HomeMy WebLinkAboutT-26900E11 LUMINAIRE SCHEDULE SERVICE NO. 896 LUMINAIRE NUMBER CIRCUIT LOCATION TYPE - DISTRIBUTION- WATTAGE MAST ARM H1 BASE TYPE COMMENTS STATION OFFSET 174 E EXISTING EXISTING I11 -MED CUTOFF -400 HPS 10' 50 SLIP FIXED 175 E EXISTING EXISTING III -MED CUTOFF -400 HPS 10' 50 SLIP FIXED X -1 E EXISTING EXISTING 111 -MED CUTOFF -400 HPS 16' 50 SLIP FIXED 163 E EXISTING EXISTING III -MED CUTOFF -400 HPS 16' 50 SLIP FIXED 164 E EXISTING EXISTING I11 -MED CUTOFF -400 HPS 10' 50 SLIP FIXED X -3 F EXISTING E405 1120 +91 III -MED CUTOFF -400 HPS 10' 50 SLIP BARRIER X-4 F EXISTING E405 1123 +69 111 -MED CUTOFF -400 HPS 10' 50 SLIP BARRIER 165 F EXISTING E405 1126 +22 111 MED CUTOFF -400 HPS 10' 50 SLIP BARRIER 166 -167 E EXISTING E405 1128 +89 111 -MED CUTOFF -400 HPS 8' 50 FIXED BARRIER 101 -102 B EXISTING E405 1131 +59 III -MED CUTOFF -310 HPS 4' 50 EXISTING SHOEBOX 103 -104 B EXISTING 1405 1134 +31 III -MED CUTOFF - 310 HPS 4' 50 EXISTING SHOEBOX 105 -106 B EXISTING 1405 1136 +62 III -MED CUTOFF -310 HPS 4' 50 EXISTING SHOEBOX 107 -108 B EXISTING 1405 1138 +23 111 -MED CUTOFF -310 HPS 4' 50 EXISTING SHOEBOX 1N F E405 1087 +22 124.00' RT I11 -MED CUTOFF -400 HPS 12' 50 BARRIER BARRIER MOUNTED,SHOEBOX 2N F E405 1090 +46 1405 1142 +58 III -MED CUTOFF -400 HPS 12 50 FIXED SHOEBOX 3N F E405 1093 +14 84.50' RT III -MED CUTOFF -400 HPS 12' 50 FIXED SHOEBOX 109 -110 B EXISTING 51.00' RT III -MED CUTOFF -310 HPS 4' 50 EXISTING SHOEBOX 111 -112 A EXISTING 39.00' LT I11 -MED CUTOFF -310 HPS 4' 50 EXISTING SHOEBOX 113 -114 A EXISTING 111 -MED CUTOFF -310 HPS 4' 50 EXISTING SHOEBOX 115 A EXISTING 91.00' RT III -MED CUTOFF -400 HPS 12' 50 SLIP SHOEBOX 116 A EXISTING 83.00' RT ill -MED CUTOFF -400 HPS 12' 50 SLIP SHOEBOX 4N F E405 1095 +76 81.00' RT III -MED CUTOFF -400 HPS 12' 50 FIXED SHOEBOX 5N F E405 1098 +36 81.00' RT III -MED CUTOFF -400 HPS 12' 50 BARRIER BARRIER MOUNTED,SHOEBOX 6N F E405 1101 +23 80.00' RT ill -MED CUTOFF -400 HPS 12' 50 BARRIER BARRIER MOUNTED,SHOEBOX 13 A EXISTING UNDERDECK - 100 S NA 18 1 UD A E405 1104 +14 62.00' LT UNDERDECK - 1 # CWA NA 18 2UD A E405 1104 +14 1.00' LT UNDERDECK - 10 CWA NA 18 3UD A E405 1104 +14 1.00' RT UNDERDECK - 10 CWA NA 18 4UD A E405 1104 +14 50.00' RT UNDERDECK - 10 CWA NA 18 5UD A E405 1104 +53 50.00' RT UNDERDECK - 1 0 CWA NA 18 N���k LUMINAIRE