IIn _
"l- :IV
- !eItfled b'/ Er Entranco is ,,.>t
:esponsibie far h; a.:'::,;rz:;;, apprapriztcnesc .?i
�cmple4eness of Fsuch information depicted In thF:.�,
:cord dra,,nq �otat:ans.
20 IO 0 20 40
SCALE: I " -20'
E N T R A N C
EWINEERS , SCIENTISTS - PLANNERS SURVEYORS _._- _... -. - -. _....
WASHINGTON ARIZONA CALIFORNIA
REVISION
/4-f3 ; T- 226ra8
RO C
F WAsy oo
ti
t
0 36 a
RFC I ST ER�"� rem
�SS'ONAL ENS`
CITY OF RENTON
PLANNING /BUILDING /PUBLIC WORKS DEPARTMENT
HOUSER WAY N.
BRONSON WAY NORTH TO NORTH 8th STREET
CHANNELIZATION, SIGNING, AND
ILLUMINATION PLAN
H -10 +01 TO H -13 +00
UPII 4S q
DESIGNED: IV=
DRAWN: M
DATE: MAR. 21,1995 FILE NAME:
I / I
CHECKED:
'
SCALE: Al SHOWN P -D Boat: PaDE:
BY
APPR.
DATE
APPROVED:
—ssw.m.nu SHEET: 34 OF:94
ry�u�
x ( 1
g a./
o
oa
�C
r lv
0
a
y
oz