Loading...
HomeMy WebLinkAboutT-22650At 3 z 'I +1 � 1 i B t ; m 4z1, AN-19 R / I I `F T (� ) SE 114, SEC 23, F'1�23 N, R 5,' E, W.M. e Q0 T '+ .¢P y10) o ) P, \CARD .DGNI93010- 20\H0 -PC 7.DGN 0 PAVEMENT MARKINGS LEGEND THIS SHEET) ISTEA PROJECT' DPU-007607 I DOUBLE YELLOW, TYPE 1 AND TYPE 2d LANE MARKERS 2 WHITE, LANE LINE, TYPE I AND TYPE 2e LANE MARKERS 2 3 DOUBLE WHITE, TYPE / AND ,TYPE Ze LANE MARKERS 4 YELLOW TWO WAY LEFT TURN LINE, TYPE ! AND TYPE 2d LANE MARKERS 5 DOUBLE YELLOW, 6" SOLID PAINT LINES I >x` 6 —1 IHEHMOPLASTIC DIRECTIONAL ARROW AF 7 WHITE, 24" THERMOPLASTIC STOP BAR 8 WHITE, THERMOPLASTIC CROSSWALK, 10' WIDTH 9 ..HITS, + SOLID PAINT LINE Ar 10 YELLOW, 4" SOLID PAINT LINE II WHITE, TYPE 1 LANE MARKERS 2' ON CENTER A1° 12 WHITE. TYPE / LANE MARKER ISLAND W/ CROSSHATCHING (SEE DETAIL ON SHEET 3/) 13 DOUBLE WHITE, SKIP APPROACH LINE, TYPE I AND TYPE 2e LANE MARKERS 14 WHITE, THERMOPLASTIC TYPE 2 PREFERENTIAL LANE SYMBOL I5 YELLOW, TYPE I LANE MARKER ISLAND CROSSHATCHING (SEE DETAIL ON SHEET 31) O SIGNING LEGEND I INSTALL NEW "R2 -1 (30 MPH" SIGN AND POST AT H -17.50 BACK 2' CLEAR OF NEW CURB. 2 INSTALL NEW "R3 -6R" SIGN ON TO EXISTING LUMINAIRE. 3 INSTALL NEW "R5- 10'c "M0D.S16#ePOST AT H -18 +33 BACK 2' CLEAR OF NEW SHOULDER. 4 INSTALL NEW "R5 -IOC SIGN AND POST AT SB- IO2 +64 (20' LT.). 5 , VSTALL NEW "R5 -IOC" SIGN AND POST AT SS- 108 *50 BACK 2' CLEAR OF NEW CURB. 6 RELOCATE EXISTING 'RI-2" SIGN ON TO NEW POST AT SS- 108.99 (10' RT.). ❑ ILLUMINATION CONSTRUCTION NOTES I INSTALL GENERAL ELECTRIC M -25OA2 POWR /DOOR LUMINAIRE WITH MEDIUM TYPE Nl CUTOFF OPTICS, 250 WATT HIGH PRESSURE SODIUM LAMP, 35' MOUNTING HEIGHT, AND FIXED BASE TYPE. INSTALL TYPE I JUNCTION BOX ADJACENT TO LUMINAIRE PER CITY OF RENTON STANDARD PLAN J008. FOR CONCRETE PAD 0 SIDEWA _K, SEE SHEET 27 FOR DETAIL. 2 INSTALL GENERAL ELECTRIC M -250A2 POWR /DOOR LUMINAIRE WITH MEDIUM TYPE Iii CUTOFF OPTrCS, 250 WATT HIGH PRESSURE SODIUM LAMP, 35' MOUNTING HEIGHT, AND FIXED BASE TYPE. INSTALL TYPE ! JUNCTION BOX ADJACENT TO LUMINAIRE PER CITY OF RENTON STANDARD PLAN J008. 3 THE UNDERGROUND ERVICE CONDUIT SHALL BE EXTENDED SERVICE POLE WITH A 3 -INCH GALVANIZED RIGID STEE OW GRADE AT OF THE POLE, AND A 3 -INCH GALVANIZED RIGID STEEL VERTICAL CONDUIT Rl XIMATELY 30 FEET, INSTALLED AS DIRECTED BY PUGET POWER. THE SERVICE CO L BE TERMIN WEATHERHEAD AND WITH SUFFICIENT CONDUCTOR L NO THE WEATHERHEAD FOR CONNECT/ T POWER TECHNICIANS T ET POWER TRANSFORMER. PUGET POWER SERVICE AGREEMEN A4301. GENERAL ILLUMINATION NOTES I CONSTRUCT CONCRETE PAD FOR PROPOSED STREET LIGHTING AND JUNCTION BOX PER CITY OF RENTON STANDARD PLAN J014 AND J015. 