SCHEDULE SERVICE NO. 1235 LUMINAIRE NUMBER CIRCUIT LOCATION TYPE - DISTRIBUTION- WATTAGE TYPE- DISTRIBUTION- WATTAGE ARM H1 BAS STATION STATION OFFSET 201 -202 A EXISTING 111 -MED CUTOFF -400 HPS III -MED CUTOFF -310 HPS 4' 50 FIXED SHOEBOX 203 -204 A EXISTING III -MED CUTOFF -400 HPS 111 -MED CUTOFF -310 HPS 4' 50 FIXED SHOEBOX 205 -206 A EXISTING III -MED CUTOFF -400 HPS I11 -MED CUTOFF -310 HPS 4' 50 FIXED SHOEBOX 207 -208 A EXISTING III -MED CUTOFF -400 HPS III -MED CUTOFF -310 HPS 4' 50 FIXED SHOEBOX 209 -210 B EXISTING III -MED CUTOFF -400 HPS III -MED CUTOFF -310 HPS 4' 50 FIXED SHOEBOX 1M-2M B E405 1120 +91 0.47' LT 111 -MED CUTOFF -400 HPS 4' 50 BARRIER BARRIER MOUNTED,SHOEBOX 3M-4M B E405 1123 +69 0.99' RT III -MED CUTOFF -400 HPS 4' 50 BARRIER BARRIER MOUNTED,SHOEBOX 5M -6M B E405 1126 +22 0.99' RT III -MED CUTOFF -400 HPS 4' 50 BARRIER BARRIER MOUNTED,SHOEBOX 7M -8M B E405 1128 +89 0.99' RT 111 -MED CUTOFF -400 HPS 4' 50 BARRIER BARRIER MOUNTED,SHOEBOX 9M -10M B E405 1131 +59 1.52' RT III -MED CUTOFF -400 HPS 4' 50 BARRIER BARRIER MOUNTED,SHOEBOX 11M -12M C 1405 1134 +31 3.00' RT I11 -MED CUTOFF -400 HPS 4' 50 BARRIER BARRIER MOUNTED,SHOEBOX 13M -14M C 1405 1136 +62 4.50' RT III -MED CUTOFF -400 HPS 4' 50 BARRIER BARRIER MOUNTED,SHOEBOX 24N C 1405 1138 +23 70.60' RT III -MED CUTOFF -400 HPS 12' 50 FIXED SHOEBOX 15M -16M C 1405 1139 +83 8.00' RT III -MED CUTOFF -400 HPS 4' 50 BARRIER BARRIER MOUNTED,SHOEBOX 17M -18M C 1 1405 1142 +58 8.01' RT I11 -MED CUTOFF -400 HPS 4' 50 BARRIER BARRIER MOUNTED,SHOEBOX LUMINAIRE SCHEDULE SERVICE NO. 880 LUMINAIRE NUMBER CIRCUIT LOCATION TYPE - DISTRIBUTION- WATTAGE MAST ARM H1 BASE TYPE COMMENTS STATION OFFSET 7N A E405 1107 +54 94.00' RT 111 -MED CUTOFF -400 HPS 12' 50 SLIP SHOEBOX 8N A NB405 -SR181 + 45.00' RT III -MED CUTOFF -400 HPS 12' 50 FIXED SHOEBOX 9N A NB405 -SR18 14 +15 54.00' RT III -MED CUTOFF -400 HPS 12' 50 FIXED WALL MOUNTED,SHOEBOX 10N A SR181 -NB 0 0 44.00' RT III -MED CUTOFF -400 HPS 12' 50 SLIP SHOEBOX 11N A E40 1113 +82 102.00' RT III -MED CUTOFF -400 HPS 12' 50 SLIP SHOEBOX 2 A EXI Ak 8.00' RT III -MED CUTOFF -400 HPS 16' 50 SLIP BARRIER MOUNTED,SHOEBOX 4 A E181 19 +80.00 56.00' LT III -MED CUTOFF -250 HPS 12' 40 SLIP BARRIER MOUNTED,SHOEBOX LUMINAIRE SCHEDULE SERVICE NO. 6287 LUMINAIRE NUMBER CIRCUIT LOCATION TYPE - DISTRIBUTION- WATTAGE MAST ARM H1 BASE TYPE COMMENTS STATION OFFSET 4S A 1405 1145 +37.00 60.00' LT III -MED CUTOFF - 400 HPS 12' 50 BARRIER BRIDGE MOUNTED,SHOEBOX 12N A 1405 1145 +37.00 64.00' RT III -MED CUTOFF -400 HPS 12' 50 BARRIER BRIDGE MOUNTED,SHOEBOX 5S A 1405 1147 +78.00 63.00' LT III -MED CUTOFF -400 HPS 12' 50 BARRIER BRIDGE MOUNTED,SHOEBOX 13N A 1405 1147 +78.00 64.00' RT III -MED CUTOFF -400 HPS 12' 50 BARRIER BRIDGE MOUNTED,SHOEBOX 19M -20M A 1405 1150 +39 8.00' RT III -MED CUTOFF -400 HPS 4' 50 BARRIER BARRIER MOUNTED,SHOEBOX 21M -22M B 1405 1153 +09 8.00' RT III -MED CUTOFF -400 HPS 4' 50 BARRIER BARRIER MOUNTED,SHOEBOX 23M -24M B 1405 1155 +91 8.00' RT III -MED CUTOFF -400 HPS 4' 50 BARRIER BARRIER MOUNTED,SHOEBOX 25M -26M B 1405 1158 +80 8.00' RT III -MED CUTOFF -400 HPS 4' 50 BARRIER BARRIER MOUNTED,SHOEBOX 27M -28M B 1405 1161 +42 8.00' RT 111 -MED CUTOFF -400 HPS 4' 50 BARRIER BARRIER MOUNTED,SHOEBOX 29M -30M C 1405 1164 +09 8.00' RT III -MED CUTOFF -400 HPS 4' 50 BARRIER BARRIER MOUNTED,SHOEBOX 31 M -32M C 1405 1166 +59 8.13' RT III -MED CUTOFF -400 HPS 4' 50 BARRIER BARRIER MOUNTED,SHOEBOX 33M -34M C 1405 1169 +11 8.68' RT III -MED CUTOFF -400 HPS 4' 50 BARRIER BARRIER MOUNTED,SHOEBOX 251 -252 C EXISTING III -MED CUTOFF -310 HPS 4' 50 BARRIER BARRIER MOUNTED,SHOEBOX FILE NAME TIME DATE PLOTTED BY DESIGNED BY ENTERED BY CHECKED BY PROJ. ENGR. REGIONAL ADM. LUMINAIRE SCHEDULE EXISTING SERVICE NO.4047 LUMINAIRE NUMBER CIRCUIT LOCATION TYPE- DISTRIBUTION - WATTAGE TYPE- DISTRIBUTION - WATTAGE MAST ARM H1 BASE TYPE COMMENTS STATION OFFSET 1S A E405 1107 +84 85.00' LT III -MED CUTOFF -400 HPS 12' 50 FIXED SHOEBOX 2S A E405 1111 +62 61.00' LT I11 -MED CUTOFF - 400 HPS 12 50 SLIP SHOEBOX 3S A E4051113+99 89.00' LT III -MED CUTOFF - 400 HPS 12' 50 FIXED SHOEBOX LUMINAIRE SCHEDULE EXISTING SERVICE NO.882 LUMINAIRE NUMBER CIRCUIT LOCATION TYPE- DISTRIBUTION - WATTAGE MAST ARM H7 BASE TYPE COMMENTS STATION OFFSET 33 C EXISTING 39.00' LT UNDERDECK -100 HPS N/A 16 FIXED SHOEBOX 34 C EXISTING D. FRANKUM UNDERDECK - 100 HPS N/A 16 FIXED SHOEBOX 14N C NB405 -NBCD 25 +13 34.00' RT 111 -MED CUTOFF -400 HPS 12' 50 BARRIER BARRIER MOUNTED,SHOEBOX 15N C NB405 -SB167 10 +62 24.00' RT 111 -MED CUTOFF -400 HPS 12' 50 BARRIER BARRIER MOUNTED,SHOEBOX 16N C NB405 -SB167 12 +97 27.00' RT III -MED CUTOFF -400 