HomeMy WebLinkAboutT-26910D11
RUN
EXISTING
CONDUIT
NEW
CONDUIT
INNERDUCT
EXISTING
CONDUCTOR
NEW
CONDUCTOR
REMARKS
26
RUN
3"
CONDUIT
CONDUIT
2— SERIAL
INSTALLED BY OTHERS
CONDUCTOR
REMARKS
41
2 —CAT6 OSP
INSTALLED BY OTHERS
2 °`
2- 36SMFO
VIDEO /DATA DISTRIBUTION
4- 2C(SH)
TOLL DETECTOR LEAD —INS
2"
VIDEO /DATA DISTRIBUTION
SPARE
27
SAME
CONDUITS
AS SHOWN
IN NOTE 8
ON ILT1
2"
SPARE
480 VAC
SEE ILT1 FOR ADDITIONAL CONDUCTORS
2"
2 — #8
POWER TO READER
DETECTOR LEAD —INS
1 -3C
ENFORCEMENT SIGNAL
2"
2- 36SMFO
VIDEO /DATA DISTRIBUTION
SPARE
28
2'°
2"
2— SERIAL
INSTALLED BY OTHERS
2 —CAT6 OSP
INSTALLED BY OTHERS
NOT USED
2- 36SMFO
VIDEO /DATA DISTRIBUTION
2
2"
4- 2C(SH)
TOLL DETECTOR LEAD —INS
2"
SPARE
29
POWER TO VMS
2"
2- 36SMF0
VIDEO /DATA DISTRIBUTION
2"
NOT USED
46
EMPTY
30
4- 2C(SH)
DETECTOR LEAD —INS
47
NOT USED
31
3"
2- 2C(SH)
POWER TO VMS
REMOVE UNUSED DETECTOR LEAD —INS
2"
4- 2C(SH)
DETECTOR LEAD —INS FINAL INSTALLED
32
3"
49
10- 2C(SH)
3'°
REMOVE UNUSED DETECTOR LEAD —INS
10- 2C(SH)
DETECTOR LEAD —INS
4- 2C(SH)
DETECTOR LEAD —INS INTERIM INSTALLED
3"
4- 2C(SH)
DETECTOR LEAD —INS FINAL INSTALLED
33
3"
1o5"
2 -25TWP
REMOVE
3 — #8
POWER TO VMS CABINET
2- 36SMFO
VIDEO /DATA DISTRIBUTION
VMS CABLES
VMS CONTROL CABLES TO SIGN
34
3"
105"
6 -2C(S H
3 — #8
DETECTOR LEAD —INS
POWER TO ES CABINET
4- 2C(SH)
DETECTOR LEAD —INS INTERIM INSTALLED
3 — #8
4- 2C(SH)
DETECTOR LEAD —INS FINAL INSTALLED
35
3"
12- 2C(SH)
3 — #4
REMOVE UNUSED DETECTOR LEAD —INS
53
3"
4- 2C(SH)
DETECTOR LEAD —INS INTERIM INSTALLED
12- 2C(SH)
REMOVE UNUSED DETECTOR LEAD —INS
4- 2C(SH)
DETECTOR LEAD —INS FINAL INSTALLED
3
2 -25TWP
4- 2C(SH)
REMOVE
2- 36SMFO
VIDEO /DATA DISTRIBUTION
4- 2C(SH)
DETECTOR LEAD -INS FINAL INSTALLED
VMS CABLES
VMS CONTROL CABLES TO SIGN
36
3"
2 -25TWP
COMMUNICATIONS TO ES CABINET
REMOVE
3"
2- 36SMFO
VIDEO /DATA DISTRIBUTION
DETECTOR LEAD —INS
VMS CABLES
VMS CONTROL CABLES TO SIGN
1 —CAT6 OSP
COMMUNICATIONS TO ES CABINET
37
105"
2"
4 —FOPC
FIBER OPTIC PATCH CORDS
38
2"
2"
1 —CAT6 OSP
COMMUNICATIONS TO VMS
39
VMS CONTROL CABLES TO SIGN
2"
VMS CABLES
VMS CONTROL CABLES TO SIGN
40
2"
56
4- 2C(SH)
DETECTOR LEAD —INS
2"
3 — #4
POWER TO VMS
SPARE
FILE NAME
TIME
DATE
PLOTTED BY
DESIGNED BY
ENTERED BY
CHECKED BY
PROJ. ENGR.