2 ALL PROPOSED ILLUMINATION CONDUIT RUNS (TRENCH) SHALL BE LOCATED 2' FROM PACK OF CURB. 3 REFER TO SIGNAL PLANS FOR ILLUMINATION AND INTERCONNECT COUNDUIT AT SIGNALIZE INTERSECTION. 4 ALL LUMINAIRES TO BE REMOVED SHALL BE FIRST DE- ENERGIZED AT THE SOURCE AND THEN REMOVE ALL EXISTING LIGHTING WIRING „COORDINATE WITH CITY OF RENTON, TRAFFIC DIVISION. 5 CONSTRUCT LIGHTING UNDERGROUND STEM PER CITY OF RENTON STANDARD PLAN. J007. `.. sE� syr. Focizc CGw/✓�aT� ��flN ® .4SB Q� a 1 g to � 6 / T9 ` l2 NO 4 RUN NO. CONDUIT CONDUCTORS I I%2" PVC SCH 40 2 -•8, 1 -•8 GROUND 2 f 2 -•8 3 3" PVC -CT. RGS l ✓ / CHECKED: SCALE: AS SHOWN / RY APPR. C APPROVEDt / A / I I `F T (� ) SE 114, SEC 23, F'1�23 N, R 5,' E, W.M. e Q0 T '+ .¢P y10) o ) P, \CARD .DGNI93010- 20\H0 -PC 7.DGN 0 PAVEMENT MARKINGS LEGEND THIS SHEET) ISTEA PROJECT' DPU-007607 I DOUBLE YELLOW, TYPE 1 AND TYPE 2d LANE MARKERS 2 WHITE, LANE LINE, TYPE I AND TYPE 2e LANE MARKERS 2 3 DOUBLE WHITE, TYPE / AND ,TYPE Ze LANE MARKERS 4 YELLOW TWO WAY LEFT TURN LINE, TYPE ! AND TYPE 2d LANE MARKERS 5 DOUBLE YELLOW, 6" SOLID PAINT LINES I >x` 6 —1 IHEHMOPLASTIC DIRECTIONAL ARROW AF 7 WHITE, 24" THERMOPLASTIC STOP BAR 8 WHITE, THERMOPLASTIC CROSSWALK, 10' WIDTH 9 ..HITS, + SOLID PAINT LINE Ar 10 YELLOW, 4" SOLID PAINT LINE II WHITE, TYPE 1 LANE MARKERS 2' ON CENTER A1° 12 WHITE. TYPE / LANE MARKER ISLAND W/ CROSSHATCHING (SEE DETAIL ON SHEET 3/) 13 DOUBLE WHITE, SKIP APPROACH LINE, TYPE I AND TYPE 2e LANE MARKERS 14 WHITE, THERMOPLASTIC TYPE 2 PREFERENTIAL LANE SYMBOL I5 YELLOW, TYPE I LANE MARKER ISLAND CROSSHATCHING (SEE DETAIL ON SHEET 31) O SIGNING LEGEND I INSTALL NEW "R2 -1 (30 MPH" SIGN AND POST AT H -17.50 BACK 2' CLEAR OF NEW CURB. 2 INSTALL NEW "R3 -6R" SIGN ON TO EXISTING LUMINAIRE. 3 INSTALL NEW "R5- 10'c "M0D.S16#ePOST AT H -18 +33 BACK 2' CLEAR OF NEW SHOULDER. 4 INSTALL NEW "R5 -IOC SIGN AND POST AT SB- IO2 +64 (20' LT.). 5 , VSTALL NEW "R5 -IOC" SIGN AND POST AT SS- 108 *50 BACK 2' CLEAR OF NEW CURB. 6 RELOCATE EXISTING 'RI-2" SIGN ON TO NEW POST AT SS- 108.99 (10' RT.). ❑ ILLUMINATION CONSTRUCTION NOTES I INSTALL GENERAL ELECTRIC M -25OA2 POWR /DOOR LUMINAIRE WITH MEDIUM TYPE Nl CUTOFF OPTICS, 250 WATT HIGH PRESSURE SODIUM LAMP, 35' MOUNTING HEIGHT, AND FIXED BASE TYPE. INSTALL TYPE I JUNCTION BOX ADJACENT TO LUMINAIRE PER CITY OF RENTON STANDARD PLAN J008. FOR CONCRETE PAD 0 SIDEWA _K, SEE SHEET 27 FOR DETAIL. 