HPS 12' 50 FIXED SHOEBOX 17N C E405 1180 +44 96.00' RT III -MED CUTOFF -400 HPS 12' 50 SLIP SHOEBOX 18N C E4051183+09 125.00' RT 111 -MED CUTOFF - 400 HPS 12' 50 FIXED SHOEBOX 60 D EXISTING III -MED CUTOFF -310 HPS 10' 40 FIXED SHOEBOX 71 D EXISTING 111 -MED CUTOFF - 250 HPS 14' 40 FIXED SHOEBOX 72 D EXISTING III -MED CUTOFF -250 HPS 16' 40 FIXED SHOEBOX 6S A SB167 -SB405 17 +69 55.00' LT III -MED CUTOFF -400 HPS 12' 50 FIXED SHOEBOX 1 A EXISTING UNDERDECK - 100 HPS N/A 16 FIXED SHOEBOX 2 A EXISTING UNDERDECK - 100 HPS N/A 16 FIXED SHOEBOX 3 A EXISTING III -MED CUTOFF - 250 HPS 12' 40 SLIP SHOEBOX 4 A EXISTING III -MED CUTOFF - 250 HPS 16' 40 SLIP SHOEBOX 7S A SB167 -SB405 20 +22 37.00' LT III -MED CUTOFF -400 HPS 12' 50 FIXED SHOEBOX 8S A SB167 -SB405 22 +27 51.00' RT III -MED CUTOFF -400 HPS 12' 50 SLIP SHOEBOX 9S A SB167 -SB405 24 +55 39.00' LT 111 -MED CUTOFF - 400 HPS 12' 50 SLIP SHOEBOX 24 B EXISTING III -MED CUTOFF -310 HPS 6' 40 FIXED 8 A EXISTING 91.00' RT III -MED CUTOFF -400 HPS 10' 50 FIXED SHOEBOX 9 B EXISTING 83.00' RT III -MED CUTOFF -400 HPS 16' 50 FIXED SHOEBOX LUMINAIRE SCHEDULE EXISTING SERVICE NO.2022 LUMINAIRE NUMBER CIRCUIT LOCATION TYPE - DISTRIBUTION- WATTAGE MAST ARM H1 BASE TYPE COMMENTS STATION OFFSET 101 -102 A EXISTING 39.00' LT III -MED CUTOFF -310 HPS 4' 50 FIXED SHOEBOX 103 -104 A EXISTING D. FRANKUM III -MED CUTOFF -310 HPS 4' 50 FIXED SHOEBOX 105 -106 A EXISTING 47.50' RT III -MED CUTOFF -310 HPS 4' 50 FIXED SHOEBOX 107 -108 A EXISTING 59.00' LT III -MED CUTOFF -310 HPS 4' 50 FIXED SHOEBOX 109 -110 B EXISTING III -MED CUTOFF -310 HPS 4' 50 FIXED SHOEBOX 111 -112 B EXISTING 56.00' LT 111 -MED CUTOFF -310 HPS 4' 50 FIXED SHOEBOX 113 -114 B EXISTING 111 -MED CUTOFF -310 HPS 4' 50 FIXED SHOEBOX 115 -116 B EXISTING III -MED CUTOFF -310 HPS 4' 50 FIXED SHOEBOX 117 -118 B EXISTING III -MED CUTOFF -310 HPS 4' 50 FIXED SHOEBOX 119 -120 C EXISTING I11 -MED CUTOFF -310 HPS 4' 50 FIXED SHOEBOX 121 -122 C EXISTING III -MED CUTOFF -310 HPS 4' 50 FIXED SHOEBOX 123 -124 C EXISTING 111 -MED CUTOFF -310 HPS 4' 50 FIXED SHOEBOX 125 -126 C EXISTING I11 -MED CUTOFF -310 HPS 4' 50 FIXED SHOEBOX 127 -128 C EXISTING 111 -MED CUTOFF -310 HPS 4' 50 FIXED SHOEBOX 129 -130 C EXISTING III -MED CUTOFF -310 HPS 4' 50 FIXED SHOEBOX 19N E E4051198+54 91.00' RT III -MED CUTOFF - 400 HPS 12' 32 FIXED