REGIONAL ADM.
C:XWorkiProjectY
4:29:05 PM
8/12/2010
dlo
R. JAHNS
L. CHAN
M. MADDEN
L.HODGSON
D. DYE
JV0002Xdms02268XBTJV0002 NT IT 167- AB.dan
AS -BUILT
NDC -34 CAMERA POLEITRANSFORMER RELOCATE
IFC
REVISION
REGION STATE FED.AID PROJ.NO.
NO.
10 WAS
JOB NUMBER
716110 MS
04123/08 RJ CONTRACT NO. LOCATION NO.
1213107 RJ C-7295
DATE BY
w Le-A
ov Wesgl��
���� 8 5
�s s T
sIONAL
P.E. STAMP BOX
DATE
�M. Jl eV0
oF�-w-q�sy�2 ,�'�i
EXISTING
NEW
EXISTING
NEW
RUN
CONDUIT
CONDUIT
INNERDUCT
CONDUCTOR
CONDUCTOR
REMARKS
41
2 °`
4- 2C(SH)
DETECTOR LEAD —INS
2"
2- 36SMFO
VIDEO /DATA DISTRIBUTION
2"
SPARE
42
2"
6 -2C(S H
DETECTOR LEAD —INS
2- 36SMFO
VIDEO /DATA DISTRIBUTION
2'°
SPARE
43
NOT USED
44
2
480VAC
SEE IL SHEETS FOR ADDITIONAL CONDUCTORS
3 — #4
POWER TO VMS
45
NOT USED
46
3"
4- 2C(SH)
DETECTOR LEAD —INS
47
2"
3 — #4
POWER TO VMS
48
2"
480VAC
SEE IL SHEETS FOR ADDITIONAL CONDUCTORS
49
3'°
10- 2C(SH)
DETECTOR LEAD —INS
50
3"
2- 36SMFO
VIDEO /DATA. DISTRIBUTION
51
1o5"
3 — #8
POWER TO VMS CABINET
3 — #4
POWER TO VMS
52
105"
3 — #8
POWER TO ES CABINET
3 — #8
POWER TO VMS CABINET
3 — #4
POWER TO VMS
53
3"
12- 2C(SH)
REMOVE UNUSED DETECTOR LEAD —INS
4- 2C(SH)
DETECTOR LEAD —INS INTERIM INSTALLED
4- 2C(SH)
DETECTOR LEAD -INS FINAL INSTALLED
2"
1 —CAT6 OSP
I
COMMUNICATIONS TO ES CABINET
54
3"
12- 2C(SH)
DETECTOR LEAD —INS
4- 2C(SH)
DETECTOR LEAD —INS
2"
SPARE
55
2"
VMS CABLES
VMS CONTROL CABLES TO SIGN
2"
SPARE
56
2"
3 — #4
POWER TO VMS
2"
SPARE
57
2
1 -6SMFO
DATA LATERAL
2"
SPARE
58
2"
480VAC
SEE IL SHEETS FOR ADDITIONAL CONDUCTORS
2"
114-2C(SH)
SPARE
59
3"
DETECTOR LEAD —INS
2"
2- 36SMFO
VIDEO /DATA DISTRIBUTION
2"
SPARE
60
2"
8- 2C(SH)
DETECTOR LEAD —INS
2"
SPARE
ov Wesgl��
���� 8 5
�s s T
sIONAL
P.E. STAMP BOX
DATE
�M. Jl eV0
oF�-w-q�sy�2 ,�'�i