O CONSTRUCTION NOTES:
46. Install new camera controller cabinet and other accessories required to make the CCTV system
functional per ITS Details on ITO 12 and ITO 13 and Standard Specifications. Controller cabinet
installation shall include mounting the cabinet on its foundation, terminating power Cables,
grounding the cabinet and terminating communications cables. Install video and data transmitter and
single mode fiber optic patch cord from fiber optic patch panel to transmitter.
47. Install new conduit(s) into existing junction box.
48. Trench in existing paved areas per plan Details on ITO 10. Install new NMS PVC schedule ea conduit.
49. Maintain and protect existing advance warning ramp meter pole and beacon.
50. Maintain and protect existing ES cabinet. Install a new 12 -port patch panel and terminate 1 -6 SMFO
cable from CC-617.
51. Install a new 36 -port patch panel and terminate mainline fiber distribution cable per Fiber Splice
Details.
52. Install a new 54 -port patch panel and terminate 1 -6 SMFO lateral to ES- 616R /D, existing 1 -6 SMFO
lateral to S 156th St & W Valley Hwy signal controller cabinet, and mainline distribution cable per
Fiber Splice Detials.
53. Install 2 duplex FC -LC single -mode patch cords between the patch panel in the CC cabinet and the
RMC40 switch in the VMS cabinet. Install manufactured provided VMS communication cable to VMS.
54. Install 2 duplex FC -LC single -mode patch cords between the patch panel in the CC /HAR cabinet and the
RMC40 switch in the ES cabinet.
55. Install 2 duplex FC -LC single -mode patch cords between the patch panel in the CC /HAR cabinet and the
RMC40 switch in the VMS cabinet. Install manufactured provided VMS communication cable to VMS.
56. Install new cable vault outside of paved area per WSDOT Standard Plan J -15b and Standard
Specifications. Coil and rack a minimum of 50-feet of each new cable installed in cable vault.
57. Install conduit under the existing pavement using an approved directional boring method per Special
Provisions.
66. Remove pull box. backfill, and patch to match existing pavement depth and material. Abandon
existing cable and conduits.
67. Install foundation for a double wide fiber terminal cabinet per Cabinet Foundation Details on ITD
21 and Standard Specifications.
68. Remove existing junction box and replace with new split cable vault. Maintain and protect
existing conduits and loop lead -ins to remain. Coil and rack a minimum of 50 -feet of each new
cable Installed In box.
69. See Illumination Plans for continuation of the power conductors between the ramp meter flashing
warning beacon and ES-622D cabinet.
70. Remove existing junction box and replace with a new Type 7 junction box outside of poved area per
WSOOT Standard Plan J -]lc and Standard Specifications. Maintain and protect existing conduits
and cables.
71. Pull out loop leod -in cables for - MS -X -2, AMS - - -1 and AMS --- 2 loops from existing ES -622D and
route to new ES cabinet.
72. New CCTV -611 camera is state - furnished.
73. Install new CCTV camera, cable, camera pole and foundation, and other accessories required to
make the CCTV system functional per ITS Details on ITD 11 and Standard Specifications.
74. Install new conduits into existing cable vaults. Patch entry holes with water tight seal around
new conduit upon completion of work.
T5. Install conduit stubout into paved shoulder to the traveled way side of barrier for loop
detectors installed in outside lanes.
76. Core drill existing foundation for new conduits.
77. Install foundation per Cabinet Foundation Details on ITS 28 and Standard Specifications
78
58. Remove existing cable vault and install new split cable vault with heavy duty lid oriented so the 79
south side wall of the box is flush with southern most existing mainline ITS conduit per ITS Vault
Replacement Detail on ITO 25A. Coil and rack a minimum of 50 -feet of each new cable insfolled in 80
box.
59. Intercept existing pull box with new conduit(s). Coil and rack a minimum of 50 -feet of each new
cable installed in pull box.
60. Install a new 12 -port patch panel and terminate 1 -6 SMFO cable from the FTC preterminated patch
panel stub in cable vault.
61. Install new double -wide 334 fiber terminal cabinet per ITS Details on ITO 22 and Standard
Specifications. See ITO 18 for fiber patch panel installation. Disconnect and remove communication
cables shown on the ITS Distribution Diagram on ITD 3 from the existing Renton Hub then reinstall
and reconnect in the new FTC as directed by WSDOT ITS engineer. Provide WSDOT ITS engineer 30
business days notice prior to relocating equipment.
62. Remove existing loop lead -in cable(sl and splice new loop lead -in cables) to the existing loop
wires. Maintain and protect existing junction box.
63. Splice 1 -36 SMFO to the 2 -48 SMFO distribution cables in the cable vault per Fiber Splice Details on
ITO 9 and provide splice enclosure.
64. Intercept existing condult(sl and extend or sweep with the some size and type conduit into new pull
box.
65. Remove existing cable vault. Install new split pull box oriented so the north side well of the box
is flush with northern most existing mainline ITS conduit entering from the west per ITS Vault
Replacement Detail on ITD 24. Extend all conduits (except the five that route into the barrier
which can be abandoned) from the existing cable vault into the new pull box. Innerducts in the 2 -3"
mainline ITS conduits entering from the east do not need to be extended. These conduits will be
abandoned at the end of the project. Poo ll and patch to match existing pavement depth and
material around the new pull box. Coil and rack a minimum of 50-feet of each new cable installed in
box.
P =
Intercept existing 2.5" conduit to ES -612D cabinet and sweep into new junction box.
Install new wide loop vehicle detectors per Wide Loop Detail on ITO 6 and Standard Specifications.
Install new Modified Wide Loop vehicle detectors in speed -trap configuration per Details on ITD 6,
ITD 7, ITD 8 and Standard Specifications.
T- 26902C
FILE NArE e. e[IWBa1BTJYBWB°mae13891BTJYBW]
M T8 4BBA0 n
1 aE 2
e8 �r
+
°d�eyse R''
,.
E � •'w 2e
".'' e i
6
�1 q`
405 r Program
, �,�
ry xx
„-PRQL
NSrROCf1aN, INC
1 -405
1 -5 TO SR169
STAGE 1 - WIDENING
ITS NOTES
TIDE Ill AN
16B°'^ "`
FEO.AID PROJ.NO.
1D WAS
PLATTED BY ktlx
DESIGNED BY R.JAl
As BUNT
Ilan°
xe
s •�
ENIFJiEO W L CNAN
IFC
N16AN
RI
F
CHECIED BY K WOOEN
NmC b - REVNIDXS
B4rlllaa
RJ
wmwcr io.
C- 7295
uc mx xw
ENBR LNOOGSON
BBpEp AT BI°K
pYON°
RI
REDIOxAI ADII. O. DYE
PEVIBION
DATE