SHOEBOX 20N E E405 1201 +26 83.00' RT III -MED CUTOFF -400 HPS 12' 35 FIXED SHOEBOX 21 N E E405 1204 +01 78.00' RT III -MED CUTOFF -400 HPS 12' 42.5 FIXED SHOEBOX 22N E E405 1206 +87 75.00' RT III -MED CUTOFF -400 HPS 12' 50 FIXED SHOEBOX 23N E E405 1209 +43 72.00' RT ill -MED CUTOFF -400 HPS 12' 50 FIXED SHOEBOX LUMINAIRE SCHEDULE EXISTING SERVICE NO.3302 LUMINAIRE NUMBER CIRCUIT LOCATION TYPE- DISTRIBUTION - WATTAGE MAST ARM H7 BASE TYPE COMMENTS STATION OFFSET 50 -51 A E181 18 +18 39.00' LT 111 -MED CUTOFF -400 HPS 12' 40 J. GELLINGS SIGNAL MOUNTED 52 A 1 D. FRANKUM III -MED CUTOFF -250 HPS 12' 40 K. OSWELL SIGNAL MOUNTED 53 A E181 16 +22 47.50' RT III -MED CUTOFF -250 HPS 12' 40 SLIP _ D. DYE 54 A E181 16 +87 59.00' LT III -MED CUTOFF -250 HPS 12' 40 SLIP 55 A III -MED CUTOFF -250 HPS 12' 40 SLIP 56 A E181 15 +37.50 56.00' LT III -MED CUTOFF -250 HPS 12' 40 SLIP C: XWorklProjectWiseIBTJV00021dms02269XBTJV0002 _NT IL 405- AB.dgn 2 :08 :03 PM 4 AS -BUILT 716110 JMS REGION STATE FED,AID PROJ.NO. 8/19/2010 NDC 120 - REPLACE EX. JUNCTION BOX 10/812009 JMGE 10 WAS d10 NDC 105 - LUMINAIRE RELOCATIONS 04/2712009 JMGE J. GELLINGS 1 NDC 86 - LIGHTING REVISIONS 10/31/08 JMGE JOB NUMBER D. FRANKUM IFC 5116108 JMG K. OSWELL NDC 28 - REVISIONS 51512008 KOO CONTRACT NO. 0-7295 LOCATION NO. L. HODGSON A ISSUED AT RISK 413/2008 KOO _ D. DYE REVISION DATE BY GENERAL NOTES: CONSTRUCTION NOTES D CONSTRUCT FOUNDATION PER WSDOT STANDARD PLAN 28.30.00 AND INSTALL O LIGHT STANDARD AND LUMINAIRE. USE SHOEBOX STYLE L A E. OREMOVE FOUNDATION, LIGHT STANDARD AND JUNCTION BOX. O3 REMOVE FOUNDATION AND LIGHT STANDARD. BACKFILL. �q INTERCEPT EXISTING CONDUIT AND EXTEND TO JUNCTION BOX. SPLICE CONDUCTORS TO EXISTING ILLUMINATION OR ITS CIRCUIT PER WIRING SCHEDULE. lkv�' kqml� O O O 70 71 21 22 23 O kiD�l 1. ALL CIRCUITS SHALL HAVE A GROUND CONDUCTOR. 28 2. NEW GROUND WIRE SIZE TO MATCH LARGEST WIRE SIZE WHEN REPLACING ANY CONDUCTORS IN A CONDUIT. \p,T T HEyy W A Sys 6? y CD -� cn A 43352 01- MFG I S T 01 ASS /ONAL ENG\ P.E. STAMP BOX INSTALL LIGHT r•,.r AND LUMINAIRE ON RETAINING WALL. SHOEBOX USE - PLANS - • r. • • • • •• l CITY OF RENTON ELECTRICAL SERVICE. PER CITY OF RENTON, SERVICE DOES NOT HAVE A SERVICE NUMBER. THIS SERVICE WILL BE LABELED " RENTON SERVICE #1" IN THE LUMINAIRE AND WIRING SCHEDULES. REMOVE EXISTING