HomeMy WebLinkAboutT-26910C/1
F,klvun m Lon
RUN
EXISTING
CONDUIT
NEW
CONDUIT
INNERDUCT
EXISTING
CONDUCTOR
NEW
CONDUCTOR
REMARKS
1
3"
RUN
2 -25TWP
CONDUIT
REMOVED BY OTHERS
CONDUCTOR
1 -6TWP
REMOVED BY OTHERS
10
1- 36SMFO
2"
INSTALLED BY OTHERS
1- 24SMFO
-6SMFO
REMOVE
11
205"
1- 36SMFO
VIDEO /DATA DISTRIBUTION
1"
2C(SH)
1 -6SMFO
DETECTOR LEAD -INS
REMOVE
1- 12SMFO
DATA LATERAL
2
3"
SIGNALS
3- 2C(SH)
DETECTOR LEAD -INS
2 -25TWP
OPTICOM
REMOVED BY OTHERS
3 °'
DETECTOR
1 -6TWP
REMOVED BY OTHERS
1- 36SMFO
1
INSTALLED BY OTHERS
DATA LATERAL
12
1- 24SMFO
3"
REMOVE
1 -6SMFO
1
REMOVE
DATA LATERAL (INSTALL WHERE SPACE)
13
1- 36SMFO
VIDEO /DATA DISTRIBUTION
1- 12SMFO
DATA LATERAL
3
3"
3"
2 -25TWP
REMOVED BY OTHERS
2C(SH)
1- 36SMFO
REMOVE
INSTALLED BY OTHERS
1 -6TWP
REMOVED BY OTHERS
6-
1- 24SMFO
DETECTOR LEAD -INS
REMOVED
4"
1 -6SMFO
A
REMOVED
24SMFO
1- 36SMFO
VIDEO /DATA DISTRIBUTION
1- 12SMFO
DATA LATERAL
4
105"
REMOVED BY OTHERS
1 -6TWP
REMOVED BY OTHERS
C
1 -6SMFO
-25TWP
REMOVE
REMOVED BY OTHERS
1- 12SMFO
DATA LATERAL
5
3"
2- 2C(SH)
36SMFO
REMOVE UNUSED DETECTOR LEAD -INS
4"
4- 2C(SH)
DETECTOR LEAD -INS FINAL INSTALLED
1-
48SMFO
1 -6TWP
REMOVED BY OTHERS
1 -6SMFO
REMOVE
1- 12SMFO
DATA LATERAL INTERIM INSTALLED
6
2
4"
5- 2C(SH)
1-
REMOVE UNUSED DETECTOR LEAD -INS
REMOVE
4- 2C(SH)
DETECTOR LEAD -INS FINAL INSTALLED
1 -6TWP
1-
REMOVED BY OTHERS
1 -6SMF0
REMOVE
C
1- 12SMFO
DATA LATERAL INTERIM INSTALLED
7
3"
REMOVE
5- 2C(SH)
REMOVE UNUSED DETECTOR LEAD -INS
D
1 -6TWP
1-
REMOVED BY OTHERS
VIDEO /DATA DISTRIBUTION
1 -6SMF0
4"
REMOVE
A
1-
48SMFO
1- 12SMFO
DATA LATERAL INTERIM INSTALLED
INSTALLED BY OTHERS
1 -6SMFO
DATA LATERAL FINAL INSTALLED
B 9 C 9 D
6- 2C(SH)
DETECTOR LEAD -INS FINAL INSTALLED
8
17
2'°
3"
2- 2C(SH)
DETECTOR LEAD -INS
9
2 "
REMOVE UNUSED DETECTOR LEAD -INS
4- 2C(SH)
DETECTOR LEAD -INS
EXISTING
NEW
EXISTING
NEW
RUN
CONDUIT
CONDUIT
INNERDUCT
CONDUCTOR
CONDUCTOR
REMARKS
10
2"
1
-6SMFO
DATA LATERAL
11
205"
4-
2C(SH)
DETECTOR LEAD -INS
3 -5C
SIGNALS
1-
OPTICOM
DETECTOR
1
-6SMFO
DATA LATERAL
12
3"
1
-6SMFO
DATA LATERAL (INSTALL WHERE SPACE)
13
NOT USED
14
3"
6-
2C(SH)
REMOVE
6-
2C(SH)
DETECTOR LEAD -INS
15
4"
A
1-
24SMFO
REMOVE
B
1-
12MMFO
REMOVED BY OTHERS
C
1
-25TWP
REMOVED BY OTHERS
D
1-
36SMFO
VIDEO /DATA DISTRIBUTION
4"
A
1-
48SMFO
INSTALLED BY OTHERS
B 9 C 9 D
EMPTY
16
4"
A
1-
24SMFO
REMOVE
B
1-
12MMFO
REMOVED BY OTHERS
C
1
-25TWP
REMOVE
D
1-
36SMFO
VIDEO /DATA DISTRIBUTION
4"
A
1-
48SMFO
INSTALLED BY OTHERS
B 9 C 9 D
EMPTY
17
3"
10-
2C(SH)
REMOVE UNUSED DETECTOR LEAD -INS
6-
2C(SH)
DETECTOR LEAD -INS
18
4"
A
1- 24SMFO
REMOVE
B
1-
12MMFO
REMOVE
C
1
-25TWP
REMOVE
D
1-
36SMFO
VIDEO /DATA DISTRIBUTION
4"
A
1-
48SMFO
INSTALLED BY OTHERS
B9C9D
EMPTY
19
3"
10-
2C(SH)
REMOVE UNUSED DETECTOR LEAD -INS
4- 2C(SH)
DETECTOR LEAD -INS
20
3"
2
-25TWP
REMOVE
2-
36SMFO
VIDEO /DATA DISTRIBUTION
21
3"
14-
2C(SH)
DETECTOR LEAD -INS
2"
2-
36SMFO
VIDEO /DATA DISTRIBUTION
22
2"
1 -CCC
CAMERA CONTROL CABLE
23
2"
2 - #8
POWER TO CABINET
24
2"
2-
SERIAL
INSTALLED BY OTHERS
2 -CAT6 OSP
INSTALLED BY OTHERS
4-
2C(SH)
TOLL DETECTOR LEAD -INS
25
2"
1 -3C
ENFORCEMENT SIGNAL
2 - #8
POWER TO READER