2 INSTALL GENERAL ELECTRIC M -250A2 POWR /DOOR LUMINAIRE WITH MEDIUM TYPE Iii CUTOFF OPTrCS, 250 WATT HIGH PRESSURE SODIUM LAMP, 35' MOUNTING HEIGHT, AND FIXED BASE TYPE. INSTALL TYPE ! JUNCTION BOX ADJACENT TO LUMINAIRE PER CITY OF RENTON STANDARD PLAN J008. 3 THE UNDERGROUND ERVICE CONDUIT SHALL BE EXTENDED SERVICE POLE WITH A 3 -INCH GALVANIZED RIGID STEE OW GRADE AT OF THE POLE, AND A 3 -INCH GALVANIZED RIGID STEEL VERTICAL CONDUIT Rl XIMATELY 30 FEET, INSTALLED AS DIRECTED BY PUGET POWER. THE SERVICE CO L BE TERMIN WEATHERHEAD AND WITH SUFFICIENT CONDUCTOR L NO THE WEATHERHEAD FOR CONNECT/ T POWER TECHNICIANS T ET POWER TRANSFORMER. PUGET POWER SERVICE AGREEMEN A4301. GENERAL ILLUMINATION NOTES I CONSTRUCT CONCRETE PAD FOR PROPOSED STREET LIGHTING AND JUNCTION BOX PER CITY OF RENTON STANDARD PLAN J014 AND J015. 2 ALL PROPOSED ILLUMINATION CONDUIT RUNS (TRENCH) SHALL BE LOCATED 2' FROM PACK OF CURB. 3 REFER TO SIGNAL PLANS FOR ILLUMINATION AND INTERCONNECT COUNDUIT AT SIGNALIZE INTERSECTION. 4 ALL LUMINAIRES TO BE REMOVED SHALL BE FIRST DE- ENERGIZED AT THE SOURCE AND THEN REMOVE ALL EXISTING LIGHTING WIRING „COORDINATE WITH CITY OF RENTON, TRAFFIC DIVISION. 5 CONSTRUCT LIGHTING UNDERGROUND STEM PER CITY OF RENTON STANDARD PLAN. J007. `.. sE� syr. Focizc CGw/✓�aT� ��flN ® .4SB Q� a 1 g to � 6 / T9 ` l2 NO 4 74x3; 7'- 2265`0,4 CONDUIT AND WIRING SCHEDULE RUN NO. CONDUIT CONDUCTORS I I%2" PVC SCH 40 2 -•8, 1 -•8 GROUND 2 /J2" PVC SCH 40 2 -•8 3 3" PVC -CT. RGS 6 / CHECKED: SCALE: AS SHOWN / RY APPR. DATE APPROVEDt / RECORD r C / /A/Ci'T JVIrJ� i R/ Ilia A/ 1/ sP soon uA - ►ems• ir•�y T T The -e recc d =- - / dim¢1SLons de -- / r¢(•"Qd drawings v�h Chh t n'rd pen�'er -ly responsible for the 2,,....rai p ` 'e —l' 01 Completeness of such inforrnat o0 deoic,—d m th- record drawing notations 20 10 0 20 40 SCALE. 1" -20' E N T R A N C O _ ENGINEERS SCIENTISTS PLANNERS • SURVEYORS p WACA" —TGN ARIZONA CALIFORMA REVISION 74x3; 7'- 2265`0,4 CONDUIT AND WIRING SCHEDULE RUN NO. CONDUIT CONDUCTORS I I%2" PVC SCH 40 2 -•8, 1 -•8 GROUND 2 /J2" PVC SCH 40 2 -•8 3 3" PVC -CT. RGS 3 -•1 10 Tm 2266f)A �NO F WASy' .el CITY OF RENTON ,n PLANNING /BUILDING /PUBLIC WORKS DEPARTMENT ROUSER WAY N. 20 36 RFC ISt ER4,'"� �ss'oNAI ENS` EkPIPES a .� BRONSON WAY NORTH TO NORTH 8th STREET CHANNELIZATION, SIGNING, & ILLUM. PLAT H -17 +00 TO H -21 +00 SS -- 107 +00 TO SR900 -35 +50 DESIGNED: �I DRAWN: DATE: MAR. 21. 1995 FILE NAME: CHECKED: SCALE: AS SHOWN FELD @DOG, PACE: RY APPR. DATE APPROVEDt SHEET: 36 OF: 94 7 0 m ham+ z o lv a z R II ` N h` Lp) e .