JUNCTION BOX. EXTEND CONDUIT TO NEW JUNCTION BOX. r . W.11 0 WIN Pj IWAI r M; 1:4:2 111111:0111 r ROUTE CONDUIT INTO EXISTING JUNCTION BOX. MAKE REQUIRED SPLICES PER WRING SCHEDULE. REMOVE EXISTING JUNCTION BOX. CONSTRUCT FOUNDATION AND INSTALL LIGHT STANDARD AND LUMINAIRE ON BRIDGE RAIL. USE SHOEBOX STYLE LUMINAIRE. SEE BRIDGE PLANS FOR FOUNDATION DETAILS. 4 CONSTRUCT FOUNDATION PER WSDOT STANDARD PLAN J-28.30.00 AND INSTALL LIGHT STANDARD AND LUMINAIRE. USE COBRA HEAD • • r 0 CONSTRUCT • r• AND INSTALL LIGHT STANDARD , AND LUMINAIRE SEE SHEET PVD7 FOR r - IER FOUNDATION DETAILS. USE SHOEBOX INSTALL UNDERDECK r - B20 & . FOR DETAILS CABINET INSTALL A PAD MOUNTED TYPE E ELECTRICAL SERVICE CABINET PER WSDOT STANDARD PLAN J-3D AND THE BREAKER SCHEDULE ON SHEET ILD2. SEALTHE BEAD OF • ROUTE CONDUIT AND CONDUCTORS FROM EXISTING NEMA JUNCTION BOX TO SIGN, LIGHT FIXTURE. SEE SHEETS SN2, SN3, BMS02 AND BMS06. CONSTRUCT r. • N PER WSDOT STANDARD - LAN J-28.30.0 AND INSTALL A rA-r AND LUMINAIRE. USE SHOEBOX STYLE LUMINAIRE. LUMINAI TED IN ECOLOGY EMBANKMENT. FOUNDATION DEPTH SHALL BE MEASURED FROM THE BOTTOM ECOLOGY SEE SHEET DD5 FOR DETAILS. INSTALL LIGHT r,.r AND LUMINAIRE ON RETAINING WALL. USE • :! WAD 10A & WAD10B • DETAILS. JUNCTION ROUTE CONDUIT AND CONDUCTORS FROM EXISTING TRAFFIC BARRIER TO TYPE 4 JUNCTION BOX IN SHOULDER. SPLICE CONDUCTORS PER WIRING SCHEDULE. REPLACE EXISTING TYPE 1 BOX AND INSTALL A TYPE 4 HEAVY DUTY JUNCTION • PER WSDOT STANDARD PLAN J-1 1 B. CONSTRUCT SAWCUT, PAVEMENT PATCH, TRENCH, AND CDF BACKFILL PER SHOULDER TRENCH DETAIL ON SHEET ITD10. REMOVE EXISTING TYPE 1 JUNCTION BOX AND INSTALL A TYPE 4 HEAVY DUTY JUNCTION BOX PER WSDOT STANDARD PLAN J-11B. LOCATE THE TYPE 4 HEAVY DUTY JUNCTION BOX AT THE FACE OF THE NEAREST TYPE 2 PRE-CAST BARRIER. SWEEP EXISTING CONDUIT AND CONDUCTORS INTO NEW TYPE 4 HEAVY DUTY JUNCTION BOX. CONSTRUCT PAVEMENT TRENCH,AND CDF BACKFILL PER SHOULDER DETAIL ON r S M. S % R A Washington State of W A Syi O,y� r Department of Transportation 0 Corridor Pro,-awarn, ONAL EN ATE P.E. STAMP BOX 1-406 1-5 TO SRI 69 -qTAr.ms= oi wins=mimn DAVID EVANS Ii.FINGEI BERC;ER AN®ASSOCIATESmc. „ 415 - 118th Avenue SE Bellevue Washington 98005 -3518 Civil inc. Phone: 425.519.6500 TRY- STATE CONSTRUCTION, INC. ILLUMINATION SCHEDULES AND NOTES e'e� 6nUadiW X1 Im SHEET 180 OF